Vanguard Heating SDVBN(A), SDVBP(A) PRE-INSTALLATION Preparation, Location and Space Requirements

Page 4

® SDVBN(A) AND SDVBP(A)

CAST IRON STOVE AND BURNER SYSTEM

PRE-INSTALLATION PREPARATION

WARNING: A qualified ser- vice person must install stove and burner system. Follow all lo- cal codes.

CAUTION: This stove creates warm air currents. These currents move heat to wall surfaces next to stove. Installing stove next to vinyl or cloth wall coverings or operating stove where impurities (such as tobacco smoke, aro- matic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls.

LOCATION AND SPACE REQUIREMENTS

Determine the safest and most efficient loca- tion for your Vanguard cast iron stove. Make sure that rafters and wall studs are not in the way of the venting system. Choose a location where the heat output is not affected by drafts, air conditioning ducts, windows, or doors. Figure 2 shows some common loca- tions. Read all venting information in this manual. Be aware of all restrictions and pre- cautions before deciding the exact location for your stove.

When deciding the location of your stove, follow these rules:

On Wall with

Horizontal Termination

On Wall with Vertical Corner Installation Termination Through

Ceiling

Figure 2 - Common Stove Locations

Ceiling

42"

36"

 

 

 

 

 

4"

 

 

 

 

 

from

 

 

 

 

 

 

Front

 

 

 

 

 

 

 

 

 

 

Back

Wall

Floor

Must contain a minimum

of 1" clearance to combustibles

29"

1.Do not connect this stove and burner system to a chimney flue serving a separate solid-fuel burning fireplace or appliance.

2.Due to high temperatures, do not lo- cate this stove in high traffic areas or near furniture or draperies.

3.Proper clearances must be maintained, see Figure 3 and Figure 4 on page 5.

4.This stove is a freestanding unit de- signed to set directly on the floor. If your stove is to be installed directly on carpeting, vinyl tile, or any combustible material other than wood, it must be installed on a metal or wood panel ex- tending the full width and depth of the stove. See Figure 5, page 5.

4"

6"

Front

Figure 3 - Clearances for Standard Installation

4

105499

Image 4
Contents For Your Safety For Your Safety What to do if YOU Smell GASSafety Information Sdvbna and Sdvbpa Cast Iron Stove and Burner SystemProduct Features Product IdentificationLocal Codes Glossary TermsPRE-INSTALLATION Preparation Location and Space RequirementsStove Body Assembly Lift off corrugated box enclosing stove body cratingCast Iron Stove and DIRECT-VENT Burner System Assembly Installing DIRECT-VENT Burner System Into Stove BodyInstalling Optional Blower Accessory Installing GA3700/DA3610T BlowersGeneral Venting Installing Rear CoverLocation of Vent Termination General Venting Venting Installation Installation PrecautionsInstallation Planning Installing Vent System in a ChaseInstallation for Horizontal Termination Snorkel TerminationVent Pipe Connections Horizontal Termination Configurations Horizontal VentingInstallation for Vertical Termination Flat Ceiling InstallationCathedral Ceiling Installation If area above is a room, install firestop above framed holeVertical Termination Configurations Vertical Rigid Venting Configuration Using One 90 ElbowParts Lists for Venting Kits and Components High Altitude InstallationVanguard Rigid Venting Stove DIRECT-VENT Burner System Installation Installing GAS Piping to STOVE/BURNER System LocationInstallation Items Needed Check GAS TypePressure Testing Gas Supply Piping System Connecting Stove Burner System to GAS SupplyChecking GAS Connections Pressure Testing Burner System Gas ConnectionsInstalling Optional Wall Mount Switch GWMS2 Installing Optional Wall Mounted Thermostat GWMT1Installing Remote Receiver Receiver Terminal Wires Battery Clip Volt BatteryInstalling LOGS, Lava Rock and Glowing Embers Installing Log NoFor Your Safety Read Before Lighting Manual Lighting ProcedureOperating Stove with Burner System Lighting InstructionsOptional Remote Operation Thermostat Control OperationGhrc Series Operation Ghrct Series OperationOperating Optional Blower Accessory Pilot AssemblyInspecting Burners Operating Optional GWMT1 Wall Mounted ThermostatCleaning and Maintenance Glass DoorPilot and Burners LogsTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement Replacement Parts Technical ServiceWiring Diagram Service HintsSpecifications Sdvbna SdvbpaAccessories Illustrated Parts Breakdown Sdvbna SdvbpaParts List KEY Part Number Description QTYAmity SCIVF* Series PSCIVF* Series Indicates Color Suffix DesignationKEY Part Description QTY Warranty Information

SDVBP(A), SDVBN(A) specifications

Vanguard Heating SDVBN(A) and SDVBP(A) are innovative heating solutions designed for residential and commercial applications, aiming to deliver unparalleled efficiency and comfort. These models showcase advanced technologies tailored to meet modern heating demands while ensuring minimal environmental impact.

One of the standout features of the Vanguard Heating SDVBN(A) and SDVBP(A) is their highly efficient heating performance. Operating with an Annual Fuel Utilization Efficiency (AFUE) rating of up to 95%, these models convert a significant portion of fuel into heat, minimizing energy waste and lowering utility costs. This efficiency translates to substantial savings for homeowners and businesses alike, making them an economically sound choice in the long run.

The SDVBN(A) and SDVBP(A) are equipped with variable-speed blower motors, allowing for precise control of airflow. This technology not only enhances comfort by maintaining consistent temperature levels throughout spaces but also contributes to reduced noise levels during operation. The quiet performance of these units is particularly appealing for residential settings, such as bedrooms and living areas.

In terms of versatility, Vanguard offers multiple configurations, allowing installers to tailor the heating system to specific requirements. Whether it’s a large open plan or a more segmented layout, the adjustable airflow and zoned heating capabilities ensure that every corner of the space is adequately warmed.

Another notable characteristic is the integrated smart technology. Both models come with advanced control systems that can be easily connected to compatible smart thermostats. This allows users to monitor and adjust heating settings remotely, providing added convenience and optimizing energy usage according to individual schedules.

Moreover, the SDVBN(A) and SDVBP(A) feature robust construction designed for durability. With high-quality materials and components, these units can withstand the rigors of daily use, ensuring reliable performance throughout their lifespan. Regular maintenance is simplified due to accessible design, empowering users or service technicians to conduct routine checks and repairs with ease.

Vanguard Heating has also incorporated safety features, including built-in sensors that monitor system performance and automatically shut down the unit in case of any malfunctions. This proactive approach provides peace of mind, knowing that the heating system is both efficient and safe.

In summary, Vanguard Heating SDVBN(A) and SDVBP(A) models embody cutting-edge technology, efficiency, and reliability in home and commercial heating solutions. Their ability to deliver comfortable, quiet, and economical heating while prioritizing safety and ease of maintenance makes them an excellent choice for any heating application.