1. SPECIFICATIONS
IMPORTANT – RECONNECT ALL GROUNDING DEVICES
All parts of this appliance capable of conducting electrical current are grounded. If grounding wires, screws, straps, clips, nuts or washers used to complete a path to ground are removed for service, they must be returned to their original position and properly fastened.
1-2 IMPORTANT NOTICE
This information is intended for use by individuals possessing adequate backgrounds of electrical, electronic and mechanical experience. Any attempt to repair a major appliance may result in personal injury and property damage. The manufacturer or seller cannot be responsible for the interpretation of this information, nor can it assume any liability in connection with its use.
1-3 ELECTRICAL SPECIFICATIONS
Temperature Control (F |
| |
Defrost Control | Total Comp Running Time 7 hrs | |
Defrost Thermostat | 46°F | |
Electrical Rating : 115VAC, 60Hz | ||
Maximum Current Leakage | 0.5 mA | |
Maximum Ground Path Resistance | 0.14 Ohms | |
Energy Consumption | 25 cu.ft. 579 kWh/yr (Energy Star) |
1-4 NO LOAD PERFORMANCE CONTROL POSITION: MID/MID
And Ambient of: | 70°F | 90°F |
Fresh Food, °F | 33°F to 41°F | 33°F to 41°F |
Frozen Food, °F | ||
Percent Running Time |
1-5 REFRIGERATION SYSTEM
Minimum Compressor Capacity Vacuum | ............... 21 MIN. |
Minimum Equalized Pressure |
|
@ 70°F | 49 PSIG |
@ 90°F | 56 PSIG |
Refrigerant R134a | 4.41 oz. |
Compressor | 956 BTU/hr |
1-6 INSTALLATION
Clearance must be provided at top, sides and rear of the
refrigerator for air circulation. |
|
AT TOP | 2 in |
AT SIDES | 1 in |
AT REAR | 1 in |
1-7 REPLACEMENT PARTS
Relay | |
Overload | |
Defrost Thermostat | 6615JB2005H |
Defrost Heater | 5300JK1005D |
Evaporator Fan Motor | 4681JK1004E |
Capacitor (Running) | 0CZZJB2014B |
| *0CZZJB2012H |
| *0CZZJB2012K |
Compressor | TCA31748001 |
Evaporator | 5421JJ1007A |
Condenser | 5403JJ1004B |
Dryer | 5851JA2002P |
Condenser Fan Motor | 4681JB1029D |
Temperature Control | 3551JA1132L(SW) |
| 3551JA1132M(ST) |
| 3551JA1132N(WB) |
| 3551JA1132P(BI) |
Main Control | EBR3491102 |
Ice Fan Motor | 4681JB1029E |
*OPTIONAL |
|
EVAPORTOR FAN MOTOR
CONDENSER FAN MOTOR
ICE
ROOM