Moyer Diebel MH-60M3, MH-6NM3, MH-6LM3 technical manual Electrical Schematic / 3 Phase MH-60, 6N, 6L

Page 71

PER LOCAL ELECTRICAL CODE TO CUSTOMERS DISCONNECT SWITCH

L1 L2 L3 N

See NOTE 1

3

GND

L3

L2

L1

FU1FU2

910

T1

120V

1

2

 

 

 

NOTE 1: N is used only on

 

 

Wye connected supplies

 

 

(3 Phase 4 Wire Systems)

7

 

 

 

 

R1A

 

 

 

 

8

 

 

 

 

 

MPS

 

1

2

L1 L2 L3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

OFF

1

 

 

 

 

 

 

TR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cycle = 60 secs.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1MOL

1M 20

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

6

DR1

 

 

 

 

 

 

 

34

 

 

 

 

 

 

 

 

 

 

 

4

 

4

 

 

 

 

 

 

 

0

10

20

30

40

50

60

70

80

90

 

7

 

 

 

 

 

 

 

35

21

 

 

 

 

 

 

 

 

 

 

1MTR

 

 

 

TIMER MOTOR

 

 

 

 

 

 

 

 

 

 

 

LT1

 

 

36

22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R2A

 

 

 

 

 

 

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

2

3KW ELECTRIC TANK HEAT (IF USED)

TRA NC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FU3

HC1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T2

 

37

23

 

0

10

20

30

40

50

60

70

80

90

 

 

 

 

 

 

 

 

FU4

 

 

 

 

R2B

 

 

24V

 

 

38

24

 

 

 

 

 

HOMING CYCLE CAM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FU5

39

25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

 

 

 

 

 

3KW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DSS

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

41

 

43

 

 

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

42

DR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TRB NC

 

Wash = 45 secs.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R3A

11

 

 

 

 

 

 

FOR 3 PHASE DELTA CONNECTION

0

10

20

30

40

50

60

70

80

90

7

11

 

 

 

11

R2

2

 

 

 

 

 

 

 

(TRC Not Used)

 

 

WASH CYCLE CAM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HC1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FU3

37

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

23

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

 

16

 

 

FU4

38

 

24

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R3

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FU5

39

25

3KW

TRD NC

 

Rinse = 14 secs.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FTRA

 

 

 

 

 

 

 

 

 

 

 

0

10

20

30

40

50

60

70

80

90

7

NC

17

17

 

17 FTR

 

2

 

 

 

 

 

 

 

 

RINSE CYCLE CAM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

NO

 

 

 

 

 

 

FOR 3 PHASE WYE CONNECTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17

R2C

 

 

 

9KW ELECTRIC BOOSTER HEAT (IF USED)

FTR

 

 

 

 

 

 

 

 

 

 

 

 

 

16

 

18

R1

 

2

BC1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

26

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18

 

 

 

 

18

 

 

 

 

 

 

27

 

0

10

20

30

40

50

60

70

80

90

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

28

9KW

 

 

 

 

FILL TIMER MOTOR

 

 

 

 

 

 

 

R1B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TSHC

ELECTRIC HEAT ONLY

 

 

 

 

 

NO

 

Timed Fill = 90 secs.

 

 

 

 

 

6

 

 

 

19

12

HCHL

13 HC1

2

 

 

 

 

FTRA NC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FOR 3 PHASE DELTA CONNECTION

0

10

20

30

40

50

60

70

80

90

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BC126

 

 

FILL TIMER CAM

 

 

7

 

19

TSBC

ELECTRIC HEAT ONLY

2

27

 

1M

Wash Motor Contactor

 

 

 

 

 

 

14

BCHL

15

BC1

28

 

 

 

 

 

 

 

 

 

 

 

 

 

9KW

1MOL

Wash Motor Overload

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1MTR

Wash Motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

BC1

Booster Tank Contactor or Steam Valve

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BCHL

Booster Tank High Limit (ELECTRIC HEAT ONLY)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FOR 3 PHASE WYE CONNECTION

DR

Door Safety Switch Relay

 

 

 

2

 

 

 

 

 

 

 

 

 

DSS

Door Safety Switch

 

 

 

 

 

 

 

 

EWS

 

 

 

 

18KW ELECTRIC BOOSTER HEAT (IF USED)

EWS

Extended Wash Switch

 

 

 

 

 

 

 

 

 

 

 

 

FTR

Fill Timer Motor

 

 

 

 

 

 

 

 

 

 

 

 

BC126

 

 

18

 

TR

31

 

31

 

 

 

 

 

 

 

FTRA

Fill Timer Cam

 

 

 

 

 

 

 

5

 

 

 

 

27

 

FU1 & 2

Transformer Fuses

 

 

 

 

 

 

 

 

 

 

 

 

 

FU3,4,5

Tank Heat Fuses

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LT2

 

28

18KW

HC1

Tank Heat Contactor or Steam Valve

 

 

7

NO TRA

5

 

 

5

 

 

 

 

2

 

 

HCHL

Tank Heat High Limit (ELECTRIC HEAT ONLY)

 

 

 

 

 

 

 

 

 

 

LT1

Power ON Light

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

6

NC

 

 

 

 

 

 

 

 

 

 

 

LT2

Cycle Light

 

 

 

 

 

 

 

 

 

 

 

 

 

MPS

Main Power Switch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1MOL

FOR 3 PHASE DELTA CONNECTION

R1

Fill Relay

 

 

8

TRB

 

 

 

 

 

1M

33

 

2

BC1

 

R2

Hold-In Relay

 

 

 

 

 

 

 

 

 

 

R3

Power-Up Relay

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

26

 

RWV

Rinse Water Valve

 

 

 

 

 

 

 

 

 

Detergent

 

2

27

 

 

 

 

 

 

 

 

 

 

 

 

T1

LINE:120V Transformer

 

 

 

 

 

 

 

 

 

Signal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

28

 

T2

120V:24V Transformer

 

 

 

 

 

R1C

 

 

 

 

 

 

 

18KW

 

18

18

NO TRD

29

30

 

 

 

 

 

2

TR

Timer Motor

 

 

 

Rinse Aid

 

 

DIAGRAM STATE

 

 

NC

 

 

 

 

 

 

 

 

 

TRA

Homing Cycle Cam

 

7

 

 

 

 

 

 

 

 

 

 

 

TRB

Wash Cycle Cam

END OF CYCLE

 

 

 

 

 

 

 

 

 

 

 

 

 

TRD

Rinse Cycle Cam

 

 

 

 

 

18

 

32

 

 

 

2

 

 

POWER - OFF

 

 

 

 

 

 

RWV

 

 

FOR 3 PHASE WYE CONNECTION

TSBC

Booster Tank Thermostat

DOOR - CLOSED

 

 

 

 

 

29

 

 

 

 

 

 

 

 

TSHC

Wash Tank Thermostat

 

18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B701477/A

Figure 39 - Electrical Schematic / 3 Phase (MH-60, 6N, 6L)

69

Image 71
Contents MH-6LM3 MH-6NM3Moyer Diebel, US Moyer Diebel, Limited Comments Revision HistoryContents List of Figures Limited Warranty Welcome to Moyer Diebel IntroductionOptions MH-60 only AccessoriesStandard Equipment includes Model Unpack the dishwasher InstallationPlacement for Corner Operation Electrical Connections InstallationHinged Control Panel 20-22 PSI/138-151.8 kPa InstallationVentilation Water ConnectionsDrain Connections Chemical Connections Chemical Dispenser Signal Terminal BlockModels MH-60 and MH-6N do not require sanitizer MH-60, 6NMH-60, 6N, 6L MH-6L OnlyInitial START-UP Complete the installationInitial START-UP Check Wash Water TemperaturePower Check Final Rinse Water Pressure Check Final Rinse Water TemperatureDrain the dishwasher Extended Wash OperationComplete the initial start-up Initial START-UP Action Result Operation SummaryEvery 8 Hours or at the End of the Day CleaningEvery 2 Hours or After Each Meal Period Deliming Condition Cause Solution TroubleshootingTroubleshooting Tools Basic ServiceTroubleshooting SchematicsMotor Overloads Electrical ServiceCycle Timer Electrical Service TimersConfiguration a Line Electrical Service Motor ConnectionsPump Seal Replacement Mechanical ServiceReplacement Parts MH-60/6N/6L Doors and Panels Part Item No Part Description Doors and PanelsMH-60/6N/6L Door Guides, Stops, and Lift Bracket Part Item No Part Description Qty Door GUIDES, STOPS, and Lift BracketMH-60/6N/6L Door Handle, Spring Assembly, and Safety Switch BUSHING, Side Door Door HANDLE, Spring ASSEMBLY, and Safety SwitchMH-60/6N/6L Track Assembly Corner configuration shown GUIDE, Left Hand Track AssemblyFront Side Left WASH/RINSE Spray Piping MH-60/6N/6L Wash/Rinse Spray Arms WASH/RINSE Spray Arms MH-60/6N/6L Drain Assembly and Scrap Screens RETAINER, Overflow Drain Assembly and Scrap ScreensMH-60/6N/6L Wash Tank Heat and Thermostats WASHER, Lock 1/4 Split SST Wash Tank Heat and ThermostatsValve Fill From Piping WASHER, Lock 1/4 Split MH-60 only Electric Booster and ThermostatsTo Upper MH-60 only Lower Fill Piping Assembly Replacement Parts Water in from Lower Piping MH-60/6N only Upper Fill Piping Assembly Customer Water MH-6N/6L only Lower Fill Piping Assembly MH-6L Only Upper Fill Piping Assembly MH-6L only Upper Fill Piping Assembly MH-60/6N/6L Pump Assembly Backing PLATE, Machined Pump AssemblyMH-60/6N/6L Control Panel and Gauges Control Panel and Gauges MH-60/6N/6L Control Cabinet Control Cabinet Dishracks and PRV Part Part Description Item No Dishracks and PRVThis Intentionally Left Blank Electrical Schematic / 3 Phase MH-60, 6N, 6L Electrical Schematic / 1 Phase MH-60, 6N, 6L