Brown and Son WA Cooler & Freezer manual How To Call for Service Repair, Replacement Parts, Size

Page 17

How To Call for Service Repair

After your W. A. Brown & Son, Inc. Walk-in has been correctly installed, and the refrigeration system properly connect- ed your new Walk-in should provide you years of uninterrupted service. Should your Walk-In ever require service, please have the following information available upon initiating a service call.

Determine the date your walk-in was placed into service and enter it here. ______________________________

Locate the serial number located on the door of your unit and enter it here. ____________________________

Determine the dealer from whom you purchased your walk-in and enter it here. __________________________

Should you feel your Walk-in refrigeration system is not operating properly and your unit is covered under warranty, please contact W. A. Brown & Son, Inc. by calling 800-438-2316 and ask for Refrigeration Service. Provide the date your unit was installed for use and the serial number, along with the name of the dealer from which you purchased your unit. Describe the nature of the problem, and our qualified technicians will refer you to the appropriate trained servicer, or, you may use your preferred local refrigeration technician. See exact detail regarding labor warranty if you have purchased the optional one year labor warranty. Of course repairs that are covered under warranty will be handled at no charge to you. Expenses that result from calls not covered under warranty (such as fuses blown or a unit not plugged in) will be invoiced to the person asking for the service call.

Replacement Parts

For best operation, always use official replacement parts for items such as hinges, gaskets, and latches. These can be purchased directly from W. A. Brown by calling Service Parts at 800-640-0593 or visit us on the web at www.wabrown.com. Minimum orders and order handling charges may apply.

Replacement door latch keys are available at a minimum charge.

Data Plate - Located on inside of main door.

W.A. BROWN &B SON, INC.

Since 1910

Salisbury, NC

REFRIGERATION REQUIREMENTS

 

For Storage Temperature of 0

˚ F

 

Evaporator: 6578 BTU / HR at 10˚ TD

 

Condensing Unit: 6578

BTU / HR at -10 ˚

 

Suction Temperature.

in 100˚ Ambient

U® L

SERIAL NO. 98949-1D2

NSF

UL MODEL: UDS-4

LISTED 480E

SIZE: 9X13 04

 

 

 

COMPONENT

DOOR PANEL ASSEMBLY

 

120 V. A. C. 300 WATTS

Serial No. (5 digits w/dash for door number ex: 90117-1D2) (This number is the same as the Order Number)

Size

(Size of box and year mfg’d ex: 16X17-01)

UL Model (This number UDS-4 can not be used to identify order - it means there is 4" of urethane foamed in panels)

15

Image 17
Contents For All W. A. Brown & Son, Inc. Models Table of Contents Terminology Receiving and UncratingInstallation of floor panels Floor Preparation and InstallationDiamond Aluminum Treadplate Overlay Instructions Layout of the FloorFloor Spline Layout and Installation Cam Lock InstallationFloorless Walk-In Layout Ramset Studs Or ScrewsFigure #4 PVC Panel Track Installation for Floorless Walk-InWall Protector Plate Wainscotting Instructions Wall Panel InstallationMultiple Compartment Walk-Ins With a Tee Panel Top Panel InstallationPenetrations of Panels Installation of Membrane Roof Cap For Outside UnitsMembrane Roof Cap Install to existing wall Duro-LastRoof Cap Installation for outside installationPainting Fiber Cement Fiber Cement Finish Panels InstallationWhen ceiling is not Drop-Off Walk-In Coolers and Freezers Top Panel Trim InstallationInstallation of 1/2 x 5 Trim on Top Panels Installing the Refrigeration System EZ Pack Installation InstructionsSetting Controls Final Checks Before OperationWiring the Door Heater, Lights & Windows Roof Cap & Curb Installation Figure #14Vapor Proof Light Fluorescent LightsHousekeeping and Safety Recommendations Housekeeping and SafetyCleaning of Stucco Aluminum & Galvalume Plus Cleaning Stainless Steel FinishesSize How To Call for Service RepairReplacement Parts Lifetime Limited Cabinet Warranty Instructions for removing Door Leaf with Spring Adjusting Door Closer See Figure #17Loaded Hinges See Figure #15 See sketchDescription Of Numbered Door Section Components Replacement KeysDescription Of Numbered Parts in Figure #19 and #20 Guidelines For Replacing Door Heater CableDescription Of Numbered Parts in Figure #21 Relacing Door GasketCross Section Of Door Leaf Replacing Flush Dial Thermometer Installing Surface Dial Thermometer Figure #23Replacing a Pressure Relief Port Replacing The Digital ThermometerDescription Of Numbered Parts, Figure #24 and #25 Description Of Numbered Parts, Figure #27, and #28Figure #26 Electrical Hook-Up to Junction BoxFigure #30 Malfunction Possible Cause Solution Refrigeration Trouble Shooting GuideInput Voltage