BATTERY ASSY.

NO.

PART NO.

PART NAME

QTY.

REMARKS

1

0165614551

BATTERY

2

145G51

2

C9109100604

BATTERY SHEET

2

 

3

3972250004

BATTERY BAND

1

 

4

0805002904

BATTERY BOLT

2

 

5

0037808000

WING NUT

2

 

6

0040008000

WASHER, LOCK

2

 

7

0041608000

WASHER, FLAT

2

 

8

C2346600404

BATTERY CABLE

1

 

9

C2346600304

BATTERY CABLE

1

 

10

C2347600704

BATTERY CABLE

1

 

11

C2346600504

BATTERY CABLE

1

 

12

C2346200004

EARTH CABLE

2

 

13

0347010030

HEX HEAD BOLT

4

 

14

0208110000

HEX NUT

4

 

15

0845040414

TERMINAL CAP (+)

2

 

16

0845041304

TERMINAL CAP (-)

2

 

17

0017116030

HEX HEAD BOLT

1

 

18

0040516000

TOOTHED WASHER

1

 

19

0017112025

HEX HEAD BOLT

1

 

20

0040512000

TOOTHED WASHER

1

 

DCA300SSC GENERATOR • OPERATION AND PARTS MANUAL — REV. #0 (06/25/09) — PAGE 73

Image 73
Contents This Manual Must Accompany the Equipment AT ALL Times Model DCA300SSCProposition 65 Warning Nhtsa Reporting Safety DefectsDCA300SSC Table of ContentsOrdering parts has never been easier Parts Ordering ProceduresSafety Messages Safety InformationGenerator Safety General Safety Always know the location of the nearest Before servicing equipment Engine SafetyTowing Safety Fuel Safety Never use fuel as a cleaning agent From fuel vapors or if fuel is spilled on a hot engineGrounding Safety Electrical SafetyPower Cord/Cable Safety Device. All installations should beEnvironmental Safety Battery SafetyCummins QSL9-G3 SpecificationsDimensions DimensionsTypical Generator Grounding Application InstallationIndoor Installation Outdoor InstallationMounting Generator GroundingGeneral Information Item no Major ComponentsPilot Lamp Indicates the system is running Generator Control PanelOwing from the U,V, and W Output Terminal Lugs to the load Engine Operating Panel Air Filter Alarm When the air fi lterPage Output Terminal Familiarization Output Terminal Panel FamiliarizationTerminal legs O and Ground are considered bonded grounds 240V Twist-Lock Auxiliary Receptacles VAC Gfci ReceptaclesOver Current Relay Connecting LoadsThree Phase Load Single Phase LoadLoad Application Generator Output Voltages Generator OutputsVoltage Change-Over Board Maximum AmpsGenerator OUTPUTS/GAUGE Reading HOW to Read the AC Ammeter and AC Voltage GaugesAC Ammeter Gauge Reading AC Voltmeter Gauge ReadingUvwo Terminal Output Voltages Output Terminal Panel Connections3Ø-240V Uvwo Terminal Output Voltages 1Ø-240V Uvwo Terminal Output Voltages1Ø-480V Uvwo Terminal Output Voltages 3Ø-480V Uvwo Terminal Output Voltages1Ø-277V Uvwo Terminal Output Voltages Circuit Breakers INSPECTION/SETUPLubrication OIL Fuel CheckOnly use #2 diesel fuel when refueling Refueling ProcedureAIR Cleaner FAN Belt Tension Cleaning the RadiatorCoolant ANTIFREEZE/SUMMER COOLANT/ Water Operation in Freezing WeatherBattery Cable Installation BatteryWiring AlternatorPlace the engine speed switch in the LOW down position Generator START-UP Procedure ManualBefore Starting Starting ManualFrequency Meter Starting Auto Mode Generator START-UP Procedure Auto ModeBefore connecting this generator to any Place the engine speed switch in the High positionNormal Shutdown Procedure Generator SHUT-DOWN ProceduresEmergency Shutdown Procedure Never stop the engine suddenly except in an emergencyGeneral Inspection AIR Cleaner MaintenanceAir Cleaner with Dust Indicator Fuel Tank Inspection Fuel AdditionAIR Removal Check OIL Level Radiator CleaningReplacing Oil Filter Flushing OUT Radiator and Replacing CoolantBattery Charger and Jacket Water Heater Power Connections Trailer Maintenance Trailer MaintenanceCoupler Type of hitch used on the trailer for towing Brakes Brake AdjustmentHydraulic Surge Brakes ActuatorTire Wear/Inflation TIRES/WHEELS/LUG NutsSuspension Never use an pneumatic air gun to tighten wheel lug nuts Lug Nut Torque RequirementsTrailer/Towing Vehicle Wiring Diagram Trailer Wiring DiagramGenerator Wiring Diagram Generator Wiring DiagramEngine Wiring Diagram Engine Wiring DiagramPage Troubleshooting Generator Clean/repair radiator grill Troubleshooting Engine ControllerAdjust governor actuator Adjust governor controllerMethod of Operation Troubleshooting Diagnostic LampPage Explanation of Code in Remarks Column Sample Parts ListTo 3 units Suggested Spare PartsGenerator Assy 0601823282 06018424020018205020 4A# 0040005000Generator Assy 0017106015 C3154400003C3164600103 0010310030Control BOX Assy 0601809659 M52130000020027106015 0601807513Control BOX Assy 0601831670 38 a 06018102440601831205 0601830746Engine and Radiator Assy 0602015244 C29232002043288497 0602046638Engine and Radiator Assy 0602021070 06033063950269200800 0602010220Engine Operating Panel Assy 0017106020 C23511019030207006000 0602101000Output Terminal Assy C0277500004 C22317004030801830904 0039320000Battery Assy 145G51 0165614551C9109100604 3972250004Muffler Assy 0019210025 C2331100002M5333000003 0602325066Fuel Tank Assy 0810105004 C23630003030810105400 0264100525Enclosure Assy C3414100104 C2413003202C2414100004 C2414600304Enclosure Assy Door ROD Enclosure Assy Gutter Rubber Seals Assy Seal Rubber Nameplate and Decals Assy Control BOX Group Nameplate and Decals Assy Battery Group Freight Policy Terms and Conditions of Sale PartsPage HERE’S HOW to GET Help

DCA300SSC specifications

The Multiquip DCA300SSC is a durable and powerful skid-mounted diesel generator designed for a range of applications, including construction sites, events, and emergency backup power. With a robust operational capacity of 300 kilowatts, this generator stands out for its reliability and efficiency in providing continuous power.

One of the key features of the DCA300SSC is its commercial-grade engine. The generator is equipped with a reliable and efficient diesel engine that ensures optimal performance under various operating conditions. This engine is designed for durability and longevity, minimizing the need for frequent maintenance. The generator's high fuel efficiency reduces operational costs, making it an economical choice for businesses and contractors.

Another notable characteristic of the DCA300SSC is its advanced sound attenuation technology. This design feature significantly lowers noise levels during operation, which is essential for applications in populated areas or sensitive environments. The generator is housed in a weather-resistant enclosure that protects it from environmental factors, ensuring consistent performance regardless of weather conditions.

In terms of power management, the DCA300SSC is equipped with a sophisticated digital control panel that allows users to monitor and manage the generator’s performance effectively. The control panel displays vital information, such as voltage, frequency, and run-time hours, facilitating easy operation and troubleshooting. This technology also integrates automatic voltage regulation, enhancing the generator's stability and safety during operation.

Safety is a priority in the design of the DCA300SSC. It is built with multiple safety features, including low oil pressure shutdown, high coolant temperature shutdown, and over-speed protection. These measures provide peace of mind to users by reducing the risk of equipment failure and ensuring safe operation.

The compact design and skid-mounted configuration of the DCA300SSC allow for easy transport and installation, making it a versatile solution for a variety of industries. Additionally, the generator can be configured for different voltage outputs, further increasing its adaptability for specific applications.

In summary, the Multiquip DCA300SSC is a powerful and versatile generator known for its reliability, efficiency, and advanced features. With its durable construction, advanced sound attenuation, user-friendly control panel, and robust safety features, it meets the demands of both commercial and industrial applications with ease. Whether for temporary power supply or backup generation, the DCA300SSC is a suitable choice for professionals seeking dependable energy solutions.