Verona VEFSGE 304 SC manual Installation, Proximity to Side Cabinets

Page 6

1

3”

 

(76 mm)

 

MIN 35” 21/32 (905.5 mm)

 

MAX 36” 11/32 (923 mm)

24”

 

13/64mm)

 

(614.

 

 

9

 

 

Fig. 1.1

installation

PROXIMITY TO SIDE CABINETS

1.This range may be installed directly adjacent to existing 36” (914 mm) high base cabinets.

Range dimensions:

• width: 29” 7/8 (759 mm)

• depth: 24” 13/64 (614.9 mm)

• height (without backguard): MIN 35” 21/32 (905.5 mm) - MAX 36” 11/32 (923 mm)

• backguard (height): 3” (76 mm)

 Gas line opening: Wall - 37/64” (14.5 mm) from the right side to centre of range; from 5” 7/16 (138 mm) to 6” 1/8 (155.5 mm) [depending on feet regulation] from the floor.

Grounded outlet: should be located 37/64” (14.5 mm) from the left side

 

 

to centre of range; from 5” 7/16 (138 mm) to 6” 1/8 (155.5 mm) [depen-

 

 

ding on feet regulation] from the floor.

 

2.

The range CANNOT be installed directly adjacent to sidewalls, tall cabi-

 

 

nets, tall appliances, or other side vertical surfaces above 36” (914 mm)

 



high.

29” 7/8

There must be a minimum of 11” 13/16 (300 mm) side clearance from the

 

range to such combustible surfaces TO THE LEFT or TO THE RIGHT

(759 mm)

 

 

above the 36” (914 mm) high countertop.

 

 

IMPORTANT: One side (left or right) above the 36” (914 mm) high countertop must always be kept clear.

Island installation: There must be a minimum of 12” (305 mm) clearan- ce from the rear of the backguard to such combustible surface on the back of the range above the 36” (914 mm) high countertop.

3.The maximum upper cabinet depth recommended is 13” (330 mm). Wall cabinet above the range must be a minimum of 30” (762 mm) above the countertop for a width of minimum 30” (762 mm): it has to be centered with the range. Side wall cabinets above the range must be a minimum of 18” (457 mm) above the countertop.

6

Image 6
Contents GAS/ELECTRIC Range What to do if YOU Smell GAS Data Plate Conversion Label Installation Instructions Replacement Parts Electrical Grounding InstructionsInstallation Proximity to Side CabinetsIt is mandatory to install the backguard Assembling the BackguardProximity to Side Cabinets Standard Installation Proximity to Side Cabinets Island Installation ANTI-TIP Stability Device Installation Instructions Levelling the RangeInstalling the Cooktop Front Guard Manual Shut-off Valve fig Pressure RegulatorExplosion Hazard Pressure Regulator Installation Step GAS Connection Speficication Leak Testing Flexible ConnectionsRigid Pipe Connections Setting the Pressure Regulator To set the pressure regulator figOperations to be Performed When Substituting the Injectors Injectors TableSetting the Burner Minimum Semirapid burnerElectrical Connection with Power Cord Electrical RequirementsElectrical Connection with Conduit Wire Power Cord Installation See Figure =1 9/64 29 mm =7/8 22.5 mm Power CordWire Conduit Installation See Figure Plug the terminal holes of conductorsWiring Diagram Electric Diagram KEY