Kenmore 630.13959 manual Drain pump, Pump specifications, Solving installation issues, Cavitating

Page 15
Drain pump

COMPONENTS

Drain pump

Drain pumps are mounted to sumps in the front of dishwashers -- they’re easily accessible from the front of dishwashers by removing toe kicks.

Pump specifications

Drain pump is rated 120V, 60 Hz, 35W, 0.85A.

Solving installation issues

Often improper installations, not drain pump issues, cause dishwashers to not drain properly.

Must have drain hoses with high loops (min. 20” high) or drains with air gaps.

Drain hoses are 6’ long and can be up to 10’ long.

Secure drain hoses to rear of dishwashers with non-metal bands.

Make sure drain hoses aren’t kinked.

Cavitating

Cavitating may occur in any type of pump when impellers spin faster (from low inlet or outlet pressure), creating air pockets around impellers. Cavitating pumps can be noisy. Air gaps/high loops keep water contacting pump outlets, preventing air pockets from forming.

702_58300000149896_ara_en_b

Image 15
Contents Toronto, Ontario, Canada M5B 2C3 KENMORE ELITE DISHWASHERSSears Brands Management Corporation Hoffman Estates, IL 60179 U.S.ACOMPONENTS FAULT DIAGNOSTICSTECHNICAL SPECIFICATIONS WIRING DIAGRAMSIB. Electrical shock / fire hazards c h I. SAFETYSAFETY IA. General hazards mIIB. Alignment II. INSTALLATIONINSTALLATION IIA. Pre-InstallchecklistIIC. Electrical connection IIE. Drain and condensation hose connections INSTALLATION IID. Water connectionDry Assist Reset “Cancel – Reset”III. OPERATION Sanitized and Refill Rinse Agent lightsIIIC. Entering special programs and coding Changing basic featuresThe End of cycle tone volume can be changed End of cycle toneCX Control codes EX Error codesPX Program codes P4 = Control coding see CX control codesPreparing a dishwasher for showroom use Preparing a showroom dishwasher for resaleWARNING: Danger of electrical shock Adjusting rinse-aiddosage DispenserClosing dispenser doors Heater ratings IV.COMPONENTSTank Heater OperationDisk Water switchLeveling feet front and rear Microswitch CamCirculation pumps BLDCFloat Cavitating Pump specificationsSolving installation issues Drain pumpSiphoning Terminal connections Rast 5 connectorsJohnson Tee installations Washington State Water fill assemblyFlowmeter Using hinge slider sliding pulley Condensation tubeDoor spring Water inlet valve Hinge bushingTerminal box On/off switchDoor latch Terminal blockDrain hose Optical rinse-aidsensors Control module Display and power modulesAqua sensor Power moduleSump parts SumpBackflow check valve Info lights Spray arm feed tubeWater circulation OperationUnderstanding the 17-digitserial # Serial label warranty informationTo remove toe kick V. RepairTo remove outer door Tools needed: T20 Torx screwdriverTo flip dishwasher upside-down Tools needed: T20 Torx screwdriver and pliers To raise block up right side of tankConnection hints For access to circulation pumpTo remove water valve Tools needed: T20 Torx screwdriver & pliersTools needed: T-20Torx & flat blade screwdrivers To remove complete pumpTools needed: flat blade screwdriver Fascia panel mounted controls1.Remove outer door – see section VA To access base-mountedcontrolsBase mounted controls Tools needed: T-20Torx screwdriver & pliersFor access to heaters & NTC’s To remove heater, NTC & flow switchVE. Heaters 4.Push NTC latches and lift NTC from heater Softer bearing heatersVG. Drain pumps To remove dispensers1.Remove outer door --section VA Repair VF. 2-piecedrain hose connectionTo remove door latches 1.Remove fascia panel --section VDVI. Door latches Misaligned door latches VIA. Customer service test program VI.Fault DiagnosticsEntering customer service test program Fault DiagnosticsClearing error codes Error code displaysSymbol Viewing customer service programSteps to determine failure Dishwasher troubleshootingFault Failure ResolutionDispenser fill with Heater diagnosingWill not fill or does notControls timing out and showing “1” Heating system checklist if controls time outWhere to measure NTC resistances NTC resistance chartNot cleaning or locking sump filters Checklist if water leaks past doorsCosmetic / Customer Use / Installation Issues Water Leaking Past DoorsCustomer self-helpdiagnosing VII. Technical Specifications Technical SpecificationsUnsatisfactory washing results Wiring Diagrams VIII. Wiring Diagrams702_58300000149896_ara_en_b Wiring Diagrams