Toshiba LF414 manual - 28 -, 6F8A0870, 1 Bolt length and Nut tightening torque

Page 29
Table 4.1 Bolt length and Nut tightening torque

6F8A0870

Table 4.1 Bolt length and Nut tightening torque

 

 

 

 

 

ASME B 16.5 class 150

 

ASME B 16.5 class 300

 

Meter size

Through Bolts

Tightening

Through Bolts

Tightening

 

P.C.S

Dia-

Length

torque

P.C.S

Dia-

Length

torque

 

 

 

 

 

 

 

 

meter

[mm]

[Nm]

meter

[mm]

[Nm]

 

15mm

1/2”

4

 

1/2”

150

 

12 to 15

4

1/2”

155

25 to 31

 

25mm

1”

4

 

1/2”

170

 

21 to 26

4

5/8”

180

53 to 66

 

40mm

1 1/2”

4

 

1/2”

195

 

32 to 40

4

3/4”

215

96 to 120

 

50mm

2”

4

 

5/8”

215

 

52 to 65

8

5/8”

220

52 to 65

 

80mm

3”

4

 

5/8”

225

 

71 to 88

8

3/4”

240

85 to 106

 

100mm

4”

8

 

5/8”

235

 

52 to 65

8

3/4”

255

125 to 156

 

150mm

6”

8

 

3/4”

355

 

104 to 130

12

3/4”

375

138 to 173

 

200mm

8”

8

 

3/4”

430

 

146 to 183

12

7/8”

460

227 to 284

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EN 1092-1 PN 10/16

 

 

JIS B 2220 10K

 

Meter size

 

Through Bolts

 

Tightening

 

Through Bolts

Tightening

 

 

P.C.S

 

Dia-

 

Length

 

torque

 

P.C.S

Dia-

Length

torque

 

 

 

 

 

 

 

 

 

 

 

 

 

meter

 

[mm]

 

[Nm]

 

meter

[mm]

[Nm]

 

15mm

 

4

 

M12

 

150

 

16 to 19

 

4

M12

150

10 to 13

 

25mm

 

4

 

M12

 

165

 

27 to 34

 

4

M16

170

22 to 28

 

40mm

 

4

 

M16

 

190

 

58 to 72

 

4

M16

190

32 to 40

 

50mm

 

4

 

M16

 

205

 

78 to 98

 

4

M16

200

43 to 53

 

80mm

 

8

 

M16

 

210

 

54 to 67

 

8

M16

210

27 to 34

 

100mm

 

8

 

M16

 

220

 

79 to 99

 

8

M16

215

37 to 46

 

150mm

 

8

 

M20

 

340

 

164 to 205

 

8

M20

340

70 to 88

 

200mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EN 1092-1

 

8

 

M20

 

410

 

146 to 183

 

12

M20

410

60 to 75

 

PN 10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EN 1092-1

 

12

 

M20

 

410

 

156 to 195

 

 

 

 

 

 

PN 16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- 28 -

Image 29
Contents 6F8A0870 - 1 - 6F8A0870About Safety Precautions Integral type LF414/LF600F, LF414/LF610F, LF414/LF620FExplanation of signal words SAFETY PRECAUTIONSSafety symbols - 2 -- 3 - SAFETY PRECAUTIONS Safety Precautions for Installation and WiringDON’T „ Do not modify or disassemble the enclosureSafety Precautions for Installation and Wiring SAFETY PRECAUTIONS continuedDON’T - 4 -Warranty and Limitation of Liability Safety Precautions for Maintenance and InspectionUsage limitation - 5 -- 6 - Handling Precautions・Places where excessive vibration or mechanical shock occurs 2 Wire cables correctly and securely- 7 - Handling Precautions continued- 8 - Table of Contents1.1 Product Inspection 1. Product Inspection and Storage1.2 Strage - 9 -2. Overview Features- 10 - 5 Intelligent functions3.1 Appearance 3. Names of Parts3.1.1 Appearance of LF414/LF600F, LF414/LF610F Integral 1 Meter size of 1/2 inch 15mm- 12 - 2 Meter size of 1inch 25mmFigure 3.1.2 Appearance of LF414/LF600F, LF610F Meter size 1 inch25mm Ground terminal for converter- 13 - 3 Meter size of 1 1/2 to 4 inch 40 to 100mmFigure 3.1.3 Appearance of LF414/LF600F, LF610F Meter size 1 1/2 to 4 inch 40 to 100mm- 14 - 4 Meter size of 6 and 8 inch 150 and 200mmLifting Lugs provided- 15 - 3.1.2 Appearance of LF414/LF620FFigure 3.1.5 Appearance of LF414/LF620F Meter size 1/2inch15mm Ground terminal for converter Flow direction arrow DetectorGround terminal for converter Flow direction arrow - 16 -Figure 3.1.6 Appearance of LF414/LF620F Meter size 1 inch25mm Figure 3.1.7 Appearance of LF414/LF620F - 17 -Figure 3.1.8 Appearance of LF414/LF620F - 18 -Meter size 6 and 8 inch 150 and 200mm Ground terminal for converter Lifting LugsSeparate 1 Meter size of 1/2 inch 15mm 3.1.3 Appearance of LF414- 19 - Signal cablefor Signal cable - 20 -Figure 3.1.10 Appearance of LF414 Meter size 1 inch25mm for Excitation cableSignal cable - 21 -Figure 3.1.11 Appearance of LF414 Excitation cableMeter size 6 and 8 inch150 and 200mm - 22 -Figure 3.1.12 Appearance of LF414 3.2 Construction of the terminal blocks Signal cable terminal3.2.2 Terminal Block Construction of LF414 Type - 23 -Safety Precautions for Installation 4. Installation- 24 - „ Use an appropriate device to carry and install4.2 Mounting Procedure 4.2.1 Pipe checks 4.1 Notes on Selecting the Installation Location- 25 - 2. Avoid places where excessive pipe vibration occursFigure 4.3 Model Diagram of Unsupported Pipes - 26 -Figure 4.2 Example of Pipe Fixing Procedure Figure 4.4 LF414 flowmeter detector piping connections 4.2.2 Installation Procedure- 27 - Table 4.1 Bolt length and Nut tightening torque - 28 -1b Optional “Mount Anywhere” Installation Mount-Anywhere Technology 1a Ideal Upstream Straight Pipe Length Installation Requirements4.3 Piping Connections L=5D- 30 - 2 Pipe OrientationFigure 4.6 Installation position of the detector Figure 4.5 Detector Piping Orientation4 Preventing an Empty Pipe Condition 3 Flow Direction- 31 - Figure 4.7 Flow direction arrow on the detector1 Grounding of the LF414/LF620F type 4.4 Grounding- 32 - Figure 4.10 Grounding the LF414/LF620F Type- 33 - 2 Grounding of the LF414 type- 34 - 5.WiringSafety Precautions for Wiring - 35 - 6F8A0870„ Install a switch and fuse to isolate the independently from power equipment. 100 ohm5.1 Cables Notes on wiring- 36 - Table 5.1 Installation Cables5.3.2 Notes on Wiring of the Separate type LF414 5.3 Notes on Wiring 5.3.1 Notes on Instrumentation-Converter Wiring5.2 External Device Connections and Grounding - 37 -1 Power cable, current output cable, digital I/O cables 5.4 Wiring 5.4.1 Terminal Treatment of CablesSeparate 2 Excitation cable - 38 -Notes on signal cable shield processing work 3 Connecting the input signal cable- 39 - Figure 5.3 Terminal Treatment of Flow Rate Signal CableFigure 5.5 Connecting a Cable to Terminal Block 5.4.2 Cable Connection- 40 - Preparatory check 6. Operation- 41 - „ Check the wiring between the converter and related instrumentsSafety precaution for Maintenance and Troubleshooting 7. Maintenance and Troubleshooting- 42 - „ Do not conduct wiring work when power is applied„ Cleaning 7.1 MaintenanceCheck/Replacement of the display unit materials7.2.1 Flow rate is not indicated 7.2 Troubleshooting- 44 - START Are power supplies correct NO for each device? YES- 45 - 7.2.2 Flow rate indicated is not correctPerform the zero adjustment Refer to combined converters manual Clean the inside of the detector pipe- 46 - 7.2.3 Flow rate indication is not stableIs power supply voltage Use a power supply within the specified rangeSquare-Wave Excitation Figure 8.1 Principle of Operation 8. Principle of Operation- 47 - 9.1Specifications 9. Specifications- 48 - Measurement range in terms of flow velocityFigure 9.1 Electrical Conductivity vs. Cable Length - 49 -Electrical conductivity μS/cm Table 9.1 Standard Flow Range - 50 -Table 9.2 Flow velocity vs. flow volume - 51 -Unit gal/min Unit m3/h9.2 Type Specification Code Table 9.3 Type Specification Code- 52 - Exciting cable length Nominal cross-sectional area Overall diameter Table 9.4 Type Specification Code Exciting Cable and Signal Cable- 53 - 10.1 Outline dimensions of LF414/LF600F, LF414/LF610F 10. Outline Dimensions1 Meter size of 1/2 inch 15mm 2 Meter size of 1 inch 25mm- 55 - 3 Meter size of 1 1/2 to 8 inch 40 to 200mmWaight approx 9 lb 4kg 10.2 Outline dimensions of LF414/LF620F- 56 - - 57 - Waight approx 7 lb 3kg 10.3 Outline dimensions of LF414- 58 - - 59 - - 60 - Appendix 1-1 A system block diagram for LF414/LF600F, LF414/LF610F- 61 - 1-2 A system block diagram for LF414/LF620F- 62 - 2-1 A system block diagram for LF414Distributor Address Name - 63 -Phone number ( Product codeFCF50017