Brown and Son WA Cooler & Freezer manual Guidelines For Replacing Door Heater Cable

Page 21

Guidelines For Replacing Door Heater Cable

If door jamb is sweating or icing, you need to use the following guidelines.

1.Check the circuit breaker to see if it is in the on position and functioning properly.

2.Check the heater cable (#1) for current at the junction box.

3.Turn the circuit breaker off that supplies electricity to the heater cable

4.Check the heater cable for continuity. If the circuit is open you will need to replace the heater cable.

5.Remove the screws (#10) from the threshold plate (#6) but DO NOT remove the threshold at this time.

6.Remove the screws (#7) from the stainless steel jamb/heater cover (#3).

7.Remove the stainless steel jamb/heater cover (#3).

8.Remove the threshold (#6) and peel the tape off the cover channel (#9) to the bottom of the threshold.

9.Tape the heater cable in the groove around the door jamb, and run the leads in to junction box.

10.Replace the stainless steel heater covers (#3) and the threshold plate (#6). Install all screws securely.

11.Connect the electricity and turn on the circuit breaker.

12.Allow 15 minutes for the heater to warm up, feel to see if it has warmed the threshold (#6) and the heater covers (#3).

Description Of Numbered Parts in Figure #19 and #20

1.Heater Cable

2.Fiberglass reinforced plastic

3.Magnetic stainless steel heater cover

4.Interior/Exterior metal finish

5.Floor section (may not be on all walk-ins)

6.Stainless steel threshold plate

7.Stainless steel screws

8.4 inch Urethane insulation

9.Channel cover

10.Stainless steel screws

Figure #19

Figure #20

19

Image 21
Contents For All W. A. Brown & Son, Inc. Models Table of Contents Terminology Receiving and UncratingInstallation of floor panels Floor Preparation and InstallationDiamond Aluminum Treadplate Overlay Instructions Layout of the FloorFloor Spline Layout and Installation Cam Lock InstallationFloorless Walk-In Layout Ramset Studs Or ScrewsFigure #4 PVC Panel Track Installation for Floorless Walk-InWall Protector Plate Wainscotting Instructions Wall Panel InstallationMultiple Compartment Walk-Ins With a Tee Panel Top Panel InstallationInstallation of Membrane Roof Cap For Outside Units Membrane Roof CapPenetrations of Panels Install to existing wall Duro-LastRoof Cap Installation for outside installationPainting Fiber Cement Fiber Cement Finish Panels InstallationWhen ceiling is not Top Panel Trim Installation Installation of 1/2 x 5 Trim on Top PanelsDrop-Off Walk-In Coolers and Freezers Installing the Refrigeration System EZ Pack Installation InstructionsSetting Controls Final Checks Before OperationWiring the Door Heater, Lights & Windows Roof Cap & Curb Installation Figure #14Vapor Proof Light Fluorescent LightsHousekeeping and Safety Recommendations Housekeeping and SafetyCleaning of Stucco Aluminum & Galvalume Plus Cleaning Stainless Steel FinishesHow To Call for Service Repair Replacement PartsSize Lifetime Limited Cabinet Warranty Instructions for removing Door Leaf with Spring Adjusting Door Closer See Figure #17Loaded Hinges See Figure #15 See sketchDescription Of Numbered Door Section Components Replacement KeysDescription Of Numbered Parts in Figure #19 and #20 Guidelines For Replacing Door Heater CableRelacing Door Gasket Cross Section Of Door LeafDescription Of Numbered Parts in Figure #21 Replacing Flush Dial Thermometer Installing Surface Dial Thermometer Figure #23Replacing a Pressure Relief Port Replacing The Digital ThermometerDescription Of Numbered Parts, Figure #24 and #25 Description Of Numbered Parts, Figure #27, and #28Figure #26 Electrical Hook-Up to Junction BoxFigure #30 Malfunction Possible Cause Solution Refrigeration Trouble Shooting GuideInput Voltage