Vanguard Heating SDVBP(A) Product Identification, Local Codes, Product Features, Glossary Terms

Page 3

OWNER’S MANUAL

PRODUCT

IDENTIFICATION

Cast Iron

Stove Body

Log Set

ON

LO HI

 

OFF

 

 

PI

AUTO

 

OFFL

 

O

 

 

T

 

 

ON

ON/OFF

Control Valve

Switch

 

Piezo Ignitor

LOCAL CODES

Install and use stove and burner system with care. Follow all local codes. In the absence to local codes, use the current National Fuel Gas Code ANS Z223.1, also known as NFPA 54* (USA) or the current CAN/CGA- B149[.1 or .2] Installation Codes (Canada).

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

PRODUCT

FEATURES

OPERATION

This cast iron stove with burner system is clean burning and vents easily through out- side walls or vertically using outside air for combustion. Heat is generated by both real- istic flames and glowing embers. When used without the blower accessory, the stove with burner system requires no electricity making it ideal for emergency backup heat.

Vent

Opening

Rear Cover

Pilot Assy

Blower with Adjustment (Optional Installation)

Glowing Embers

Cast Iron

Stove Body

Burner

Glass Door

Assy

Lava Rock

Lava Rock

Plate

Grate Assembly

PIEZO IGNITOR

This burner system has a piezo ignitor. This system requires no matches, batteries, or other sources to light burner system.

GLOSSARY OF

TERMS

Chase - A box-like enclosure to protect venting from the elements when the venting run is on the outside of a structure.

Mastic - A pliable sealent for use around the vent terminal.

Snorkel Termination - A box that raises the horizontal termination above ground level clearances.

Vent Terminal - Mounted on an outside wall or roof to separate the inlet and outlet of the vent system and protect it from weather.

Vinyl Siding Standoff - A metal box that separates the vent cap from vinyl siding.

Figure 1 - Vanguard Direct-Vent Burner System Shown Installed in Approved Vanguard Cast Iron Stove Body Models SCIVF Series and PSCIVF Series Only

Wall Thimble/Firestop - A metal plate used to secure the vent pipe when it passes through a wall or ceiling.

105499

3

Image 3
Contents For Your Safety What to do if YOU Smell GAS For Your SafetySdvbna and Sdvbpa Cast Iron Stove and Burner System Safety InformationGlossary Terms Product FeaturesProduct Identification Local CodesLocation and Space Requirements PRE-INSTALLATION PreparationLift off corrugated box enclosing stove body crating Stove Body AssemblyInstalling DIRECT-VENT Burner System Into Stove Body Cast Iron Stove and DIRECT-VENT Burner System AssemblyInstalling GA3700/DA3610T Blowers Installing Optional Blower AccessoryInstalling Rear Cover General VentingLocation of Vent Termination General Venting Installing Vent System in a Chase Venting InstallationInstallation Precautions Installation PlanningSnorkel Termination Installation for Horizontal TerminationVent Pipe Connections Horizontal Venting Horizontal Termination ConfigurationsFlat Ceiling Installation Installation for Vertical TerminationIf area above is a room, install firestop above framed hole Cathedral Ceiling InstallationVertical Rigid Venting Configuration Using One 90 Elbow Vertical Termination ConfigurationsHigh Altitude Installation Parts Lists for Venting Kits and ComponentsVanguard Rigid Venting Check GAS Type Stove DIRECT-VENT Burner System InstallationInstalling GAS Piping to STOVE/BURNER System Location Installation Items NeededConnecting Stove Burner System to GAS Supply Pressure Testing Gas Supply Piping SystemChecking GAS Connections System Gas Connections Pressure Testing BurnerInstalling Optional Wall Mounted Thermostat GWMT1 Installing Optional Wall Mount Switch GWMS2Receiver Terminal Wires Battery Clip Volt Battery Installing Remote ReceiverInstalling Log No Installing LOGS, Lava Rock and Glowing EmbersLighting Instructions For Your Safety Read Before LightingManual Lighting Procedure Operating Stove with Burner SystemGhrct Series Operation Optional Remote OperationThermostat Control Operation Ghrc Series OperationOperating Optional GWMT1 Wall Mounted Thermostat Operating Optional Blower AccessoryPilot Assembly Inspecting BurnersLogs Cleaning and MaintenanceGlass Door Pilot and BurnersObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement Service Hints Replacement PartsTechnical Service Wiring DiagramSdvbna Sdvbpa SpecificationsAccessories Sdvbna Sdvbpa Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListIndicates Color Suffix Designation Amity SCIVF* Series PSCIVF* SeriesKEY Part Description QTY Warranty Information

SDVBP(A), SDVBN(A) specifications

Vanguard Heating SDVBN(A) and SDVBP(A) are innovative heating solutions designed for residential and commercial applications, aiming to deliver unparalleled efficiency and comfort. These models showcase advanced technologies tailored to meet modern heating demands while ensuring minimal environmental impact.

One of the standout features of the Vanguard Heating SDVBN(A) and SDVBP(A) is their highly efficient heating performance. Operating with an Annual Fuel Utilization Efficiency (AFUE) rating of up to 95%, these models convert a significant portion of fuel into heat, minimizing energy waste and lowering utility costs. This efficiency translates to substantial savings for homeowners and businesses alike, making them an economically sound choice in the long run.

The SDVBN(A) and SDVBP(A) are equipped with variable-speed blower motors, allowing for precise control of airflow. This technology not only enhances comfort by maintaining consistent temperature levels throughout spaces but also contributes to reduced noise levels during operation. The quiet performance of these units is particularly appealing for residential settings, such as bedrooms and living areas.

In terms of versatility, Vanguard offers multiple configurations, allowing installers to tailor the heating system to specific requirements. Whether it’s a large open plan or a more segmented layout, the adjustable airflow and zoned heating capabilities ensure that every corner of the space is adequately warmed.

Another notable characteristic is the integrated smart technology. Both models come with advanced control systems that can be easily connected to compatible smart thermostats. This allows users to monitor and adjust heating settings remotely, providing added convenience and optimizing energy usage according to individual schedules.

Moreover, the SDVBN(A) and SDVBP(A) feature robust construction designed for durability. With high-quality materials and components, these units can withstand the rigors of daily use, ensuring reliable performance throughout their lifespan. Regular maintenance is simplified due to accessible design, empowering users or service technicians to conduct routine checks and repairs with ease.

Vanguard Heating has also incorporated safety features, including built-in sensors that monitor system performance and automatically shut down the unit in case of any malfunctions. This proactive approach provides peace of mind, knowing that the heating system is both efficient and safe.

In summary, Vanguard Heating SDVBN(A) and SDVBP(A) models embody cutting-edge technology, efficiency, and reliability in home and commercial heating solutions. Their ability to deliver comfortable, quiet, and economical heating while prioritizing safety and ease of maintenance makes them an excellent choice for any heating application.