Orion 2xx manual Direct Insertion Total Level Float Selection

Page 33

5.5Model Numbers

5.5.1Enhanced Jupiter Magnetostrictive Transmitter

FLOAT

The floats listed below are suitable for most applications. Consult factory for custom floats. For models with 2 floats, choose top float below, then consult factory for second float selection. For externally mounted models use float code “00”.

DIRECT INSERTION TOTAL LEVEL FLOAT SELECTION

Minimum Liquid

316/316L SS

 

Titanium

Hastelloy C

316/316L SS Sanitary

Specific Gravity

diameter length

diameter length

diameter length

diameter length

 

 

 

 

 

 

 

 

AA

2.00"

BA

CA

DA

0.84

2" 2.75" float

2.75" float

1.85" 3.00" float

2.00" 2.75" float

 

(50 70 mm)

(50

70 mm)

(47 76 mm)

(50 70 mm)

 

AB

2.00"

BA

CB

DB

0.70

2.30" 3.00" float

2.75" float

2.30" 3.00" float

2.30" 3.00" float

 

(58.5 76 mm)

(50

70 mm)

(58.5 76 mm)

(58.5 76 mm)

 

AC

 

 

BB

Custom float

Custom float

0.64

2.55" 3.00" float

2.30" 3.00" float

ordered separately

ordered separately

 

(65 76 mm)

(58.5 76 mm)

 

 

 

 

 

 

Custom float

 

 

BB

Custom float

Custom float

0.52

2.30" 3.00" float

ordered separately

ordered separately

ordered separately

 

(58.5 76 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIRECT INSERTION INTERFACE LEVEL FLOAT SELECTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum Liquid

316 SS

 

Titanium

Hastelloy C

316L SS

Specific Gravities

 

diameter length

diameter length

diameter length

diameter length

A/B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

.89/1.00

MA

 

 

NA

PA

QA

2.00" 2.75" float

2.00" ¥ 2.75" float

1.85" 3.00" float

2.00" 2.75" float

 

(50 70 mm)

(50 ¥ 70 mm)

(47 76 mm)

(50 70 mm)

1.00/1.12

MB

2.30"

NB

PB

QB

2.00" 2.75" float

3.00" float

1.85" 3.00" float

2.00" 2.75" float

 

(50 70 mm)

(58.5 76 mm)

(47 76 mm)

(50 70 mm)

OTHER FLOAT SELECTION

 

 

PROBE LENGTH

 

No float when used with MLI

 

 

 

 

 

 

00

 

 

 

 

 

Specify measuring range in:

 

Custom float—consult factory

 

 

 

Inches when tenth digit is Code “E”, lengths from 6 to 400 inches

 

 

 

 

 

 

 

 

 

Pressure / Temperature

 

Inch Code Example: 24 inches = Code 024

 

400

 

Specify measuring range in:

 

 

 

 

 

 

 

 

 

 

 

 

Centimeters when tenth digit is Code “M”, lengths from 15 to 999 cm

 

350

 

 

 

316/316L SS

 

 

 

 

Hastelloy C 276

Centimeter Code Example: 60 cm = Code 060

 

 

 

 

 

 

300

 

 

 

Titanium CP2

 

 

 

 

Float is weighted to sink through

PSIG

250

 

 

 

 

 

200

 

 

 

 

 

specific gravity A and float on

 

 

 

 

 

 

 

150

 

 

 

 

 

specific gravity B

 

 

 

 

 

 

The bottom 3 inches of SIL 2 direct

 

100

 

 

 

 

 

 

 

 

 

 

 

insertion probes are inactive. The inactive

 

50

 

 

 

 

 

 

 

 

 

 

 

area is used to detect float failure.

 

0

 

 

 

 

 

 

 

0

100

200

300

400

500

 

 

 

 

Temperature °F

 

 

 

2

 

 

 

 

 

 

 

46-649 Jupiter Magnetostrictive Transmitter - FOUNDATION fieldbus™

30

Image 33
Contents Magnetostrictive Level Transmitter Read this Manual Before Installing Table of Contents Description Foundation Fieldbus OverviewBenefits Device Configuration Device DescriptionsIntrinsic Safety Installation Electrostatic Discharge ESD Handling ProcedureUnpacking Before You Begin Site PreparationEquipment and Tools Mounting Configuration InformationOperational Considerations ExternalInternal, Direct Insertion Position the Jupiter transmitter on the side of the MLIWiring Function Blocks OverviewUniversal Fieldbus Block Parameters Resource Block Jupiter Magnetostrictive Transmitter Foundation fieldbus Jupiter Magnetostrictive Transmitter Foundation fieldbus Password Parameters Transducer BlockTransducer Block Parameters Jupiter Configuration Parameters User Calibration ParametersFactory Parameters Channels Analog Input BlockFirmware Version AI Block ParametersJupiter Magnetostrictive Transmitter Foundation fieldbus Diagnostic Parameters Simulation Feature Troubleshooting TroubleshootingReference Information Display Message Action Comment Status MessagesSize Length Type FF Segment ChecklistAgency Approvals Agency specifications Atex Intrinsically safeAgency Drawing Agency Drawing Specifications FunctionalPerformance Inches mm PhysicalParts Replacement PartsEnhanced Jupiter Magnetostrictive Transmitter Model NumbersNone, defines external mount Direct Insertion Total Level Float Selection References Appendix Transducer Block ParametersJupiter Magnetostrictive Transmitter Service Policy