Icing Room Sensor Error
CON101
Display 1 | |
PCB | 2 |
|
Icing-Sensor
BL | 1 | 1 | BL |
|
| ||
BL | 2 | 2 | BL |
|
| ||
|
|
|
Wiring diagram
Is
Yes |
|
|
|
|
|
| |
Is the connection loose? | Yes | Reconnect | |
|
|
| |
Display PCB | Inner of Icing door |
No |
|
Disconnect CON101 and |
|
Replace | |
measure the value. Is resistance No | Main PCB |
value between pins 1 & 2 of |
|
| |
CON101 as below? (BL to BL) |
|
Is resistance value between
pins 1 & 2 of Housing- A as No below? (BL to BL)
pin1 BL pin2 BL
Checking Open or Short of wire
Test Point | Result |
(1)To (2) 1.4 ~120k‰
Yes
Reconnect and Power ON
Replace the
pin2 BL pin1 BL
Icing room Sensor Resistance
Test Point | Result |
pin1 to pin2 1.156 ~141.5k‰
If the
Yes