Toro TWRS manual Wiring Procedure II no sensor feature, Normally-open Sensor

Page 9

For a normally-opensensor, attach the Yellow wire to the remaining sensor terminal. Tape back the Brown wire. See Figure 3.

4.Attach the Red wires to the 24 Vac terminals. Important Most controllers with sensor connections also provide a control switch to bypass sensor operation if necessary. Check the switch setting to make sure it is not in the Bypass or Active position.

Wiring Procedure II (no sensor feature)

1.Locate the valve common wire terminal, generally labeled “C” or “COM”, and remove all common wires for valves, pump relay, etc.

2.Attach the White wire to this terminal.

3.Splice the Brown wire to the common wires and insulate the connection using a wire nut or electrical tape. Tape back the Yellow wire. See Figure 4.

4. Attach the Red wires to the 24 Vac terminals.

Figure 3 - Normally-open Sensor

 

 

 

 

 

 

PUMP/

 

SENSOR

24 VAC

 

1

2

3

4

MV

COM

 

 

 

 

 

 

 

Yellow

White

Red

Red

Red

 

 

 

 

 

 

 

 

 

 

To Valves

 

 

 

 

 

 

 

Red

 

 

 

 

 

 

 

 

 

 

White

 

 

 

 

 

 

 

 

 

 

Yellow

 

 

 

 

 

 

 

 

 

X

Brown

Figure 4 - Splice Valve Common

 

 

1

2

3

4

PUMP/MV

COM

24 VAC

 

 

 

 

 

 

White

Red

Red

 

 

 

 

 

 

 

 

 

Red

 

 

 

 

 

 

 

 

Red

Common

 

 

 

 

 

White

 

 

 

 

 

Brown

To Valves and

 

 

 

X

Yellow

Pump/MV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

Image 9
Contents User’s Guide Contents Page Here’s all there is to it Getting StartedStep Receiver Module Features Installing the Receiver Module Wiring Procedure I sensor-ready Connecting the Receiver WiresNormally-open Sensor Wiring Procedure II no sensor featureLeast of 15 seconds to establish communication Initial System TestSensor Module Features Installing the Sensor Module 1/4 Washer Freeze Sensor Site Selection Set Temperature Activation Threshold Twrfs models only Select Temperature ThresholdSelect Temperature Scale Page Water Delay Feature Smart Bypass FeatureSignal Strength Display Battery Strength DisplayRefer to Sensor Module Battery Replacement on Fail Safe Feature Dry Out FeatureLoss of communication Prolonged Active ModeTurn the Receiver Module Off and On Set or Restore the Sensor Address CodeUnscrew and remove the bottom cap from the sensor housing Sensor Module Battery ReplacementTroubleshooting Solving Reception ProblemsTo improve signal strength Sensor module does not activate the receiver at close range Receiver display is blankSpecifications Toro Promise Five-year Limited Warranty FCC ID OF7TWRS