Vanguard Heating SDVBN(A), SDVBP(A) Stove DIRECT-VENT Burner System Installation, Check GAS Type

Page 18

® SDVBN(A) AND SDVBP(A)

CAST IRON STOVE AND BURNER SYSTEM

STOVE AND

DIRECT-VENT BURNER SYSTEM INSTALLATION

CHECK GAS TYPE

Use proper gas type for the burner system unit you are installing. If you have conflict- ing gas types, do not install burner system. See dealer where you purchased the stove and burner system for proper burner system according to your gas type.

INSTALLING GAS PIPING TO STOVE/BURNER SYSTEM LOCATION

WARNING: A qualified ser- vice person must connect burner system to gas supply. Follow all local codes.

CAUTION: For propane/LP units, never connect burner sys- tem directly to the propane/LP supply. This burner system re- quires an external regulator (not supplied). Install the external regu- lator between the burner system and propane/LP supply.

Installation Items Needed

Before installing stove and burner system, make sure you have the items listed below.

• external regulator (supplied by installer)

• piping (check local codes)

• sealant (resistant to propane/LP gas)

• manual shutoff valve *

• test gauge connection *

sediment trap

tee joint

pipe wrench

• approved flexible gas line with gas con-

 

nector (if allowed by local codes) (not

 

provided)

For propane/LP connections only, the in- staller must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, burner system regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure

38.Pointing the vent down protects it from freezing rain or sleet.

CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to burner sys- tem. If pipe is too small, undue loss of pressure will occur.

Installation must include a manual shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from burner system (see Figure 39).

IMPORTANT: Install main gas valve (manual shutoff valve) in an accessible lo- cation. The main gas valve is for turning on and shutting off the gas to the appliance.

Check your building codes for any special requirements for locating manual shutoff valve to stoves.

A.G.A. Design-Certified Manual

Shutoff Valve with 1/8" NPT Tap*

Approved Flexible

Gas Line

3" Minimum

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged burner system valves.

CAUTION: Use pipe joint seal- ant that is resistant to liquid pe- troleum (LP) gas.

We recommend that you install a sediment trap/drip leg in supply line as shown in Figure 39. Locate sediment trap/drip leg where it is within reach for cleaning. Install in piping system between fuel supply and burner system. Locate sediment trap/drip leg where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into burner system gas controls. If sediment trap/drip leg is not installed or is installed wrong, burner system may not run properly.

Propane/LP

Supply Tank

External

Regulator

Vent

Pointing

Down

Figure 38 - External Regulator with Vent Pointing Down (Propane/LP Only)

Natural - From Gas

Meter (5" W.C. to 10.5"

W.C. Pressure )

Propane/LP - From External Regulator (11" W.C. to 14"

W.C. Pressure)

*An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Pur- chase the A.G.A. design-certified manual shutoff valve from your dealer.

Cap Pipe Nipple Tee Joint

Sediment Trap/Drip Leg

*The A.G.A. design-certified manual shutoff valve may be supplied with the appliance or you can purchase it from your dealer.

Figure 39 - Gas Connection

18

105499

Image 18
Contents For Your Safety For Your Safety What to do if YOU Smell GASSafety Information Sdvbna and Sdvbpa Cast Iron Stove and Burner SystemLocal Codes Product FeaturesProduct Identification Glossary TermsPRE-INSTALLATION Preparation Location and Space RequirementsStove Body Assembly Lift off corrugated box enclosing stove body cratingCast Iron Stove and DIRECT-VENT Burner System Assembly Installing DIRECT-VENT Burner System Into Stove BodyInstalling Optional Blower Accessory Installing GA3700/DA3610T BlowersInstalling Rear Cover General VentingLocation of Vent Termination General Venting Installation Planning Venting InstallationInstallation Precautions Installing Vent System in a ChaseInstallation for Horizontal Termination Snorkel TerminationVent Pipe Connections Horizontal Termination Configurations Horizontal VentingInstallation for Vertical Termination Flat Ceiling InstallationCathedral Ceiling Installation If area above is a room, install firestop above framed holeVertical Termination Configurations Vertical Rigid Venting Configuration Using One 90 ElbowHigh Altitude Installation Parts Lists for Venting Kits and ComponentsVanguard Rigid Venting Installation Items Needed Stove DIRECT-VENT Burner System InstallationInstalling GAS Piping to STOVE/BURNER System Location Check GAS TypeConnecting Stove Burner System to GAS Supply Pressure Testing Gas Supply Piping SystemChecking GAS Connections Pressure Testing Burner System Gas ConnectionsInstalling Optional Wall Mount Switch GWMS2 Installing Optional Wall Mounted Thermostat GWMT1Installing Remote Receiver Receiver Terminal Wires Battery Clip Volt BatteryInstalling LOGS, Lava Rock and Glowing Embers Installing Log NoOperating Stove with Burner System For Your Safety Read Before LightingManual Lighting Procedure Lighting InstructionsGhrc Series Operation Optional Remote OperationThermostat Control Operation Ghrct Series OperationInspecting Burners Operating Optional Blower AccessoryPilot Assembly Operating Optional GWMT1 Wall Mounted ThermostatPilot and Burners Cleaning and MaintenanceGlass Door LogsTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement Wiring Diagram Replacement PartsTechnical Service Service HintsSpecifications Sdvbna SdvbpaAccessories Illustrated Parts Breakdown Sdvbna SdvbpaParts List KEY Part Number Description QTYAmity SCIVF* Series PSCIVF* Series Indicates Color Suffix DesignationKEY Part Description QTY Warranty Information

SDVBP(A), SDVBN(A) specifications

Vanguard Heating SDVBN(A) and SDVBP(A) are innovative heating solutions designed for residential and commercial applications, aiming to deliver unparalleled efficiency and comfort. These models showcase advanced technologies tailored to meet modern heating demands while ensuring minimal environmental impact.

One of the standout features of the Vanguard Heating SDVBN(A) and SDVBP(A) is their highly efficient heating performance. Operating with an Annual Fuel Utilization Efficiency (AFUE) rating of up to 95%, these models convert a significant portion of fuel into heat, minimizing energy waste and lowering utility costs. This efficiency translates to substantial savings for homeowners and businesses alike, making them an economically sound choice in the long run.

The SDVBN(A) and SDVBP(A) are equipped with variable-speed blower motors, allowing for precise control of airflow. This technology not only enhances comfort by maintaining consistent temperature levels throughout spaces but also contributes to reduced noise levels during operation. The quiet performance of these units is particularly appealing for residential settings, such as bedrooms and living areas.

In terms of versatility, Vanguard offers multiple configurations, allowing installers to tailor the heating system to specific requirements. Whether it’s a large open plan or a more segmented layout, the adjustable airflow and zoned heating capabilities ensure that every corner of the space is adequately warmed.

Another notable characteristic is the integrated smart technology. Both models come with advanced control systems that can be easily connected to compatible smart thermostats. This allows users to monitor and adjust heating settings remotely, providing added convenience and optimizing energy usage according to individual schedules.

Moreover, the SDVBN(A) and SDVBP(A) feature robust construction designed for durability. With high-quality materials and components, these units can withstand the rigors of daily use, ensuring reliable performance throughout their lifespan. Regular maintenance is simplified due to accessible design, empowering users or service technicians to conduct routine checks and repairs with ease.

Vanguard Heating has also incorporated safety features, including built-in sensors that monitor system performance and automatically shut down the unit in case of any malfunctions. This proactive approach provides peace of mind, knowing that the heating system is both efficient and safe.

In summary, Vanguard Heating SDVBN(A) and SDVBP(A) models embody cutting-edge technology, efficiency, and reliability in home and commercial heating solutions. Their ability to deliver comfortable, quiet, and economical heating while prioritizing safety and ease of maintenance makes them an excellent choice for any heating application.