Toshiba LF414 manual 3 Type Specification Code, - 52 -, 6F8A0870

Page 53
9.2Type Specification Code

6F8A0870

9.2Type Specification Code

Table 9.3 Type Specification Code

 

 

 

 

 

Specification Code

 

 

 

 

 

Description

 

 

1/2”to

 

6”

1

2

3

4

5

 

6

7

8

9

10

11

12

13

14

 

 

 

4”

 

and

 

 

 

 

 

 

8”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L

F

4

 

 

 

 

 

 

 

 

 

 

 

 

Electromagnetic Flowmeter

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

Style

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wafer type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Area of use

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Division 2 Hazardous Location

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

Meter size

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1/2"

(15mm )

 

 

 

 

 

 

 

 

 

 

 

E

 

 

 

 

 

 

 

 

1"

( 25mm )

 

 

 

 

 

 

 

 

 

 

 

F

 

 

 

 

 

 

 

 

1-1 /2"( 40mm )

 

 

 

 

 

 

 

 

 

 

 

G

 

 

 

 

 

 

 

 

2"

( 50mm )

 

 

 

 

 

 

 

 

 

 

 

H

 

 

 

 

 

 

 

 

3"

( 80mm )

 

 

 

 

 

 

 

 

 

 

 

J

 

 

 

 

 

 

 

 

4"

( 100mm )

 

 

 

 

 

 

 

 

 

 

 

K

 

 

 

 

 

 

 

 

6"

( 150mm )

 

 

 

 

 

 

 

 

 

 

 

L

 

 

 

 

 

 

 

 

8"

( 200mm )

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mounting Structure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hazardous location

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

cFMus, Division 2 approved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Detector/Converter combined type

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

Detector/Converter separate type

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

Connection flange standard

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ASME B 16.5 class 150

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

ASME B 16.5 class 300

 

 

 

 

 

 

 

 

 

 

 

G

 

 

 

 

 

 

EN 1092-1 PN10

 

 

 

 

 

 

 

 

 

 

 

H

 

 

 

 

 

 

EN 1092-1 PN16

 

 

 

 

 

 

 

 

 

 

 

J

 

 

 

 

 

 

JIS B 2220 10K

 

 

 

 

 

 

 

 

 

 

 

K

 

 

 

 

 

 

JIS B 2220 16K

 

 

 

 

 

 

 

 

 

 

 

L

 

 

 

 

 

 

JIS B 2220 20K

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

Electrode Material

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

316L stainless steel

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

Ti (titanium)

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

Pt-Ir (platinum/iridium)

 

 

 

 

 

 

 

 

 

 

 

 

E

 

 

 

 

 

Ta (tantalum)

 

 

 

 

 

 

 

 

 

 

 

 

F

 

 

 

 

 

Hastelloy C

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

Lining Material

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Alkali-resistant ceramic (alumina)

(standard)

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

Acid-resistant ceramic (alumina)

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

Teflon PFA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

Grounding Ring Material

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

316 stainless steel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

316L stainless steel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

 

 

Ti (titanium)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F

 

 

 

Ta (tantalum)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G

 

 

 

Pt-Ir (platinum/iridium)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H

 

 

 

Hastelloy C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

Flow and calibration velocity range

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.0 to 32.8 ft/s (0.3 to 10 m/s) (standard range calibration)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

1.0 to 32.8 ft/s (0.3 to 10 m/s) (specified range calibration)

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

0.3 to 32.8 ft/s (0.1 to 10 m/s) (specified range calibration)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

Excitation and Signal Cables

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

not provided

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

30m cable, provided

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

other lengths, provided

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

Coating

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

no coating ( Standard for meter size 1” to 4” )

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

phthalic acid resin coating pearl-gray colored

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

( Standard for meter size 1/2”, 6” and 8” )

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

black tar epoxy resin, thickness 0.3 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

black tar epoxy resin, thickness 0.5 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

○:Standard

△:Option

-:Not available

 

- 52 -

Image 53
Contents 6F8A0870 - 1 - 6F8A0870About Safety Precautions Integral type LF414/LF600F, LF414/LF610F, LF414/LF620FExplanation of signal words SAFETY PRECAUTIONSSafety symbols - 2 -- 3 - SAFETY PRECAUTIONS Safety Precautions for Installation and WiringDON’T „ Do not modify or disassemble the enclosureSafety Precautions for Installation and Wiring SAFETY PRECAUTIONS continuedDON’T - 4 -Warranty and Limitation of Liability Safety Precautions for Maintenance and InspectionUsage limitation - 5 -- 6 - Handling Precautions・Places where excessive vibration or mechanical shock occurs 2 Wire cables correctly and securely- 7 - Handling Precautions continued- 8 - Table of Contents1.1 Product Inspection 1. Product Inspection and Storage1.2 Strage - 9 -2. Overview Features- 10 - 5 Intelligent functions3.1 Appearance 3. Names of Parts3.1.1 Appearance of LF414/LF600F, LF414/LF610F Integral 1 Meter size of 1/2 inch 15mm- 12 - 2 Meter size of 1inch 25mmFigure 3.1.2 Appearance of LF414/LF600F, LF610F Meter size 1 inch25mm Ground terminal for converter- 13 - 3 Meter size of 1 1/2 to 4 inch 40 to 100mmFigure 3.1.3 Appearance of LF414/LF600F, LF610F Meter size 1 1/2 to 4 inch 40 to 100mm- 14 - 4 Meter size of 6 and 8 inch 150 and 200mmLifting Lugs provided- 15 - 3.1.2 Appearance of LF414/LF620FFigure 3.1.5 Appearance of LF414/LF620F Meter size 1/2inch15mm Ground terminal for converter Flow direction arrow DetectorGround terminal for converter Flow direction arrow - 16 -Figure 3.1.6 Appearance of LF414/LF620F Meter size 1 inch25mm Figure 3.1.7 Appearance of LF414/LF620F - 17 -Figure 3.1.8 Appearance of LF414/LF620F - 18 -Meter size 6 and 8 inch 150 and 200mm Ground terminal for converter Lifting LugsSeparate 1 Meter size of 1/2 inch 15mm 3.1.3 Appearance of LF414- 19 - Signal cablefor Signal cable - 20 -Figure 3.1.10 Appearance of LF414 Meter size 1 inch25mm for Excitation cableSignal cable - 21 -Figure 3.1.11 Appearance of LF414 Excitation cableMeter size 6 and 8 inch150 and 200mm - 22 -Figure 3.1.12 Appearance of LF414 3.2 Construction of the terminal blocks Signal cable terminal3.2.2 Terminal Block Construction of LF414 Type - 23 -Safety Precautions for Installation 4. Installation- 24 - „ Use an appropriate device to carry and install4.2 Mounting Procedure 4.2.1 Pipe checks 4.1 Notes on Selecting the Installation Location- 25 - 2. Avoid places where excessive pipe vibration occursFigure 4.3 Model Diagram of Unsupported Pipes - 26 -Figure 4.2 Example of Pipe Fixing Procedure Figure 4.4 LF414 flowmeter detector piping connections 4.2.2 Installation Procedure- 27 - Table 4.1 Bolt length and Nut tightening torque - 28 -1b Optional “Mount Anywhere” Installation Mount-Anywhere Technology 1a Ideal Upstream Straight Pipe Length Installation Requirements4.3 Piping Connections L=5D- 30 - 2 Pipe OrientationFigure 4.6 Installation position of the detector Figure 4.5 Detector Piping Orientation4 Preventing an Empty Pipe Condition 3 Flow Direction- 31 - Figure 4.7 Flow direction arrow on the detector1 Grounding of the LF414/LF620F type 4.4 Grounding- 32 - Figure 4.10 Grounding the LF414/LF620F Type- 33 - 2 Grounding of the LF414 type- 34 - 5.WiringSafety Precautions for Wiring - 35 - 6F8A0870„ Install a switch and fuse to isolate the independently from power equipment. 100 ohm5.1 Cables Notes on wiring- 36 - Table 5.1 Installation Cables5.3.2 Notes on Wiring of the Separate type LF414 5.3 Notes on Wiring 5.3.1 Notes on Instrumentation-Converter Wiring5.2 External Device Connections and Grounding - 37 -1 Power cable, current output cable, digital I/O cables 5.4 Wiring 5.4.1 Terminal Treatment of CablesSeparate 2 Excitation cable - 38 -Notes on signal cable shield processing work 3 Connecting the input signal cable- 39 - Figure 5.3 Terminal Treatment of Flow Rate Signal CableFigure 5.5 Connecting a Cable to Terminal Block 5.4.2 Cable Connection- 40 - Preparatory check 6. Operation- 41 - „ Check the wiring between the converter and related instrumentsSafety precaution for Maintenance and Troubleshooting 7. Maintenance and Troubleshooting- 42 - „ Do not conduct wiring work when power is applied„ Cleaning 7.1 MaintenanceCheck/Replacement of the display unit materials7.2.1 Flow rate is not indicated 7.2 Troubleshooting- 44 - START Are power supplies correct NO for each device? YES- 45 - 7.2.2 Flow rate indicated is not correctPerform the zero adjustment Refer to combined converters manual Clean the inside of the detector pipe- 46 - 7.2.3 Flow rate indication is not stableIs power supply voltage Use a power supply within the specified rangeSquare-Wave Excitation Figure 8.1 Principle of Operation 8. Principle of Operation- 47 - 9.1Specifications 9. Specifications- 48 - Measurement range in terms of flow velocityFigure 9.1 Electrical Conductivity vs. Cable Length - 49 -Electrical conductivity μS/cm Table 9.1 Standard Flow Range - 50 -Table 9.2 Flow velocity vs. flow volume - 51 -Unit gal/min Unit m3/h9.2 Type Specification Code Table 9.3 Type Specification Code- 52 - Exciting cable length Nominal cross-sectional area Overall diameter Table 9.4 Type Specification Code Exciting Cable and Signal Cable- 53 - 10.1 Outline dimensions of LF414/LF600F, LF414/LF610F 10. Outline Dimensions1 Meter size of 1/2 inch 15mm 2 Meter size of 1 inch 25mm- 55 - 3 Meter size of 1 1/2 to 8 inch 40 to 200mmWaight approx 9 lb 4kg 10.2 Outline dimensions of LF414/LF620F- 56 - - 57 - Waight approx 7 lb 3kg 10.3 Outline dimensions of LF414- 58 - - 59 - - 60 - Appendix 1-1 A system block diagram for LF414/LF600F, LF414/LF610F- 61 - 1-2 A system block diagram for LF414/LF620F- 62 - 2-1 A system block diagram for LF414Distributor Address Name - 63 -Phone number ( Product codeFCF50017