Moyer Diebel MH-60M3, MH-6NM3, MH-6LM3 technical manual Deliming

Page 26

CLEANING

DELIMING

Your dishwasher should be delimed regularly depending on the mineral content of your water. Inspect the machine interior for mineral deposits and use a deliming solution for the best cleaning results.

NOTE:

Consult your chemical supplier for an appropriate deliming solution.

!WARNING:

Deliming solutions or other acids must not come in contact with household bleach (sodium hypochlorite) or any chemicals containing chlorine, iodine, bromine, or fluorine. Mixing will cause hazardous gases to form.

Skin contact with deliming solutions can cause severe irritation and possible chemical burns. Consult your chemical supplier for specific safety precautions.

DELIMING PROCESS

Model MH-60 and MH-6N

1.Remove all dishes from machine.

2.Remove any chemical pick-up tubes from their containers.

3.Place each tube in a container of fresh water and prime the chemical lines for several minutes to thoroughly flush chemical from the lines. Leave pick-up tubes out of their containers.

4.Drain the machine and refill with fresh water.

5.Spray interior walls with delimimg solution and let sit for 5 or 10 minutes depending on amount of build-up. Add deliming solution to wash tank.

Do not let chemicals sit for longer than 15 minutes.

6.Close the doors to run an automatic cycle.

7.Repeat Steps 4-6 if necessary.

8.Lift the drain lever assembly and drain the machine.

9.Refill the machine and run a complete cycle two additional times. Drain and refill the ma- chine after each cycle to thoroughly flush any deliming solution from the interior of the machine.

10.Flip the power switch to OFF.

11.Drain machine.

12.Deliming is complete.

24

Image 26
Contents MH-6NM3 MH-6LM3Moyer Diebel, US Moyer Diebel, Limited Revision History CommentsContents List of Figures Limited Warranty Introduction Welcome to Moyer DiebelOptions MH-60 only AccessoriesStandard Equipment includes Model Installation Unpack the dishwasherPlacement for Corner Operation Installation Electrical ConnectionsHinged Control Panel Installation 20-22 PSI/138-151.8 kPaVentilation Water ConnectionsDrain Connections Chemical Dispenser Signal Terminal Block Chemical ConnectionsMH-6L Only MH-60, 6NMH-60, 6N, 6L Models MH-60 and MH-6N do not require sanitizerComplete the installation Initial START-UPCheck Wash Water Temperature Initial START-UPPower Check Final Rinse Water Temperature Check Final Rinse Water PressureDrain the dishwasher Extended Wash OperationComplete the initial start-up Initial START-UP Operation Summary Action ResultEvery 8 Hours or at the End of the Day CleaningEvery 2 Hours or After Each Meal Period Deliming Troubleshooting Condition Cause SolutionTroubleshooting Schematics Basic ServiceTroubleshooting ToolsElectrical Service Motor OverloadsElectrical Service Timers Cycle TimerConfiguration a Electrical Service Motor Connections LineMechanical Service Pump Seal ReplacementReplacement Parts MH-60/6N/6L Doors and Panels Doors and Panels Part Item No Part DescriptionMH-60/6N/6L Door Guides, Stops, and Lift Bracket Door GUIDES, STOPS, and Lift Bracket Part Item No Part Description QtyMH-60/6N/6L Door Handle, Spring Assembly, and Safety Switch Door HANDLE, Spring ASSEMBLY, and Safety Switch BUSHING, Side DoorMH-60/6N/6L Track Assembly Corner configuration shown Track Assembly GUIDE, Left HandFront Side Left WASH/RINSE Spray Piping MH-60/6N/6L Wash/Rinse Spray Arms WASH/RINSE Spray Arms MH-60/6N/6L Drain Assembly and Scrap Screens Drain Assembly and Scrap Screens RETAINER, OverflowMH-60/6N/6L Wash Tank Heat and Thermostats Wash Tank Heat and Thermostats WASHER, Lock 1/4 Split SSTValve Fill From Piping MH-60 only Electric Booster and Thermostats WASHER, Lock 1/4 SplitTo Upper MH-60 only Lower Fill Piping Assembly Replacement Parts Water in from Lower Piping MH-60/6N only Upper Fill Piping Assembly Customer Water MH-6N/6L only Lower Fill Piping Assembly MH-6L Only Upper Fill Piping Assembly MH-6L only Upper Fill Piping Assembly MH-60/6N/6L Pump Assembly Pump Assembly Backing PLATE, MachinedMH-60/6N/6L Control Panel and Gauges Control Panel and Gauges MH-60/6N/6L Control Cabinet Control Cabinet Dishracks and PRV Dishracks and PRV Part Part Description Item NoThis Intentionally Left Blank Electrical Schematic / 3 Phase MH-60, 6N, 6L Electrical Schematic / 1 Phase MH-60, 6N, 6L