Kenmore 630.13959, 630.13952, 630.13953 manual INSTALLATION IID. Water connection

Page 6
INSTALLATION

INSTALLATION

IID. Water connection

Install according to national and local codes.

Carefully place dishwasher on its back to make water connections to the water inlet valve. Use a 90º elbow fitting with Teflon tape as needed. Don’t overtighten.

Attach the hot water line to the 90° elbow and route it underneath the unit toward the hot water connection. Make sure the line doesn’t contact any moving parts.

IIE. Drain and condensation hose connections

Plumbing installations will vary - refer to local codes. The maximum length of the drain hose, including leading to an air gap (if any) is 150" (381 cm). Make sure a high loop is raised at least 20" (51 cm) above the floor.

Drain hose has its own adapter – connect directly to plumbing connection and secure with supplied hose clamp. Don’t connect to condensation hose.

702_58300000149896_ara_en_b

Image 6
Contents Hoffman Estates, IL 60179 U.S.A KENMORE ELITE DISHWASHERSSears Brands Management Corporation Toronto, Ontario, Canada M5B 2C3WIRING DIAGRAMS FAULT DIAGNOSTICSTECHNICAL SPECIFICATIONS COMPONENTSIA. General hazards m I. SAFETYSAFETY IB. Electrical shock / fire hazards c hIIA. Pre-Installchecklist II. INSTALLATIONINSTALLATION IIB. AlignmentIIC. Electrical connection INSTALLATION IID. Water connection IIE. Drain and condensation hose connectionsSanitized and Refill Rinse Agent lights Reset “Cancel – Reset”III. OPERATION Dry AssistEnd of cycle tone Changing basic featuresThe End of cycle tone volume can be changed IIIC. Entering special programs and codingP4 = Control coding see CX control codes EX Error codesPX Program codes CX Control codesPreparing a dishwasher for showroom use Preparing a showroom dishwasher for resaleWARNING: Danger of electrical shock Adjusting rinse-aiddosage DispenserClosing dispenser doors Heater Operation IV.COMPONENTSTank Heater ratingsMicroswitch Cam Water switchLeveling feet front and rear DiskCirculation pumps BLDCFloat Drain pump Pump specificationsSolving installation issues CavitatingWater fill assembly Terminal connections Rast 5 connectorsJohnson Tee installations Washington State SiphoningFlowmeter Using hinge slider sliding pulley Condensation tubeDoor spring Hinge bushing Water inlet valveTerminal block On/off switchDoor latch Terminal boxDrain hose Optical rinse-aidsensors Power module Display and power modulesAqua sensor Control moduleSump parts SumpBackflow check valve Spray arm feed tube Info lightsOperation Water circulationSerial label warranty information Understanding the 17-digitserial #Tools needed: T20 Torx screwdriver V. RepairTo remove outer door To remove toe kickTo flip dishwasher upside-down To raise block up right side of tank Tools needed: T20 Torx screwdriver and pliersTools needed: T20 Torx screwdriver & pliers For access to circulation pumpTo remove water valve Connection hintsFascia panel mounted controls To remove complete pumpTools needed: flat blade screwdriver Tools needed: T-20Torx & flat blade screwdriversTools needed: T-20Torx screwdriver & pliers To access base-mountedcontrolsBase mounted controls 1.Remove outer door – see section VAFor access to heaters & NTC’s To remove heater, NTC & flow switchVE. Heaters Softer bearing heaters 4.Push NTC latches and lift NTC from heaterRepair VF. 2-piecedrain hose connection To remove dispensers1.Remove outer door --section VA VG. Drain pumpsTo remove door latches 1.Remove fascia panel --section VDVI. Door latches Misaligned door latches Fault Diagnostics VI.Fault DiagnosticsEntering customer service test program VIA. Customer service test programError code displays Clearing error codesViewing customer service program SymbolFailure Resolution Dishwasher troubleshootingFault Steps to determine failureDispenser or does not Heater diagnosingWill not fill fill withHeating system checklist if controls time out Controls timing out and showing “1”NTC resistance chart Where to measure NTC resistancesWater Leaking Past Doors Checklist if water leaks past doorsCosmetic / Customer Use / Installation Issues Not cleaning or locking sump filtersCustomer self-helpdiagnosing VII. Technical Specifications Technical SpecificationsUnsatisfactory washing results VIII. Wiring Diagrams Wiring DiagramsWiring Diagrams 702_58300000149896_ara_en_b