Is the resistance value | Yes | Normal | |
between pins 10(WH) | |||
|
| ||
And 4(BL) of CON3 |
|
| |
|
| ||
like as below? |
|
|
|
|
|
|
|
| pin10 WH |
|
| |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
| pin4 BL |
|
| |
|
|
|
|
|
|
| |||
| Resistance |
|
| ||||||
|
|
|
|
|
|
| |||
| Test Point |
|
|
| Ressult |
|
| ||
|
|
|
|
|
| ||||
| (1) To (2) |
| 34 ~ 42 Ω |
|
| ||||
|
|
|
|
|
|
|
|
| |
| No |
|
|
|
|
|
| ||
Is the connection loose? |
|
|
|
|
|
| |||
|
| Yes |
| Reconnect | |||||
|
|
|
|
|
|
|
|
|
|
No |
|
| |
|
|
| |
Is the resistance value | No | Replace | |
of Fuse |
| ||
|
| ||
|
| ||
as below? |
|
|
(1)BL
(2)BN
Open or Short of Fuse-M
Test Point | Ressult |
|
|
(1) To (2) | 0 Ω |
|
|
Yes
Is the resistance value of | No | Replace | |
Heater | |||
heater like as below? |
| ||
|
|
|
|
| (1) (2) |
| ||
| Heater Resistance |
|
| |||
|
|
|
|
| ||
| Test Point |
| Ressult |
|
| |
|
|
|
|
|
| |
| (1) To (2) |
| 34 ~ 42 Ω |
|
| |
|
|
|
|
|
| |
| Yes |
|
|
| ||
|
|
|
|
|
| |
Is the resistance | No | Replace | ||||
value of | ||||||
| ||||||
|
|
| ||||
as below? It depends on |
|
|
| |||
the temperature. |
|
|
|
|
|
|
|
|
| (1) BO |
|
|
|
|
|
| |
|
|
|
|
|
| (2) BO |
Defrost Sensor Resistance |
|
| ||||
|
|
|
|
|
|
|
Test Point | Result | Test Point |
| Result | ||
|
|
|
|
|
|
|
129.3 kΩ | 10°C |
| 19.53 kΩ | |||
|
|
|
|
|
|
|
76.96 kΩ | 20°C |
| 13.03 kΩ | |||
|
|
|
|
|
|
|
47.34 kΩ | 30°C |
| 8.896 kΩ | |||
|
|
|
|
|
|
|
0°C | 30 kΩ | 40°C |
| 6.201 kΩ | ||
|
|
|
|
|
|
|
Yes
Explain to the customer! :
It can be occurred, when the gasket is not stuck to product or when you put the high temperature loads (hot foods) a lot
in the product.
- 23 -