RECEIVER AND HAND-HELD REMOTE CONTROL KIT GHRC

For all models. Allows the burner system to be turned on and off conveniently.

WALL MOUNTED THERMOSTAT CONTROL KIT GWMT1 (Not Shown)

Allows easy wall access to the operation of your burner system. This will allow you thermostatic control with the convenience of a wall switch.

WALL MOUNTED ON/OFF SWITCH - GWMS2

(Not Shown)

Allows burner system to be turned on and off with a wall switch.

MANUAL BLOWER KIT GA3700

Manual-variable control blower accessory for both the SDVBN(A) and SDVBP(A) Series burner systems.

THERMOSTATICALLY- CONTROLLED BLOWER KIT DA3610T

Provides better heat distribution. Blower turns off and on automatically, as needed. Complete installation and operation instruc- tions included in this manual.

 

HI

MAN

TEMP

AUTO

LO

ON

 

 

OFF

STATUS

 

RECEIVER AND HAND-HELD THERMOSTAT REMOTE CONTROL KIT - GHRCT

Allows the burner system to be operated in a manually or thermostatically-controlled mode. You can adjust your heat settings and turn the burner system on or off without leaving the comfort of your easy chair. (Re- quires part no. 103284-04 wire harness in- cluded with burner system.)

105499

33

Image 33
Contents For Your Safety What to do if YOU Smell GAS For Your SafetySdvbna and Sdvbpa Cast Iron Stove and Burner System Safety InformationProduct Identification Product FeaturesLocal Codes Glossary TermsLocation and Space Requirements PRE-INSTALLATION PreparationLift off corrugated box enclosing stove body crating Stove Body AssemblyInstalling DIRECT-VENT Burner System Into Stove Body Cast Iron Stove and DIRECT-VENT Burner System AssemblyInstalling GA3700/DA3610T Blowers Installing Optional Blower AccessoryInstalling Rear Cover General VentingLocation of Vent Termination General Venting Installation Precautions Venting InstallationInstallation Planning Installing Vent System in a ChaseSnorkel Termination Installation for Horizontal TerminationVent Pipe Connections Horizontal Venting Horizontal Termination ConfigurationsFlat Ceiling Installation Installation for Vertical TerminationIf area above is a room, install firestop above framed hole Cathedral Ceiling InstallationVertical Rigid Venting Configuration Using One 90 Elbow Vertical Termination ConfigurationsHigh Altitude Installation Parts Lists for Venting Kits and ComponentsVanguard Rigid Venting Installing GAS Piping to STOVE/BURNER System Location Stove DIRECT-VENT Burner System InstallationInstallation Items Needed Check GAS TypeConnecting Stove Burner System to GAS Supply Pressure Testing Gas Supply Piping SystemChecking GAS Connections System Gas Connections Pressure Testing BurnerInstalling Optional Wall Mounted Thermostat GWMT1 Installing Optional Wall Mount Switch GWMS2Receiver Terminal Wires Battery Clip Volt Battery Installing Remote ReceiverInstalling Log No Installing LOGS, Lava Rock and Glowing EmbersManual Lighting Procedure For Your Safety Read Before LightingOperating Stove with Burner System Lighting InstructionsThermostat Control Operation Optional Remote OperationGhrc Series Operation Ghrct Series OperationPilot Assembly Operating Optional Blower AccessoryInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatGlass Door Cleaning and MaintenancePilot and Burners LogsObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement Technical Service Replacement PartsWiring Diagram Service HintsSdvbna Sdvbpa SpecificationsAccessories Sdvbna Sdvbpa Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListIndicates Color Suffix Designation Amity SCIVF* Series PSCIVF* SeriesKEY Part Description QTY Warranty Information

SDVBP(A), SDVBN(A) specifications

Vanguard Heating SDVBN(A) and SDVBP(A) are innovative heating solutions designed for residential and commercial applications, aiming to deliver unparalleled efficiency and comfort. These models showcase advanced technologies tailored to meet modern heating demands while ensuring minimal environmental impact.

One of the standout features of the Vanguard Heating SDVBN(A) and SDVBP(A) is their highly efficient heating performance. Operating with an Annual Fuel Utilization Efficiency (AFUE) rating of up to 95%, these models convert a significant portion of fuel into heat, minimizing energy waste and lowering utility costs. This efficiency translates to substantial savings for homeowners and businesses alike, making them an economically sound choice in the long run.

The SDVBN(A) and SDVBP(A) are equipped with variable-speed blower motors, allowing for precise control of airflow. This technology not only enhances comfort by maintaining consistent temperature levels throughout spaces but also contributes to reduced noise levels during operation. The quiet performance of these units is particularly appealing for residential settings, such as bedrooms and living areas.

In terms of versatility, Vanguard offers multiple configurations, allowing installers to tailor the heating system to specific requirements. Whether it’s a large open plan or a more segmented layout, the adjustable airflow and zoned heating capabilities ensure that every corner of the space is adequately warmed.

Another notable characteristic is the integrated smart technology. Both models come with advanced control systems that can be easily connected to compatible smart thermostats. This allows users to monitor and adjust heating settings remotely, providing added convenience and optimizing energy usage according to individual schedules.

Moreover, the SDVBN(A) and SDVBP(A) feature robust construction designed for durability. With high-quality materials and components, these units can withstand the rigors of daily use, ensuring reliable performance throughout their lifespan. Regular maintenance is simplified due to accessible design, empowering users or service technicians to conduct routine checks and repairs with ease.

Vanguard Heating has also incorporated safety features, including built-in sensors that monitor system performance and automatically shut down the unit in case of any malfunctions. This proactive approach provides peace of mind, knowing that the heating system is both efficient and safe.

In summary, Vanguard Heating SDVBN(A) and SDVBP(A) models embody cutting-edge technology, efficiency, and reliability in home and commercial heating solutions. Their ability to deliver comfortable, quiet, and economical heating while prioritizing safety and ease of maintenance makes them an excellent choice for any heating application.