Orion 2xx manual Agency Approvals, Agency specifications Atex Intrinsically safe

Page 25

5.2Agency Approvals

AGENCY

MODEL

PROTECTION METHOD

AREA CLASSIFICATION

 

 

 

 

 

FM & CSA

2X1-XXXXXXX-XXX

Intrinsically Safe

Class I, Div. 1:

 

2X2-XXXXXXX-XXX

 

Groups A, B, C, & D

 

2X3-XXXXXXX-XXX

 

Class II, Div. 1:

 

2X4-XXXXXXX-XXX

 

Groups E, F, & G

 

 

 

Class III, IP66 TYPE 4X, T4

 

 

 

FISCO

 

 

2XX-XXXXXXX-XXX

Explosion Proof

Class I, Div. 1

 

 

 

Groups B, C, & D

 

 

 

Class II, Div. 1

 

 

 

Groups E, F, & G

 

 

 

Class III, IP66 Type 4X T5 at 80° C

 

 

2XX-XXXXXXX-XXX

Non-Incendive

Class I, Div. 2

 

 

 

Groups A, B, C, & D

 

 

 

Class II, Div. 2

 

 

 

Groups E, F, & G

 

 

 

Class III, IP66 Type 4X T5 at 80° C

 

ATEX

2XA-XXXXXXX-XXX

Flame Proof

II 1/2 G EExd IIC T6

 

2XB-XXXXXXX-XXX

 

 

 

 

2XC-XXXXXXX-XXX

 

 

 

 

2XD-XXXXXXX-XXX

 

 

 

 

2XE-XXXXXXX-XXX

Intrinsically Safe

II 1 G EEx ia IIC T4

 

2XF-XXXXXXX-XXX

 

FISCO

 

2XG-XXXXXXX-XXX

 

 

 

 

2XH-XXXXXXX-XXX

 

 

 

M20 conduit connections not CSA approved explosion proof FM approval Class II, Div. 2 Groups F & G only

Materials marked as category 1 equipment and used in hazardous areas requiring this category, shall be installed in such a way that, even in the event of rare incidents, the aluminum enclosure cannot be an ignition source due to impact or friction

5.2.1Agency Specifications – Explosion Proof Installation

Factory Sealed: This product has been approved by Factory Mutual Research (FM) and Canadian Standards Association (CSA) as a Factory Sealed device.

NOTE: Factory Sealed: No Explosion Proof conduit fitting (EY seal) is required within 18" of the transmitter. However, an Explosion Proof conduit fitting (EY seal) is required between the haz- ardous and safe areas.

Caution: Grounding (+) will cause faulty operation, but will not cause permanent damage.

5.2.2Agency specifications ATEX Intrinsically safe

Entity parameters Fieldbus Fisco:

Ui = 17.5V Ii=380mA Pi = 5.32W Ci = 0.705 nF Li = 3µH

46-649 Jupiter Magnetostrictive Transmitter - FOUNDATION fieldbus™

22

Image 25
Contents Magnetostrictive Level Transmitter Read this Manual Before Installing Table of Contents Description Foundation Fieldbus OverviewBenefits Device Configuration Device DescriptionsIntrinsic Safety Electrostatic Discharge ESD Handling Procedure InstallationUnpacking Site Preparation Before You BeginEquipment and Tools Mounting Configuration InformationOperational Considerations ExternalInternal, Direct Insertion Position the Jupiter transmitter on the side of the MLIWiring Overview Function BlocksUniversal Fieldbus Block Parameters Resource Block Jupiter Magnetostrictive Transmitter Foundation fieldbus Jupiter Magnetostrictive Transmitter Foundation fieldbus Transducer Block Password ParametersTransducer Block Parameters User Calibration Parameters Jupiter Configuration ParametersFactory Parameters Channels Analog Input BlockFirmware Version AI Block ParametersJupiter Magnetostrictive Transmitter Foundation fieldbus Diagnostic Parameters Simulation Feature Troubleshooting TroubleshootingReference Information Display Message Action Comment Status MessagesSize Length Type FF Segment ChecklistAgency Approvals Agency specifications Atex Intrinsically safeAgency Drawing Agency Drawing Functional SpecificationsPerformance Inches mm PhysicalParts Replacement PartsEnhanced Jupiter Magnetostrictive Transmitter Model NumbersNone, defines external mount Direct Insertion Total Level Float Selection References Appendix Transducer Block ParametersJupiter Magnetostrictive Transmitter Service Policy