Moyer Diebel MH-6NM3, MH-6LM3, MH-60M3 technical manual Electrical Schematic / 1 Phase MH-60, 6N, 6L

Page 72

PER LOCAL ELECTRICAL CODE TO CUSTOMERS DISCONNECT SWITCH

L1 N

3

GND

N

L1

FU1

FU2

9

10

T1

NOT USED IN

115V 1 PH.

 

SEE NOTE 1

 

120V

12

7

R1A

8

NOTE 1: IF SUPPLY IS 115 V 1 PH.,

T1 IS NOT USED. WIRES

#1 AND #2 ARE CONNECTED TO THE FUSE BLOCK.

 

 

 

 

 

 

 

MPS

 

 

 

1

2

L1

N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

OFF

1

 

 

 

 

 

 

 

 

 

 

 

TR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1MOL

 

1M 20

 

 

 

Cycle = 60 secs.

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

34

 

 

 

 

 

 

 

 

 

 

 

 

 

6

DR1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

4

 

 

 

 

 

 

 

 

 

 

 

 

 

0

10

20

30

40

50

60

70

80

90

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1MTR

 

 

 

 

 

TIMER MOTOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LT1

 

 

 

 

36

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

2

 

 

 

22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R2A

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3KW ELECTRIC TANK HEAT (IF USED)

 

TRA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

2

 

 

NC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FU3

HC1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

37

23

 

 

 

 

0

10

20

30

40

50

60

70

80

90

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HOMING CYCLE CAM

 

 

 

 

 

 

 

 

 

R2B

 

 

24V

 

 

 

 

FU5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

39

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

41

 

DSS

42

 

43

 

 

 

 

 

 

 

NO

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DR

 

 

 

 

 

3KW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TRB NC

 

Wash = 45 secs.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

R3A

 

11

 

 

 

 

11

 

 

2

 

 

 

 

 

 

 

0

10

20

30

40

50

60

70

80

90

 

 

11

 

 

 

 

 

R2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WASH CYCLE CAM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(TRC Not Used)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

 

 

 

16

 

 

 

 

9KW ELECTRIC BOOSTER HEAT (IF USED)

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R3

 

2

 

USED ONLY ON THE 208-240V MODELS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BC1 26

 

 

 

TRD NC

 

Rinse = 14 secs.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NC FTRA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

10

20

30

40

50

60

70

80

90

 

7

 

17

17

 

 

17

FTR

 

2

 

 

28

 

 

 

 

 

 

 

RINSE CYCLE CAM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9KW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R2C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18

 

 

2

 

 

 

 

 

 

FTR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

 

R1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18

 

 

 

 

 

 

 

 

18

 

 

 

 

 

 

 

 

 

 

 

0

10

20

30

40

50

60

70

80

90

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FILL TIMER MOTOR

 

 

 

 

 

 

 

 

R1B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TSHC

ELECTRIC HEAT ONLY

 

 

 

 

 

 

 

 

NO

 

Timed Fill = 90 secs.

 

 

 

 

 

 

6

 

 

 

 

 

19

 

 

12

HCHL

13

2

 

 

 

 

 

FTRA NC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HC1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

10

20

30

40

50

60

70

80

90

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FILL TIMER CAM

 

 

 

 

 

7

 

 

 

 

 

TSBC

ELECTRIC HEAT ONLY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

19

14

BCHL

15

2

 

 

 

 

 

 

 

1M

Wash Motor Contactor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BC1

 

 

 

 

 

 

 

 

1MOL

Wash Motor Overload

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1MTR

Wash Motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

BC1

Booster Tank Contactor or Steam Valve

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BCHL

Booster Tank High Limit (ELECTRIC HEAT ONLY)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DR

Door Safety Switch Relay

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DSS

Door Safety Switch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EWS

 

 

 

 

 

 

 

 

 

 

EWS

Extended Wash Switch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FTR

Fill Timer Motor

 

 

 

 

 

 

 

18

 

 

TR

 

31

 

 

31

 

 

 

 

 

 

 

 

 

 

 

 

FTRA

Fill Timer Cam

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

FU1 & 2 Transformer Fuses

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FU3,4,5

Tank Heat Fuses

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LT2

 

 

 

 

 

 

 

 

HC1

Tank Heat Contactor or Steam Valve

 

 

 

 

 

7

 

NO TRA

 

5

 

 

 

5

 

 

 

2

 

 

 

 

 

 

 

HCHL

Tank Heat High Limit (Electric Heat ONLY)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LT1

Power ON Light

 

 

 

 

 

 

 

6

6

 

NC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LT2

Cycle Light

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MPS

Main Power Switch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1MOL

 

 

 

 

 

 

 

R1

Fill Relay

 

 

 

 

 

 

 

 

8

 

TRB

 

 

 

 

 

 

 

1M

33

2

 

 

 

 

 

 

 

R2

Hold-In Relay

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R3

Power-Up Relay

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Detergent

2

 

 

 

 

 

 

 

RWV

Rinse Water Valve

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T1

LINE:120V Transformer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Signal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T2

120V:24V Transformer

 

 

 

 

 

 

 

 

 

 

 

 

 

R1C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18

18

 

NO TRD

 

29

 

30

 

Rinse Aid

2

 

 

 

 

 

 

 

TR

Timer Motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIAGRAM STATE

 

TRA

Homing Cycle Cam

 

 

 

 

 

 

 

7

 

NC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TRB

Wash Cycle Cam

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18

 

 

 

 

 

 

 

 

 

END OF CYCLE

 

 

TRD

Rinse Cycle Cam

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

32

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RWV

 

 

 

 

 

 

POWER - OFF

 

 

TSBC

Booster Tank Thermostat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

29

 

 

 

 

 

 

 

 

 

DOOR - CLOSED

 

 

TSHC

Wash Tank Thermostat

 

 

 

 

 

 

18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B701478/A

Figure 40 - Electrical Schematic / 1 Phase (MH-60, 6N, 6L)

70

Image 72
Contents MH-6NM3 MH-6LM3Moyer Diebel, US Moyer Diebel, Limited Revision History CommentsContents List of Figures Limited Warranty Introduction Welcome to Moyer DiebelAccessories Standard Equipment includesOptions MH-60 only Model Installation Unpack the dishwasherPlacement for Corner Operation Installation Electrical ConnectionsHinged Control Panel Installation 20-22 PSI/138-151.8 kPaWater Connections Drain ConnectionsVentilation Chemical Dispenser Signal Terminal Block Chemical ConnectionsMH-60, 6N MH-60, 6N, 6LMH-6L Only Models MH-60 and MH-6N do not require sanitizerComplete the installation Initial START-UPCheck Wash Water Temperature Initial START-UPPower Check Final Rinse Water Temperature Check Final Rinse Water PressureExtended Wash Operation Complete the initial start-upDrain the dishwasher Initial START-UP Operation Summary Action ResultCleaning Every 2 Hours or After Each Meal PeriodEvery 8 Hours or at the End of the Day Deliming Troubleshooting Condition Cause SolutionTroubleshooting Basic Service TroubleshootingSchematics ToolsElectrical Service Motor OverloadsElectrical Service Timers Cycle TimerConfiguration a Electrical Service Motor Connections LineMechanical Service Pump Seal ReplacementReplacement Parts MH-60/6N/6L Doors and Panels Doors and Panels Part Item No Part DescriptionMH-60/6N/6L Door Guides, Stops, and Lift Bracket Door GUIDES, STOPS, and Lift Bracket Part Item No Part Description QtyMH-60/6N/6L Door Handle, Spring Assembly, and Safety Switch Door HANDLE, Spring ASSEMBLY, and Safety Switch BUSHING, Side DoorMH-60/6N/6L Track Assembly Corner configuration shown Track Assembly GUIDE, Left HandFront Side Left WASH/RINSE Spray Piping MH-60/6N/6L Wash/Rinse Spray Arms WASH/RINSE Spray Arms MH-60/6N/6L Drain Assembly and Scrap Screens Drain Assembly and Scrap Screens RETAINER, OverflowMH-60/6N/6L Wash Tank Heat and Thermostats Wash Tank Heat and Thermostats WASHER, Lock 1/4 Split SSTValve Fill From Piping MH-60 only Electric Booster and Thermostats WASHER, Lock 1/4 SplitTo Upper MH-60 only Lower Fill Piping Assembly Replacement Parts Water in from Lower Piping MH-60/6N only Upper Fill Piping Assembly Customer Water MH-6N/6L only Lower Fill Piping Assembly MH-6L Only Upper Fill Piping Assembly MH-6L only Upper Fill Piping Assembly MH-60/6N/6L Pump Assembly Pump Assembly Backing PLATE, MachinedMH-60/6N/6L Control Panel and Gauges Control Panel and Gauges MH-60/6N/6L Control Cabinet Control Cabinet Dishracks and PRV Dishracks and PRV Part Part Description Item NoThis Intentionally Left Blank Electrical Schematic / 3 Phase MH-60, 6N, 6L Electrical Schematic / 1 Phase MH-60, 6N, 6L