Orion 2xx manual Model Numbers, Enhanced Jupiter Magnetostrictive Transmitter

Page 31

5.5Model Numbers

5.5.1Enhanced Jupiter Magnetostrictive Transmitter

TRANSMITTER TYPE

2

Enhanced Jupiter Magnetostrictive

OUTPUT

4

LCD display, 4–20 mA & HART, SIL 1

 

 

5

LCD display & FOUNDATION Fieldbus

6

LCD display, 4–20 mA & HART, SIL 2

7

Interface transmitter, 4–20 mA & HART, with LCD display, 2 floats

 

 

8

Interface transmitter, FOUNDATION Fieldbus, with LCD display, 2 floats

 

 

HOUSING MATERIAL, MOUNTING AND CONDUIT ENTRY

1

Cast Aluminum, Integral Mount with 34" NPT Conduit Entry

FM, EP, NI & IS

2

Cast Aluminum, Integral Mount with M20 Conduit Entry

FM, EP,NI & IS

3

316

SS, Integral Mount with 34" NPT Conduit Entry

FM, EP,NI & IS

4

316

SS, Integral Mount with M20 Conduit Entry

FM, EP,NI & IS

A

Cast aluminum, Integral Mount with 34" NPT conduit entry

ATEX, EEx d

B

Cast aluminum, Integral Mount with M20 conduit entry

ATEX, EEx d

 

 

 

 

C

316

SS, Integral Mount with 34" NPT conduit entry

ATEX, EEx d

D

316 SS, Integral Mount with M20 conduit entry

ATEX, EEx d

E

Cast aluminum, Integral Mount with 34" NPT conduit entry

ATEX, EEx ia

F

Cast aluminum, Integral Mount with M20 conduit entry

ATEX, EEx ia

G

316

SS, Integral Mount with 34" NPT conduit entry

ATEX, EEx ia

H

316

SS, Integral Mount with M20 conduit entry

ATEX, EEx ia

 

 

 

 

CONFIGURATION (see drawings on page 34)

D Direct Insertion, Construction codes 1 through 7

E Top Mount, Construction code 1

F Top Mount Offset, Construction code 1

G Top Mount Offset, high-temperature bend, Construction code 7

H Bottom Mount Offset, Construction code 1

J Bottom Mount Offset, high-temperature bend, Construction code 7

MATERIALS OF CONSTRUCTION

1 316/316L SS (standard), +250° F (+120° C) Maximum (Direct Insertion +200° F (+95°))

7 316/316L SS (high temperature) +500° F (+260° C) Maximum

2 Hastelloy® C, +200° F (+95° C) Maximum

3 Monel®, +200° F (+95° C) Maximum

5 Electropolished 316/316L SS, +200° F (+95° C) Maximum

6 Sanitary 316/316L SS, +200° F (+95° C) Maximum

MOUNTING CONNECTION

See page 29

2

FLOAT

See page 29

 

PROBE UNITS

 

E

Inches

M

Centimeters

 

INSERTION LENGTH

 

See page 30

The bottom 3 inches of SIL 2 direct insertion probes are inactive. The inactive area is used to detect float failure.

Consult factory for process temperatures of 500°–850° F (260°–455° C)

Direct insertion model only. Consult factory for process temperatures above +200° F (+95° C)

46-649 Jupiter Magnetostrictive Transmitter - FOUNDATION fieldbus™

28

Image 31
Contents Magnetostrictive Level Transmitter Read this Manual Before Installing Table of Contents Description Foundation Fieldbus OverviewBenefits Device Configuration Device DescriptionsIntrinsic Safety Electrostatic Discharge ESD Handling Procedure InstallationUnpacking Site Preparation Before You BeginEquipment and Tools External Configuration InformationMounting Operational ConsiderationsInternal, Direct Insertion Position the Jupiter transmitter on the side of the MLIWiring Overview Function BlocksUniversal Fieldbus Block Parameters Resource Block Jupiter Magnetostrictive Transmitter Foundation fieldbus Jupiter Magnetostrictive Transmitter Foundation fieldbus Transducer Block Password ParametersTransducer Block Parameters User Calibration Parameters Jupiter Configuration ParametersFactory Parameters AI Block Parameters Analog Input BlockChannels Firmware VersionJupiter Magnetostrictive Transmitter Foundation fieldbus Diagnostic Parameters Simulation Feature Troubleshooting TroubleshootingReference Information Display Message Action Comment Status MessagesSize Length Type FF Segment ChecklistAgency Approvals Agency specifications Atex Intrinsically safeAgency Drawing Agency Drawing Functional SpecificationsPerformance Inches mm PhysicalParts Replacement PartsEnhanced Jupiter Magnetostrictive Transmitter Model NumbersNone, defines external mount Direct Insertion Total Level Float Selection References Appendix Transducer Block ParametersJupiter Magnetostrictive Transmitter Service Policy