Multiquip DCA300SSC manual TIRES/WHEELS/LUG Nuts, Tire Wear/Inflation, Suspension

Page 44

TRAILER MAINTENANCE

TIRES/WHEELS/LUG NUTS

Tires and wheels are a very important and critical components of the trailer. When specifying or replacing the trailer wheels it is important the wheels, tires, and axle are properly matched.

CAUTION

ALWAYS wear safety glasses when removing or installing force fi tted parts. Failure to comply may result in serious injury.

CAUTION

DO NOT attempt to repair or modify a wheel. DO NOT install in inner tube to correct a leak through the rim. If the rim is cracked, the air pressure in the inner tube

may cause pieces of the rim to explode (break off) with great force and cause serious eye or bodily injury.

Tire Wear/Inflation

Tire infl ation pressure is the most important factor in tire life. Pressure should be checked cold before operation DO NOT bleed air from tires when they are hot!. Check inflation pressure weekly during use to insure the maximum tire life and tread wear.

Table 16 (Tire Wear Troubleshooting) will help pinpoint the causes and solutions of tire wear problems.

Table 14. Tire Wear Troubleshooting

 

 

Wear Pattern

Cause

Solution

 

 

 

 

 

 

 

 

 

 

 

Center Wear

Over infl ation.

Adjust pressure to particular

 

 

 

 

 

 

 

 

load per tire manufacturer.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Edge Wear

Under infl ation.

Adjust pressure to particular

 

 

 

 

 

 

 

 

load per tire manufacturer.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Loss of camber

Make sure load does not

 

 

 

 

 

 

 

 

 

Side Wear

exceed axle rating.

 

 

 

 

or overloading.

 

 

 

 

 

Align wheels.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Toe Wear

Incorrect toe-in.

Align wheels.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cupping

Out-of-balance.

Check bearing adjustment

 

 

 

 

 

 

 

 

and balance tires.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flat Spots

Wheel lockup and

Avoid sudden stops when

 

 

 

 

 

 

 

 

tire skidding.

possible and adjust brakes.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Suspension

The leaf suspension springs and associated components (Figure 61) should be visually inspected every 6,000 miles for signs of excessive wear, elongation of bolt holes, and loosening of fasteners. Replace all damaged parts (suspension) immediately.Torqued suspension components as detailed in Table 17.

Figure 61. Major Suspension Components

Table 15. Suspension Torque Requirements

Item

Torque (Ft.-Lbs.)

 

 

 

3/8" U-Bolt

Min-30

Max-35

 

 

 

7/16" U-Bolt

Min-45

Max-60

 

 

 

1/2" U-Bolt

Min-45

Max-60

 

 

Shackle Bolt

Snug fi t only. Parts must rotate freely.

Locking nuts or cotter pins are

Spring Eye Bolt

provided to retain nut-bolt assembly.

 

 

 

 

Shoulder Type

Min-30

Max-50

Shackle Bolt

 

 

 

 

 

PAGE 44 — DCA300SSC GENERATOR • OPERATION AND PARTS MANUAL — REV. #0 (06/25/09)

Image 44
Contents Model DCA300SSC This Manual Must Accompany the Equipment AT ALL TimesProposition 65 Warning Reporting Safety Defects NhtsaTable of Contents DCA300SSCParts Ordering Procedures Ordering parts has never been easierSafety Information Safety Messages Always know the location of the nearest General SafetyGenerator Safety Engine Safety Before servicing equipmentFuel Safety Towing Safety Never use fuel as a cleaning agent From fuel vapors or if fuel is spilled on a hot engineElectrical Safety Grounding SafetyPower Cord/Cable Safety Device. All installations should beBattery Safety Environmental SafetySpecifications Cummins QSL9-G3Dimensions DimensionsInstallation Typical Generator Grounding ApplicationOutdoor Installation Indoor InstallationMounting Generator GroundingGeneral Information Major Components Item noGenerator Control Panel Pilot Lamp Indicates the system is runningOwing from the U,V, and W Output Terminal Lugs to the load Air Filter Alarm When the air fi lter Engine Operating PanelPage Terminal legs O and Ground are considered bonded grounds Output Terminal Panel FamiliarizationOutput Terminal Familiarization VAC Gfci Receptacles 240V Twist-Lock Auxiliary ReceptaclesConnecting Loads Over Current RelayLoad Application Single Phase LoadThree Phase Load Generator Outputs Generator Output VoltagesVoltage Change-Over Board Maximum AmpsHOW to Read the AC Ammeter and AC Voltage Gauges Generator OUTPUTS/GAUGE ReadingAC Ammeter Gauge Reading AC Voltmeter Gauge ReadingOutput Terminal Panel Connections Uvwo Terminal Output Voltages3Ø-240V Uvwo Terminal Output Voltages 1Ø-240V Uvwo Terminal Output Voltages1Ø-277V Uvwo Terminal Output Voltages 3Ø-480V Uvwo Terminal Output Voltages1Ø-480V Uvwo Terminal Output Voltages INSPECTION/SETUP Circuit BreakersLubrication OIL Fuel CheckRefueling Procedure Only use #2 diesel fuel when refuelingCleaning the Radiator AIR Cleaner FAN Belt TensionCoolant ANTIFREEZE/SUMMER COOLANT/ Water Operation in Freezing WeatherBattery Battery Cable InstallationWiring AlternatorGenerator START-UP Procedure Manual Place the engine speed switch in the LOW down positionBefore Starting Starting ManualFrequency Meter Generator START-UP Procedure Auto Mode Starting Auto ModeBefore connecting this generator to any Place the engine speed switch in the High positionGenerator SHUT-DOWN Procedures Normal Shutdown ProcedureEmergency Shutdown Procedure Never stop the engine suddenly except in an emergencyAir Cleaner with Dust Indicator MaintenanceGeneral Inspection AIR Cleaner AIR Removal Fuel AdditionFuel Tank Inspection Radiator Cleaning Check OIL LevelReplacing Oil Filter Flushing OUT Radiator and Replacing CoolantBattery Charger and Jacket Water Heater Power Connections Coupler Type of hitch used on the trailer for towing Trailer MaintenanceTrailer Maintenance Brake Adjustment BrakesHydraulic Surge Brakes ActuatorSuspension TIRES/WHEELS/LUG NutsTire Wear/Inflation Lug Nut Torque Requirements Never use an pneumatic air gun to tighten wheel lug nutsTrailer Wiring Diagram Trailer/Towing Vehicle Wiring DiagramGenerator Wiring Diagram Generator Wiring DiagramEngine Wiring Diagram Engine Wiring DiagramPage Troubleshooting Generator Troubleshooting Engine Controller Clean/repair radiator grillAdjust governor actuator Adjust governor controllerTroubleshooting Diagnostic Lamp Method of OperationPage Sample Parts List Explanation of Code in Remarks ColumnSuggested Spare Parts To 3 unitsGenerator Assy 0601842402 06018232820018205020 4A# 0040005000Generator Assy C3154400003 0017106015C3164600103 0010310030Control BOX Assy M5213000002 06018096590027106015 0601807513Control BOX Assy 38 a 0601810244 06018316700601831205 0601830746Engine and Radiator Assy C2923200204 06020152443288497 0602046638Engine and Radiator Assy 0603306395 06020210700269200800 0602010220Engine Operating Panel Assy C2351101903 00171060200207006000 0602101000Output Terminal Assy C2231700403 C02775000040801830904 0039320000Battery Assy 0165614551 145G51C9109100604 3972250004Muffler Assy C2331100002 0019210025M5333000003 0602325066Fuel Tank Assy C2363000303 08101050040810105400 0264100525Enclosure Assy C2413003202 C3414100104C2414100004 C2414600304Enclosure Assy Door ROD Enclosure Assy Gutter Rubber Seals Assy Seal Rubber Nameplate and Decals Assy Control BOX Group Nameplate and Decals Assy Battery Group Terms and Conditions of Sale Parts Freight PolicyPage HERE’S HOW to GET Help

DCA300SSC specifications

The Multiquip DCA300SSC is a durable and powerful skid-mounted diesel generator designed for a range of applications, including construction sites, events, and emergency backup power. With a robust operational capacity of 300 kilowatts, this generator stands out for its reliability and efficiency in providing continuous power.

One of the key features of the DCA300SSC is its commercial-grade engine. The generator is equipped with a reliable and efficient diesel engine that ensures optimal performance under various operating conditions. This engine is designed for durability and longevity, minimizing the need for frequent maintenance. The generator's high fuel efficiency reduces operational costs, making it an economical choice for businesses and contractors.

Another notable characteristic of the DCA300SSC is its advanced sound attenuation technology. This design feature significantly lowers noise levels during operation, which is essential for applications in populated areas or sensitive environments. The generator is housed in a weather-resistant enclosure that protects it from environmental factors, ensuring consistent performance regardless of weather conditions.

In terms of power management, the DCA300SSC is equipped with a sophisticated digital control panel that allows users to monitor and manage the generator’s performance effectively. The control panel displays vital information, such as voltage, frequency, and run-time hours, facilitating easy operation and troubleshooting. This technology also integrates automatic voltage regulation, enhancing the generator's stability and safety during operation.

Safety is a priority in the design of the DCA300SSC. It is built with multiple safety features, including low oil pressure shutdown, high coolant temperature shutdown, and over-speed protection. These measures provide peace of mind to users by reducing the risk of equipment failure and ensuring safe operation.

The compact design and skid-mounted configuration of the DCA300SSC allow for easy transport and installation, making it a versatile solution for a variety of industries. Additionally, the generator can be configured for different voltage outputs, further increasing its adaptability for specific applications.

In summary, the Multiquip DCA300SSC is a powerful and versatile generator known for its reliability, efficiency, and advanced features. With its durable construction, advanced sound attenuation, user-friendly control panel, and robust safety features, it meets the demands of both commercial and industrial applications with ease. Whether for temporary power supply or backup generation, the DCA300SSC is a suitable choice for professionals seeking dependable energy solutions.