Verona VEFSGE 304 SC Wire Conduit Installation See Figure, Plug the terminal holes of conductors

Page 21

3-Wire Conduit Installation (See Figure 3.5)

1.Remove the Terminal Block Access Plate on the back of the range by unscrewing the 4 fixing Screws (Figure 3.4).

2.Check the correct positioning of the Conduit Bracket as per figure 3.5.

3.Feed 1/2” (1.3 cm) trade size Conduit through the hole in the

Conduit Bracket and secure to the Conduit Bracket with a Conduit Clamp.

4.Plug the terminal holes of conductors.

The Neutral or Ground Wire must be connected to the neutral terminal located in the center of Terminal Block.

The Power Wires must be connected to the outside terminals.

5.Plug washers and tighten nuts securely.

 Do not remove Ground strap.

6.Reassemble the Terminal Block Access Plate on the back of the range by screwing the 4 fixing Screws (Figure 3.4).

4-Wire Conduit Installation (See Figure 3.6)

1.Remove the Terminal Block Access Plate on the back of the range by unscrewing the 4 fixing Screws (Figure 3.4).

2.Check the correct positioning of the Conduit Bracket as per figure 3.6.

3.Feed 1/2” (1.3 cm) trade size Conduit through the hole in the

Conduit Bracket and secure to the Conduit Bracket with a Conduit Clamp.

4.Remove the 3 wire terminal nuts and washers from the Termi- nal Block.

5.Remove the Ground Strap from the frame of range and termi- nal by removing its screw and cutting it as shown in Figure 3.6.

6.Plug the terminal holes of conductors.

The Neutral Wire must be connected to the neutral terminal located in the center of Terminal Block; the Power Wires must be connected to the outside terminals; the Ground Wire must be attached to the frame of range by using the (Ground) identi-

fied Grounding Screw.

3

Fig. 3.4

Screws

Screws

Terminal Block

Access Plate

Fig. 3.5

 

 

 

Ground strap

 

Neutral Wire

Terminal Block

A

Power Cord

 

Bracket

 

 

 

 

B

 

A: D=1” 9/64 (29 mm)

 

B: D=7/8” (22.5 mm)

 

 

Conduit Clamp

Power Wires

 

Conduit

 

 

Fig. 3.6

Cut Ground Strap

7.Plug washers and tighten nuts securely.

8.Reassemble the Terminal Block Access Plate on the back of the range by screwing the 4 fixing Screws (Figure 3.4).

Neutral Wire

APower Cord

Bracket

B

A: D=1” 9/64 (29 mm)

B: D=7/8” (22.5 mm)

Terminal Block

Grounding

Screw

Power Wires

 

Grounding Wire

 

 

 

Conduit

Conduit Clamp

 

 

 

 

21

 

 

 

 

 

 

 

 

Image 21
Contents GAS/ELECTRIC Range What to do if YOU Smell GAS Data Plate Conversion Label Installation Instructions Electrical Grounding Instructions Replacement PartsProximity to Side Cabinets InstallationAssembling the Backguard It is mandatory to install the backguardProximity to Side Cabinets Standard Installation Proximity to Side Cabinets Island Installation Levelling the Range ANTI-TIP Stability Device Installation InstructionsInstalling the Cooktop Front Guard Manual Shut-off Valve fig Pressure RegulatorExplosion Hazard Pressure Regulator Installation Step GAS Connection Speficication Leak Testing Flexible ConnectionsRigid Pipe Connections To set the pressure regulator fig Setting the Pressure RegulatorInjectors Table Operations to be Performed When Substituting the InjectorsSemirapid burner Setting the Burner MinimumElectrical Connection with Power Cord Electrical RequirementsElectrical Connection with Conduit =1 9/64 29 mm =7/8 22.5 mm Power Cord Wire Power Cord Installation See FigurePlug the terminal holes of conductors Wire Conduit Installation See FigureElectric Diagram KEY Wiring Diagram