6-3. Troubleshooting Else
CUBE Mode doesn’t work
|
|
|
|
| |||
|
| BK |
|
| BK |
|
|
CON2 |
| 2 | 2 |
|
|
| |
3 |
|
| S | CUBE | |||
|
|
|
|
| |||
|
|
|
|
| Solenoid | ||
|
|
| 1 | 1 | BK | ||
|
|
|
|
| |||
| 5 | SB |
|
| BK |
|
|
Dispenser |
|
| 4 | 1 |
| V | Auger |
|
|
|
|
| |||
PCB | 7 |
| 7 | 2 | BK | Motor | |
Lever S/W |
| ||||||
|
|
| |||||
|
|
|
|
|
|
| |
CON3 | 3 | WH |
|
|
| ||
|
|
|
|
|
| ||
| 9 | RD | 1 | 1 | RD |
|
|
|
|
|
|
| |||
|
|
|
| Solenoid | |||
|
|
|
|
| S | ||
|
| BL |
|
| Dispenser | ||
|
| 2 | 2 |
|
|
| |
|
|
| BL |
|
| ||
|
|
|
|
|
|
| |
|
| Wiring diagram |
|
|
|
|
|
Dispenser PCB | Yes | |
Is the connection loose? | ||
|
No
Reconnect
In CUBE Mode,
Is the voltage between pin3 No of CON2 and pin3 of CON3
like as below, while pushing the lever switch?
Replace
Dispenser
PCB
CON2
Pin3 BK
CON3
Pin3 WH
Relay open of cube solenoid
Level switch | Test Point | Result |
|
|
|
Pushing | pin3 to pin3 | 115 V |
|
|
|
Normal | pin3 to pin3 | 0 ~ 2 V |
|
|
|
Yes
- 29 -