GENERAL
Electrical Power Requirements:Fig Electric Heat/Electric Booster
Model | Voltage | Booster Rise | Machine | Power Requirement |
|
| Full Load Amps | (125% Service Factor) | |
115/60/1 | — | 48 Amps | 60 Amps | |
208/60/1 | — | 23 Amps | 29 Amps | |
220/60/1 | — | 23 Amps | 29 Amps | |
230/60/1 | — | 23 Amps | 29 Amps | |
240/60/1 | — | 24 Amps | 30 Amps | |
208/60/3 | — | 12 Amps | 15 Amps | |
220/60/3 | — | 13 Amps | 16 Amps | |
230/60/3 | — | 13 Amps | 16 Amps | |
240/60/3 | — | 13 Amps | 16 Amps | |
380/60/3 | — | 7 Amps | 9 Amps | |
415/60/3 | — | 8 Amps | 10 Amps | |
480/60/3 | — | 6 Amps | 8 Amps | |
575/60/3 | — | 5 Amps | 6 Amps | |
|
|
|
|
|
115/60/1 | — | — | — | |
208/60/1 | 40°F/23°C | 59 Amps | 74 Amps | |
220/60/1 | 40°F/23°C | 61 Amps | 76 Amps | |
230/60/1 | 40°F/23°C | 63 Amps | 79 Amps | |
240/60/1 | 40°F/23°C | 65 Amps | 81 Amps | |
208/60/3 | 40°F/23°C | 33 Amps | 41 Amps | |
220/60/3 | 40°F/23°C | 35 Amps | 44 Amps | |
230/60/3 | 40°F/23°C | 36 Amps | 45 Amps | |
240/60/3 | 40°F/23°C | 37 Amps | 46 Amps | |
380/60/3 | 40°F/23°C | 20 Amps | 25 Amps | |
415/60/3 | 40°F/23°C | 20 Amps | 25 Amps | |
480/60/3 | 40°F/23°C | 17 Amps | 21 Amps | |
575/60/3 | 40°F/23°C | 14 Amps | 18 Amps | |
|
|
|
|
|
115/60/1 | — | — | — | |
208/60/1 | — | — | — | |
220/60/1 | — | — | — | |
230/60/1 | — | — | — | |
240/60/1 | — | — | — | |
208/60/3 | 70°F/39°C | 50 Amps | 63 Amps | |
220/60/3 | 70°F/39°C | 52 Amps | 65 Amps | |
230/60/3 | 70°F/39°C | 54 Amps | 68 Amps | |
240/60/3 | 70°F/39°C | 56 Amps | 70 Amps | |
380/60/3 | 70°F/39°C | 30 Amps | 38 Amps | |
415/60/3 | 70°F/39°C | 33 Amps | 41 Amps | |
480/60/3 | 70°F/39°C | 28 Amps | 35 Amps | |
575/60/3 | 70°F/39°C | 23 Amps | 29 Amps |
7