Kenmore 630.13953, 630.13959, 630.13952 manual Flowmeter

Page 17
Flowmeter

COMPONENTS

Time-fill water valves look like pressure-fill valves, but have tight part tolerances to insure consistent water levels. Time-fill valves can replace pressure-fill valves, but pressure-fill valves can’t replace time-fill valves.

Flowmeter

Dishwashers use a flowmeter to provide more accurate water filling. An impeller mounted magnet activates a reed switch.

Flowmeters are rated:

3.8 – 14 VDC, 1 ma

2.5 L / min, 0.5 – 10 bar

208 output pulses per liter

An arrow on the back of the flowmeter shows the water flow direction.

702_58300000149896_ara_en_b

Image 17
Contents Sears Brands Management Corporation KENMORE ELITE DISHWASHERSHoffman Estates, IL 60179 U.S.A Toronto, Ontario, Canada M5B 2C3TECHNICAL SPECIFICATIONS FAULT DIAGNOSTICSWIRING DIAGRAMS COMPONENTSSAFETY I. SAFETYIA. General hazards m IB. Electrical shock / fire hazards c hINSTALLATION II. INSTALLATIONIIA. Pre-Installchecklist IIB. AlignmentIIC. Electrical connection IIE. Drain and condensation hose connections INSTALLATION IID. Water connectionIII. OPERATION Reset “Cancel – Reset”Sanitized and Refill Rinse Agent lights Dry AssistThe End of cycle tone volume can be changed Changing basic featuresEnd of cycle tone IIIC. Entering special programs and codingPX Program codes EX Error codesP4 = Control coding see CX control codes CX Control codesWARNING: Danger of electrical shock Preparing a dishwasher for showroom usePreparing a showroom dishwasher for resale Closing dispenser doors Adjusting rinse-aiddosageDispenser Tank IV.COMPONENTSHeater Operation Heater ratingsLeveling feet front and rear Water switchMicroswitch Cam DiskFloat Circulation pumpsBLDC Solving installation issues Pump specificationsDrain pump CavitatingJohnson Tee installations Washington State Terminal connections Rast 5 connectorsWater fill assembly SiphoningFlowmeter Door spring Using hinge slider sliding pulleyCondensation tube Water inlet valve Hinge bushingDoor latch On/off switchTerminal block Terminal boxDrain hose Optical rinse-aidsensors Aqua sensor Display and power modulesPower module Control moduleBackflow check valve Sump partsSump Info lights Spray arm feed tubeWater circulation OperationUnderstanding the 17-digitserial # Serial label warranty informationTo remove outer door V. RepairTools needed: T20 Torx screwdriver To remove toe kickTo flip dishwasher upside-down Tools needed: T20 Torx screwdriver and pliers To raise block up right side of tankTo remove water valve For access to circulation pumpTools needed: T20 Torx screwdriver & pliers Connection hintsTools needed: flat blade screwdriver To remove complete pumpFascia panel mounted controls Tools needed: T-20Torx & flat blade screwdriversBase mounted controls To access base-mountedcontrolsTools needed: T-20Torx screwdriver & pliers 1.Remove outer door – see section VAVE. Heaters For access to heaters & NTC’sTo remove heater, NTC & flow switch 4.Push NTC latches and lift NTC from heater Softer bearing heaters1.Remove outer door --section VA To remove dispensersRepair VF. 2-piecedrain hose connection VG. Drain pumpsVI. Door latches To remove door latches1.Remove fascia panel --section VD Misaligned door latches Entering customer service test program VI.Fault DiagnosticsFault Diagnostics VIA. Customer service test programClearing error codes Error code displaysSymbol Viewing customer service programFault Dishwasher troubleshootingFailure Resolution Steps to determine failureDispenser Will not fill Heater diagnosingor does not fill withControls timing out and showing “1” Heating system checklist if controls time outWhere to measure NTC resistances NTC resistance chartCosmetic / Customer Use / Installation Issues Checklist if water leaks past doorsWater Leaking Past Doors Not cleaning or locking sump filtersCustomer self-helpdiagnosing Unsatisfactory washing results VII. Technical SpecificationsTechnical Specifications Wiring Diagrams VIII. Wiring Diagrams702_58300000149896_ara_en_b Wiring Diagrams