Toshiba LF414 SAFETY PRECAUTIONS continued, Safety Precautions for Installation and Wiring, Don’T

Page 5
SAFETY PRECAUTIONS (continued)

6F8A0870

SAFETY PRECAUTIONS (continued)

Safety Precautions for Installation and Wiring

Safety Precautions for Installation and Wiring CAUTION

„ Install a switch and fuse to isolate the

„ Use an appropriate device to carry and install

LF414/LF600F, LF414/LF610F,

the LF414/LF600F,LF414/LF610F,

LF414/LF620F and LF414 from mains

LF414/LF620F and LF414.

power.

Power supply from mains power

 

If this product falls to the ground,

 

 

 

can cause electric shock or

 

injury, or malfunction of or damage

DO

circuit break-down.

DO

to the product, can be caused.

 

 

„ Turn off mains power before„ Do not modify or disassemble the

conducting wiring work.

LF414/LF600F, LF414/LF610F, LF414/LF620F

 

 

and LF414 unnecessarily.

 

Wiring while power is applied

 

Modifying or disassembling this

 

can cause electric shock.

 

product can cause

DO

 

DON’T

electric shock, malfunction of or

 

damage to this product.

„Turn off mains power before working on „ Ground the LF414/LF600F, LF414/LF610F,

pipes.

 

LF414/LF620F and LF414 independently from

 

 

power equipment.

 

 

(100 ohm or less ground resistance)

 

Working on pipes while power

 

Operating this product

 

is applied can cause

 

without grounding can cause

DO

electric shock.

DO

electric shock or malfunction.

 

 

„ Do not conduct wiring work with bare

Use crimped terminal lugs for the terminal
hands.

 

board and GND terminal.

 

Remaining electric charge

 

Loose connections can cause

 

even if power is turned off can

 

electric shock, fire from

DON’T

still cause electric shock.

DO

excessive current or system

 

malfunction.

„Do not work on piping and wiring with wet hands.

Wet hands may result in electric shock.

DON’T

The label shown left is placed near the terminal board for power supply on the converter.

(A black border and symbol on yellow triangle) Be alert to electric shock.

- 4 -
Image 5
Contents 6F8A0870 - 1 - 6F8A0870About Safety Precautions Integral type LF414/LF600F, LF414/LF610F, LF414/LF620FExplanation of signal words SAFETY PRECAUTIONSSafety symbols - 2 -- 3 - SAFETY PRECAUTIONS Safety Precautions for Installation and WiringDON’T „ Do not modify or disassemble the enclosureSafety Precautions for Installation and Wiring SAFETY PRECAUTIONS continuedDON’T - 4 -Warranty and Limitation of Liability Safety Precautions for Maintenance and InspectionUsage limitation - 5 -- 6 - Handling Precautions・Places where excessive vibration or mechanical shock occurs 2 Wire cables correctly and securely- 7 - Handling Precautions continued- 8 - Table of Contents1.1 Product Inspection 1. Product Inspection and Storage1.2 Strage - 9 -2. Overview Features- 10 - 5 Intelligent functions3.1 Appearance 3. Names of Parts3.1.1 Appearance of LF414/LF600F, LF414/LF610F Integral 1 Meter size of 1/2 inch 15mm- 12 - 2 Meter size of 1inch 25mmFigure 3.1.2 Appearance of LF414/LF600F, LF610F Meter size 1 inch25mm Ground terminal for converter- 13 - 3 Meter size of 1 1/2 to 4 inch 40 to 100mmFigure 3.1.3 Appearance of LF414/LF600F, LF610F Meter size 1 1/2 to 4 inch 40 to 100mm- 14 - 4 Meter size of 6 and 8 inch 150 and 200mmLifting Lugs provided- 15 - 3.1.2 Appearance of LF414/LF620FFigure 3.1.5 Appearance of LF414/LF620F Meter size 1/2inch15mm Ground terminal for converter Flow direction arrow DetectorGround terminal for converter Flow direction arrow - 16 -Figure 3.1.6 Appearance of LF414/LF620F Meter size 1 inch25mm Figure 3.1.7 Appearance of LF414/LF620F - 17 -Figure 3.1.8 Appearance of LF414/LF620F - 18 -Meter size 6 and 8 inch 150 and 200mm Ground terminal for converter Lifting LugsSeparate 1 Meter size of 1/2 inch 15mm 3.1.3 Appearance of LF414- 19 - Signal cablefor Signal cable - 20 -Figure 3.1.10 Appearance of LF414 Meter size 1 inch25mm for Excitation cableSignal cable - 21 -Figure 3.1.11 Appearance of LF414 Excitation cableMeter size 6 and 8 inch150 and 200mm - 22 -Figure 3.1.12 Appearance of LF414 3.2 Construction of the terminal blocks Signal cable terminal3.2.2 Terminal Block Construction of LF414 Type - 23 -Safety Precautions for Installation 4. Installation- 24 - „ Use an appropriate device to carry and install4.2 Mounting Procedure 4.2.1 Pipe checks 4.1 Notes on Selecting the Installation Location- 25 - 2. Avoid places where excessive pipe vibration occursFigure 4.3 Model Diagram of Unsupported Pipes - 26 -Figure 4.2 Example of Pipe Fixing Procedure Figure 4.4 LF414 flowmeter detector piping connections 4.2.2 Installation Procedure- 27 - Table 4.1 Bolt length and Nut tightening torque - 28 -1b Optional “Mount Anywhere” Installation Mount-Anywhere Technology 1a Ideal Upstream Straight Pipe Length Installation Requirements4.3 Piping Connections L=5D- 30 - 2 Pipe OrientationFigure 4.6 Installation position of the detector Figure 4.5 Detector Piping Orientation4 Preventing an Empty Pipe Condition 3 Flow Direction- 31 - Figure 4.7 Flow direction arrow on the detector1 Grounding of the LF414/LF620F type 4.4 Grounding- 32 - Figure 4.10 Grounding the LF414/LF620F Type- 33 - 2 Grounding of the LF414 type- 34 - 5.WiringSafety Precautions for Wiring - 35 - 6F8A0870„ Install a switch and fuse to isolate the independently from power equipment. 100 ohm5.1 Cables Notes on wiring- 36 - Table 5.1 Installation Cables5.3.2 Notes on Wiring of the Separate type LF414 5.3 Notes on Wiring 5.3.1 Notes on Instrumentation-Converter Wiring5.2 External Device Connections and Grounding - 37 -1 Power cable, current output cable, digital I/O cables 5.4 Wiring 5.4.1 Terminal Treatment of CablesSeparate 2 Excitation cable - 38 -Notes on signal cable shield processing work 3 Connecting the input signal cable- 39 - Figure 5.3 Terminal Treatment of Flow Rate Signal CableFigure 5.5 Connecting a Cable to Terminal Block 5.4.2 Cable Connection- 40 - Preparatory check 6. Operation- 41 - „ Check the wiring between the converter and related instrumentsSafety precaution for Maintenance and Troubleshooting 7. Maintenance and Troubleshooting- 42 - „ Do not conduct wiring work when power is applied„ Cleaning 7.1 MaintenanceCheck/Replacement of the display unit materials7.2.1 Flow rate is not indicated 7.2 Troubleshooting- 44 - START Are power supplies correct NO for each device? YES- 45 - 7.2.2 Flow rate indicated is not correctPerform the zero adjustment Refer to combined converters manual Clean the inside of the detector pipe- 46 - 7.2.3 Flow rate indication is not stableIs power supply voltage Use a power supply within the specified rangeSquare-Wave Excitation Figure 8.1 Principle of Operation 8. Principle of Operation- 47 - 9.1Specifications 9. Specifications- 48 - Measurement range in terms of flow velocityFigure 9.1 Electrical Conductivity vs. Cable Length - 49 -Electrical conductivity μS/cm Table 9.1 Standard Flow Range - 50 -Table 9.2 Flow velocity vs. flow volume - 51 -Unit gal/min Unit m3/h9.2 Type Specification Code Table 9.3 Type Specification Code- 52 - Exciting cable length Nominal cross-sectional area Overall diameter Table 9.4 Type Specification Code Exciting Cable and Signal Cable- 53 - 10.1 Outline dimensions of LF414/LF600F, LF414/LF610F 10. Outline Dimensions1 Meter size of 1/2 inch 15mm 2 Meter size of 1 inch 25mm- 55 - 3 Meter size of 1 1/2 to 8 inch 40 to 200mmWaight approx 9 lb 4kg 10.2 Outline dimensions of LF414/LF620F- 56 - - 57 - Waight approx 7 lb 3kg 10.3 Outline dimensions of LF414- 58 - - 59 - - 60 - Appendix 1-1 A system block diagram for LF414/LF600F, LF414/LF610F- 61 - 1-2 A system block diagram for LF414/LF620F- 62 - 2-1 A system block diagram for LF414Distributor Address Name - 63 -Phone number ( Product codeFCF50017