Vanguard Heating SDVBN(A) Inspecting Burners, Operating Optional Blower Accessory, Pilot Assembly

Page 26

® SDVBN(A) AND SDVBP(A)

CAST IRON STOVE AND BURNER SYSTEM

OPERATING STOVE WITH BURNER SYSTEM

Continued

OPERATING

OPTIONAL BLOWER

ACCESSORY

Locate the blower controls by opening the lower door on the stove. Blower controls are located on the left side of the switch bracket to the left just inside the door.

Both the GA3700 manual blower and the DA3610T thermostatically-controlled blower have an ON setting and an OFF setting. The blower will only run when the switch is in the ON position. In the OFF position, the blower will not operate.

Note for DA3610T Only: If you are using DA3610T blower with optional thermo- stat (wall mount or remote control) for the burner system, your burner system and blower will not turn on and off at the same time. The burner system may run for sev- eral minutes before the blower turns on. After the burner system modulates to the pilot position, the blower will continue to run. The blower will shut off after the burner system temperature decreases.

The blower helps distribute heated air from the burner system. Periodically check the air passageways of the burner system and remove any dust, dirt, or other ob- structions that will hinder the flow of air.

OPERATING

OPTIONAL GWMT1

WALL MOUNTED

THERMOSTAT

WARNING: Do not connect the thermostat to a power source. Electrical shock and/or a fire haz- ard will occur.

Light the burner system as instructed in Lighting Instructions on page 24. Set wall thermostat to desired temperature.

Upon installation, the thermostat must be allowed to stabilize at room tempera- ture for a minimum of 30 minutes for proper operation.

To turn the burner system off, adjust thermostat to the lowest setting and turn the gas control knob back to PILOT. The pilot will remain lit.

IMPORTANT: To turn the pilot off, turn the gas control knob on the burner sys- tem to the OFF position.

INSPECTING

BURNERS

Check pilot flame pattern and burner flame patterns often.

PILOT ASSEMBLY

The pilot assembly is factory preset for the proper flame height. Alterations may have occurred during shipping and handling. Call a qualified service person to readjust the pilot if necessary.

The height of the thermopile must be 3/8" to 1/2" above the pilot flame as shown in Figure

61.The thermocouple must be at a height of about 1/8" above the pilot flame. The flame from the pilot burner must extend beyond both the thermocouple and thermopile.

If your pilot assembly does not meet these requirements:

turn burner system off (see To Turn Off Gas to Appliance, page 24)

seeTroubleshooting, pages 28 through 30

Thermopile

3/8" to 1/2"

Pilot Burner

1/8"

Thermocouple

Piezo Ignitor

BURNER FLAME PATTERN

Burner flames will be steady; not lifting or floating. Flame patterns will be different from unit to unit and will vary depending on installation type and weather conditions.

If the vent configuration is installed incor- rectly, the flames will lift or "ghost". This can be dangerous. Inspect the flames after installation to ensure proper installation and performance.

Figure 62 shows a typical flame pattern. If burnerflamepatterndiffersfromthatdescribed:

turn burner system off (see To Turn Off Gas to Appliance, page 24)

seeTroubleshooting, pages 28 through 30

Figure 62 - Typical Flame Pattern

This thermostat has been electronically calibrated at the factory and requires no adjustment or leveling.

Figure 61 - Pilot Assembly

26

105499

Image 26
Contents For Your Safety For Your Safety What to do if YOU Smell GASSafety Information Sdvbna and Sdvbpa Cast Iron Stove and Burner SystemLocal Codes Product FeaturesProduct Identification Glossary TermsPRE-INSTALLATION Preparation Location and Space RequirementsStove Body Assembly Lift off corrugated box enclosing stove body cratingCast Iron Stove and DIRECT-VENT Burner System Assembly Installing DIRECT-VENT Burner System Into Stove BodyInstalling Optional Blower Accessory Installing GA3700/DA3610T BlowersLocation of Vent Termination Installing Rear CoverGeneral Venting General Venting Installation Planning Venting InstallationInstallation Precautions Installing Vent System in a ChaseInstallation for Horizontal Termination Snorkel TerminationVent Pipe Connections Horizontal Termination Configurations Horizontal VentingInstallation for Vertical Termination Flat Ceiling InstallationCathedral Ceiling Installation If area above is a room, install firestop above framed holeVertical Termination Configurations Vertical Rigid Venting Configuration Using One 90 ElbowVanguard Rigid Venting High Altitude InstallationParts Lists for Venting Kits and Components Installation Items Needed Stove DIRECT-VENT Burner System InstallationInstalling GAS Piping to STOVE/BURNER System Location Check GAS TypeChecking GAS Connections Connecting Stove Burner System to GAS SupplyPressure Testing Gas Supply Piping System Pressure Testing Burner System Gas ConnectionsInstalling Optional Wall Mount Switch GWMS2 Installing Optional Wall Mounted Thermostat GWMT1Installing Remote Receiver Receiver Terminal Wires Battery Clip Volt BatteryInstalling LOGS, Lava Rock and Glowing Embers Installing Log NoOperating Stove with Burner System For Your Safety Read Before LightingManual Lighting Procedure Lighting InstructionsGhrc Series Operation Optional Remote OperationThermostat Control Operation Ghrct Series OperationInspecting Burners Operating Optional Blower AccessoryPilot Assembly Operating Optional GWMT1 Wall Mounted ThermostatPilot and Burners Cleaning and MaintenanceGlass Door LogsTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement Wiring Diagram Replacement PartsTechnical Service Service HintsSpecifications Sdvbna SdvbpaAccessories Illustrated Parts Breakdown Sdvbna SdvbpaParts List KEY Part Number Description QTYAmity SCIVF* Series PSCIVF* Series Indicates Color Suffix DesignationKEY Part Description QTY Warranty Information

SDVBP(A), SDVBN(A) specifications

Vanguard Heating SDVBN(A) and SDVBP(A) are innovative heating solutions designed for residential and commercial applications, aiming to deliver unparalleled efficiency and comfort. These models showcase advanced technologies tailored to meet modern heating demands while ensuring minimal environmental impact.

One of the standout features of the Vanguard Heating SDVBN(A) and SDVBP(A) is their highly efficient heating performance. Operating with an Annual Fuel Utilization Efficiency (AFUE) rating of up to 95%, these models convert a significant portion of fuel into heat, minimizing energy waste and lowering utility costs. This efficiency translates to substantial savings for homeowners and businesses alike, making them an economically sound choice in the long run.

The SDVBN(A) and SDVBP(A) are equipped with variable-speed blower motors, allowing for precise control of airflow. This technology not only enhances comfort by maintaining consistent temperature levels throughout spaces but also contributes to reduced noise levels during operation. The quiet performance of these units is particularly appealing for residential settings, such as bedrooms and living areas.

In terms of versatility, Vanguard offers multiple configurations, allowing installers to tailor the heating system to specific requirements. Whether it’s a large open plan or a more segmented layout, the adjustable airflow and zoned heating capabilities ensure that every corner of the space is adequately warmed.

Another notable characteristic is the integrated smart technology. Both models come with advanced control systems that can be easily connected to compatible smart thermostats. This allows users to monitor and adjust heating settings remotely, providing added convenience and optimizing energy usage according to individual schedules.

Moreover, the SDVBN(A) and SDVBP(A) feature robust construction designed for durability. With high-quality materials and components, these units can withstand the rigors of daily use, ensuring reliable performance throughout their lifespan. Regular maintenance is simplified due to accessible design, empowering users or service technicians to conduct routine checks and repairs with ease.

Vanguard Heating has also incorporated safety features, including built-in sensors that monitor system performance and automatically shut down the unit in case of any malfunctions. This proactive approach provides peace of mind, knowing that the heating system is both efficient and safe.

In summary, Vanguard Heating SDVBN(A) and SDVBP(A) models embody cutting-edge technology, efficiency, and reliability in home and commercial heating solutions. Their ability to deliver comfortable, quiet, and economical heating while prioritizing safety and ease of maintenance makes them an excellent choice for any heating application.