Vanguard Heating SDVBP(A) High Altitude Installation, Parts Lists for Venting Kits and Components

Page 17

OWNER’S MANUAL

VENTING INSTALLATION

Continued

Note: Install restrictor into 4" collar of burner system as shown.

RVKBK Kit Shown

Vertical Venting

V = 40' max.

Figure 37 - Vertical Rigid Venting Configuration With No Horizontal Run

HIGH ALTITUDE

INSTALLATION

Your Vanguard cast iron stove and direct- vent burner system has been AGA tested and approved for elevations from 0-2000 feet and CGA certified for elevations from 0-4500 feet.

When installing this stove at an elevation above 2000 feet (in the USA), you may need to decrease the input rating by changing the existing burner orifice to a smaller size. Re- duce input 4% for each 1000 feet above sea level. Check with your local gas company for proper orifice size identification.

When installing this stove at an elevation above 4500 feet (in Canada), check with local authorities.

Consult your local gas company to help de- termine the proper orifice for your location.

For assistance with any high altitude instal- lation contact DESA International’s Tech- nical Service Department at 1-800-DESA- LOG (1-800-337-2564).

PARTS LISTS FOR VENTING KITS AND COMPONENTS

Vanguard Rigid Venting

Number Description

GFVKBK Ground Floor Rigid Vent Kit Includes: 7" x 60° Elbow, Ex- tended 7" Adjustable Pipe (7-12"), Horizontal Termination, Wall Thimble and 14 Screws

BVKBK

Basement Rigid Vent Kit

 

Includes: 7" x 30° Elbow, 7" x 4'

 

Pipe, 7" x 90° Elbow, 7" Adjust-

 

able Pipe (7-12"), Wall Thimble,

 

Horizontal Termination, RTV Sili-

 

cone and 20 Screws

SVKBK

Snorkel Rigid Vent Kit

 

Includes: 7" x 30° Elbow, 7" x 4'

 

Pipe, 7" x 90° Elbow, 7" Adjust-

 

able Pipe (7-12"), Wall Thimble,

 

36" Snorkel Termination, RTV

 

Silicone and 28 Screws

RVKBK

Roof Rigid Vent Kit

 

Includes: Flue Restrictor, Storm

 

Collar, 7" x 30° Elbow, 7" x 4'

 

Pipe, 7" x 2' Pipe, 7" Adjustable

 

Pipe (7-12"), Firestop Support,

 

Roof Flashing, RTV Silicone, Ver-

 

tical Termination, and 26 screws

D1000BK 7" x 12" Black Coaxial Pipe (1 pk)

D1010BK 7" x 24" Black Coaxial Pipe (1 pk)

D1020BK 7" x 48" Black Coaxial Pipe (1 pk)

D1030BK 7" Adjustable (7-12") Black

Coaxial Pipe (1 pk)

D1050BK 7" x 6" Black Coaxial Pipe (1 pk) D2000BK 7" X 90° Elbow (1 pk) D2010BK 7" x 45° Elbow (1 pk) D2020BK 7" x 30° Elbow

D2030BK 7" x 60° Elbow

Vanguard Rigid Venting (Cont.)

Number Description

D3000 Wall Strap/Offset Support (6 pcs.)

D3010 Storm Collar (6 pcs.)

D3040 Vertical Termination Cap (1 pk)

D3020 Wall Thimble (6 pcs.)

D3050 Vertical Restrictor (6 pcs.)

D3060 Ceiling Firestop/Support (6 pcs.)

D3070 Rectangular Horizontal Rigid Vent Termination Cap

D3090 Cathedral Ceiling Support Box

D4000 Roof Flashing 6/12-9/12

D4010 Roof Flashing 9/12-12/12

D5000 Wood/Vinyl Siding Standoff (6 pcs.)

SIMPSON DURA-VENT GS 4" x 6 5/8 " (Black Pipe)

Number Description

Available from DESA International:

SD2040B Simpson Dura-Vent GS 30° Elbow (6 pcs.)

SD2050B Simpson Dura-Vent GS 60° Elbow (6 pcs.)

AvailablefromSimpsonDura-Ventonly:

902B 7" x 48" Pipe

903B 7" x 36" Pipe

904B 7" x 24" Pipe

906B 7" x 12" Pipe

907B 7" x 9" Pipe

908B 7" x 6" Pipe

911B 7" Adjustable (11"-14 5/8") Pipe

940Wall Thimble

941Cathedral Ceiling Support Box

943Roof Flashing 0/12-6/12

943S Roof Flashing 7/12-12/12

945B 7" x 45° Elbow

950Vinyl Siding Standoff

953Storm Collar

963Ceiling Firestop

98136" Snorkel Termination

984Horizontal Termination Vent Cap

988Wall Strap

990B 7" x 90° Elbow

991Vertical High Wind Termination

105499

17

Image 17
Contents For Your Safety What to do if YOU Smell GAS For Your SafetySdvbna and Sdvbpa Cast Iron Stove and Burner System Safety InformationProduct Identification Product FeaturesLocal Codes Glossary TermsLocation and Space Requirements PRE-INSTALLATION PreparationLift off corrugated box enclosing stove body crating Stove Body AssemblyInstalling DIRECT-VENT Burner System Into Stove Body Cast Iron Stove and DIRECT-VENT Burner System AssemblyInstalling GA3700/DA3610T Blowers Installing Optional Blower AccessoryLocation of Vent Termination Installing Rear CoverGeneral Venting General Venting Installation Precautions Venting InstallationInstallation Planning Installing Vent System in a ChaseSnorkel Termination Installation for Horizontal TerminationVent Pipe Connections Horizontal Venting Horizontal Termination Configurations Flat Ceiling Installation Installation for Vertical TerminationIf area above is a room, install firestop above framed hole Cathedral Ceiling InstallationVertical Rigid Venting Configuration Using One 90 Elbow Vertical Termination ConfigurationsVanguard Rigid Venting High Altitude InstallationParts Lists for Venting Kits and Components Installing GAS Piping to STOVE/BURNER System Location Stove DIRECT-VENT Burner System InstallationInstallation Items Needed Check GAS TypeChecking GAS Connections Connecting Stove Burner System to GAS SupplyPressure Testing Gas Supply Piping System System Gas Connections Pressure Testing BurnerInstalling Optional Wall Mounted Thermostat GWMT1 Installing Optional Wall Mount Switch GWMS2Receiver Terminal Wires Battery Clip Volt Battery Installing Remote ReceiverInstalling Log No Installing LOGS, Lava Rock and Glowing EmbersManual Lighting Procedure For Your Safety Read Before LightingOperating Stove with Burner System Lighting InstructionsThermostat Control Operation Optional Remote OperationGhrc Series Operation Ghrct Series OperationPilot Assembly Operating Optional Blower AccessoryInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatGlass Door Cleaning and MaintenancePilot and Burners LogsObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement Technical Service Replacement PartsWiring Diagram Service HintsSdvbna Sdvbpa SpecificationsAccessories Sdvbna Sdvbpa Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListIndicates Color Suffix Designation Amity SCIVF* Series PSCIVF* SeriesKEY Part Description QTY Warranty Information