Vanguard Heating SDVBP(A) High Altitude Installation, Parts Lists for Venting Kits and Components

Page 17

OWNER’S MANUAL

VENTING INSTALLATION

Continued

Note: Install restrictor into 4" collar of burner system as shown.

RVKBK Kit Shown

Vertical Venting

V = 40' max.

Figure 37 - Vertical Rigid Venting Configuration With No Horizontal Run

HIGH ALTITUDE

INSTALLATION

Your Vanguard cast iron stove and direct- vent burner system has been AGA tested and approved for elevations from 0-2000 feet and CGA certified for elevations from 0-4500 feet.

When installing this stove at an elevation above 2000 feet (in the USA), you may need to decrease the input rating by changing the existing burner orifice to a smaller size. Re- duce input 4% for each 1000 feet above sea level. Check with your local gas company for proper orifice size identification.

When installing this stove at an elevation above 4500 feet (in Canada), check with local authorities.

Consult your local gas company to help de- termine the proper orifice for your location.

For assistance with any high altitude instal- lation contact DESA International’s Tech- nical Service Department at 1-800-DESA- LOG (1-800-337-2564).

PARTS LISTS FOR VENTING KITS AND COMPONENTS

Vanguard Rigid Venting

Number Description

GFVKBK Ground Floor Rigid Vent Kit Includes: 7" x 60° Elbow, Ex- tended 7" Adjustable Pipe (7-12"), Horizontal Termination, Wall Thimble and 14 Screws

BVKBK

Basement Rigid Vent Kit

 

Includes: 7" x 30° Elbow, 7" x 4'

 

Pipe, 7" x 90° Elbow, 7" Adjust-

 

able Pipe (7-12"), Wall Thimble,

 

Horizontal Termination, RTV Sili-

 

cone and 20 Screws

SVKBK

Snorkel Rigid Vent Kit

 

Includes: 7" x 30° Elbow, 7" x 4'

 

Pipe, 7" x 90° Elbow, 7" Adjust-

 

able Pipe (7-12"), Wall Thimble,

 

36" Snorkel Termination, RTV

 

Silicone and 28 Screws

RVKBK

Roof Rigid Vent Kit

 

Includes: Flue Restrictor, Storm

 

Collar, 7" x 30° Elbow, 7" x 4'

 

Pipe, 7" x 2' Pipe, 7" Adjustable

 

Pipe (7-12"), Firestop Support,

 

Roof Flashing, RTV Silicone, Ver-

 

tical Termination, and 26 screws

D1000BK 7" x 12" Black Coaxial Pipe (1 pk)

D1010BK 7" x 24" Black Coaxial Pipe (1 pk)

D1020BK 7" x 48" Black Coaxial Pipe (1 pk)

D1030BK 7" Adjustable (7-12") Black

Coaxial Pipe (1 pk)

D1050BK 7" x 6" Black Coaxial Pipe (1 pk) D2000BK 7" X 90° Elbow (1 pk) D2010BK 7" x 45° Elbow (1 pk) D2020BK 7" x 30° Elbow

D2030BK 7" x 60° Elbow

Vanguard Rigid Venting (Cont.)

Number Description

D3000 Wall Strap/Offset Support (6 pcs.)

D3010 Storm Collar (6 pcs.)

D3040 Vertical Termination Cap (1 pk)

D3020 Wall Thimble (6 pcs.)

D3050 Vertical Restrictor (6 pcs.)

D3060 Ceiling Firestop/Support (6 pcs.)

D3070 Rectangular Horizontal Rigid Vent Termination Cap

D3090 Cathedral Ceiling Support Box

D4000 Roof Flashing 6/12-9/12

D4010 Roof Flashing 9/12-12/12

D5000 Wood/Vinyl Siding Standoff (6 pcs.)

SIMPSON DURA-VENT GS 4" x 6 5/8 " (Black Pipe)

Number Description

Available from DESA International:

SD2040B Simpson Dura-Vent GS 30° Elbow (6 pcs.)

SD2050B Simpson Dura-Vent GS 60° Elbow (6 pcs.)

AvailablefromSimpsonDura-Ventonly:

902B 7" x 48" Pipe

903B 7" x 36" Pipe

904B 7" x 24" Pipe

906B 7" x 12" Pipe

907B 7" x 9" Pipe

908B 7" x 6" Pipe

911B 7" Adjustable (11"-14 5/8") Pipe

940Wall Thimble

941Cathedral Ceiling Support Box

943Roof Flashing 0/12-6/12

943S Roof Flashing 7/12-12/12

945B 7" x 45° Elbow

950Vinyl Siding Standoff

953Storm Collar

963Ceiling Firestop

98136" Snorkel Termination

984Horizontal Termination Vent Cap

988Wall Strap

990B 7" x 90° Elbow

991Vertical High Wind Termination

105499

17

Image 17
Contents For Your Safety What to do if YOU Smell GAS For Your SafetySdvbna and Sdvbpa Cast Iron Stove and Burner System Safety InformationProduct Identification Product FeaturesLocal Codes Glossary TermsLocation and Space Requirements PRE-INSTALLATION PreparationLift off corrugated box enclosing stove body crating Stove Body AssemblyInstalling DIRECT-VENT Burner System Into Stove Body Cast Iron Stove and DIRECT-VENT Burner System AssemblyInstalling GA3700/DA3610T Blowers Installing Optional Blower AccessoryLocation of Vent Termination Installing Rear CoverGeneral Venting General Venting Installation Precautions Venting InstallationInstallation Planning Installing Vent System in a ChaseSnorkel Termination Installation for Horizontal TerminationVent Pipe Connections Horizontal Venting Horizontal Termination ConfigurationsFlat Ceiling Installation Installation for Vertical TerminationIf area above is a room, install firestop above framed hole Cathedral Ceiling InstallationVertical Rigid Venting Configuration Using One 90 Elbow Vertical Termination ConfigurationsVanguard Rigid Venting High Altitude InstallationParts Lists for Venting Kits and Components Installing GAS Piping to STOVE/BURNER System Location Stove DIRECT-VENT Burner System InstallationInstallation Items Needed Check GAS TypeChecking GAS Connections Connecting Stove Burner System to GAS SupplyPressure Testing Gas Supply Piping System System Gas Connections Pressure Testing BurnerInstalling Optional Wall Mounted Thermostat GWMT1 Installing Optional Wall Mount Switch GWMS2Receiver Terminal Wires Battery Clip Volt Battery Installing Remote ReceiverInstalling Log No Installing LOGS, Lava Rock and Glowing EmbersManual Lighting Procedure For Your Safety Read Before LightingOperating Stove with Burner System Lighting InstructionsThermostat Control Operation Optional Remote OperationGhrc Series Operation Ghrct Series OperationPilot Assembly Operating Optional Blower AccessoryInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatGlass Door Cleaning and MaintenancePilot and Burners LogsObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement Technical Service Replacement PartsWiring Diagram Service HintsSdvbna Sdvbpa SpecificationsAccessories Sdvbna Sdvbpa Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListIndicates Color Suffix Designation Amity SCIVF* Series PSCIVF* SeriesKEY Part Description QTY Warranty Information

SDVBP(A), SDVBN(A) specifications

Vanguard Heating SDVBN(A) and SDVBP(A) are innovative heating solutions designed for residential and commercial applications, aiming to deliver unparalleled efficiency and comfort. These models showcase advanced technologies tailored to meet modern heating demands while ensuring minimal environmental impact.

One of the standout features of the Vanguard Heating SDVBN(A) and SDVBP(A) is their highly efficient heating performance. Operating with an Annual Fuel Utilization Efficiency (AFUE) rating of up to 95%, these models convert a significant portion of fuel into heat, minimizing energy waste and lowering utility costs. This efficiency translates to substantial savings for homeowners and businesses alike, making them an economically sound choice in the long run.

The SDVBN(A) and SDVBP(A) are equipped with variable-speed blower motors, allowing for precise control of airflow. This technology not only enhances comfort by maintaining consistent temperature levels throughout spaces but also contributes to reduced noise levels during operation. The quiet performance of these units is particularly appealing for residential settings, such as bedrooms and living areas.

In terms of versatility, Vanguard offers multiple configurations, allowing installers to tailor the heating system to specific requirements. Whether it’s a large open plan or a more segmented layout, the adjustable airflow and zoned heating capabilities ensure that every corner of the space is adequately warmed.

Another notable characteristic is the integrated smart technology. Both models come with advanced control systems that can be easily connected to compatible smart thermostats. This allows users to monitor and adjust heating settings remotely, providing added convenience and optimizing energy usage according to individual schedules.

Moreover, the SDVBN(A) and SDVBP(A) feature robust construction designed for durability. With high-quality materials and components, these units can withstand the rigors of daily use, ensuring reliable performance throughout their lifespan. Regular maintenance is simplified due to accessible design, empowering users or service technicians to conduct routine checks and repairs with ease.

Vanguard Heating has also incorporated safety features, including built-in sensors that monitor system performance and automatically shut down the unit in case of any malfunctions. This proactive approach provides peace of mind, knowing that the heating system is both efficient and safe.

In summary, Vanguard Heating SDVBN(A) and SDVBP(A) models embody cutting-edge technology, efficiency, and reliability in home and commercial heating solutions. Their ability to deliver comfortable, quiet, and economical heating while prioritizing safety and ease of maintenance makes them an excellent choice for any heating application.