Multiquip DCA300SSC C3154400003, 0017106015, C3164600103, 0010310030, 17A 0042510000, C2163700004

Page 59

GENERATOR ASSY. (CONTINUED)

NO.

PART NO.

PART NAME

QTY.

REMARKS

14

C3154400003

SUCTION COVER

1

 

15

0017106015

HEX HEAD BOLT

8

 

16

C3164600103

COUPLING ADAPTER

1

 

17

0010310030

HEX HEAD BOLT

12

 

17A

0042510000

WASHER, LOCK

12

 

18

C2163700004

SPACER, BEARING

1

 

19

0070506208

BEARING, 6208ZZ

1

 

20

0010312040

HEX HEAD BOLT

16

 

20A

0042512000

WASHER, LOCK

16

 

21

C3132300014

COVER, FAN

1

 

22

0010106030

HEX HEAD BOLT

1

 

22A

0041206000

WASHER, FLAT

1

 

22B

0600815000

NUT

1

 

23

0605000012

RUBBER SUSPENSION

2

 

24

0030020000

HEX NUT

4

 

24A

0040020000

WASHER, LOCK

4

 

DCA300SSC GENERATOR • OPERATION AND PARTS MANUAL — REV. #0 (06/25/09) — PAGE 59

Image 59
Contents This Manual Must Accompany the Equipment AT ALL Times Model DCA300SSCProposition 65 Warning Nhtsa Reporting Safety DefectsDCA300SSC Table of ContentsOrdering parts has never been easier Parts Ordering ProceduresSafety Messages Safety Information Always know the location of the nearest General SafetyGenerator Safety Before servicing equipment Engine SafetyFrom fuel vapors or if fuel is spilled on a hot engine Fuel SafetyTowing Safety  Never use fuel as a cleaning agentDevice. All installations should be Electrical SafetyGrounding Safety Power Cord/Cable SafetyEnvironmental Safety Battery SafetyCummins QSL9-G3 SpecificationsDimensions DimensionsTypical Generator Grounding Application InstallationGenerator Grounding Outdoor InstallationIndoor Installation MountingGeneral Information Item no Major ComponentsPilot Lamp Indicates the system is running Generator Control PanelOwing from the U,V, and W Output Terminal Lugs to the load Engine Operating Panel Air Filter Alarm When the air fi lterPage Terminal legs O and Ground are considered bonded grounds Output Terminal Panel FamiliarizationOutput Terminal Familiarization 240V Twist-Lock Auxiliary Receptacles VAC Gfci ReceptaclesOver Current Relay Connecting LoadsLoad Application Single Phase LoadThree Phase Load Maximum Amps Generator OutputsGenerator Output Voltages Voltage Change-Over BoardAC Voltmeter Gauge Reading HOW to Read the AC Ammeter and AC Voltage GaugesGenerator OUTPUTS/GAUGE Reading AC Ammeter Gauge Reading1Ø-240V Uvwo Terminal Output Voltages Output Terminal Panel ConnectionsUvwo Terminal Output Voltages 3Ø-240V Uvwo Terminal Output Voltages1Ø-277V Uvwo Terminal Output Voltages 3Ø-480V Uvwo Terminal Output Voltages1Ø-480V Uvwo Terminal Output Voltages Fuel Check INSPECTION/SETUPCircuit Breakers Lubrication OILOnly use #2 diesel fuel when refueling Refueling ProcedureOperation in Freezing Weather Cleaning the RadiatorAIR Cleaner FAN Belt Tension Coolant ANTIFREEZE/SUMMER COOLANT/ WaterAlternator BatteryBattery Cable Installation WiringStarting Manual Generator START-UP Procedure ManualPlace the engine speed switch in the LOW down position Before StartingFrequency Meter Place the engine speed switch in the High position Generator START-UP Procedure Auto ModeStarting Auto Mode Before connecting this generator to anyNever stop the engine suddenly except in an emergency Generator SHUT-DOWN ProceduresNormal Shutdown Procedure Emergency Shutdown ProcedureAir Cleaner with Dust Indicator MaintenanceGeneral Inspection AIR Cleaner AIR Removal Fuel AdditionFuel Tank Inspection Flushing OUT Radiator and Replacing Coolant Radiator CleaningCheck OIL Level Replacing Oil FilterBattery Charger and Jacket Water Heater Power Connections Coupler Type of hitch used on the trailer for towing Trailer MaintenanceTrailer Maintenance Actuator Brake AdjustmentBrakes Hydraulic Surge BrakesSuspension TIRES/WHEELS/LUG NutsTire Wear/Inflation Never use an pneumatic air gun to tighten wheel lug nuts Lug Nut Torque RequirementsTrailer/Towing Vehicle Wiring Diagram Trailer Wiring DiagramGenerator Wiring Diagram Generator Wiring DiagramEngine Wiring Diagram Engine Wiring DiagramPage Troubleshooting Generator Adjust governor controller Troubleshooting Engine ControllerClean/repair radiator grill Adjust governor actuatorMethod of Operation Troubleshooting Diagnostic LampPage Explanation of Code in Remarks Column Sample Parts ListTo 3 units Suggested Spare PartsGenerator Assy 4A# 0040005000 06018424020601823282 0018205020Generator Assy 0010310030 C31544000030017106015 C3164600103Control BOX Assy 0601807513 M52130000020601809659 0027106015Control BOX Assy 0601830746 38 a 06018102440601831670 0601831205Engine and Radiator Assy 0602046638 C29232002040602015244 3288497Engine and Radiator Assy 0602010220 06033063950602021070 0269200800Engine Operating Panel Assy 0602101000 C23511019030017106020 0207006000Output Terminal Assy 0039320000 C2231700403C0277500004 0801830904Battery Assy 3972250004 0165614551145G51 C9109100604Muffler Assy 0602325066 C23311000020019210025 M5333000003Fuel Tank Assy 0264100525 C23630003030810105004 0810105400Enclosure Assy C2414600304 C2413003202C3414100104 C2414100004Enclosure Assy Door ROD Enclosure Assy Gutter Rubber Seals Assy Seal Rubber Nameplate and Decals Assy Control BOX Group Nameplate and Decals Assy Battery Group Freight Policy Terms and Conditions of Sale PartsPage HERE’S HOW to GET Help

DCA300SSC specifications

The Multiquip DCA300SSC is a durable and powerful skid-mounted diesel generator designed for a range of applications, including construction sites, events, and emergency backup power. With a robust operational capacity of 300 kilowatts, this generator stands out for its reliability and efficiency in providing continuous power.

One of the key features of the DCA300SSC is its commercial-grade engine. The generator is equipped with a reliable and efficient diesel engine that ensures optimal performance under various operating conditions. This engine is designed for durability and longevity, minimizing the need for frequent maintenance. The generator's high fuel efficiency reduces operational costs, making it an economical choice for businesses and contractors.

Another notable characteristic of the DCA300SSC is its advanced sound attenuation technology. This design feature significantly lowers noise levels during operation, which is essential for applications in populated areas or sensitive environments. The generator is housed in a weather-resistant enclosure that protects it from environmental factors, ensuring consistent performance regardless of weather conditions.

In terms of power management, the DCA300SSC is equipped with a sophisticated digital control panel that allows users to monitor and manage the generator’s performance effectively. The control panel displays vital information, such as voltage, frequency, and run-time hours, facilitating easy operation and troubleshooting. This technology also integrates automatic voltage regulation, enhancing the generator's stability and safety during operation.

Safety is a priority in the design of the DCA300SSC. It is built with multiple safety features, including low oil pressure shutdown, high coolant temperature shutdown, and over-speed protection. These measures provide peace of mind to users by reducing the risk of equipment failure and ensuring safe operation.

The compact design and skid-mounted configuration of the DCA300SSC allow for easy transport and installation, making it a versatile solution for a variety of industries. Additionally, the generator can be configured for different voltage outputs, further increasing its adaptability for specific applications.

In summary, the Multiquip DCA300SSC is a powerful and versatile generator known for its reliability, efficiency, and advanced features. With its durable construction, advanced sound attenuation, user-friendly control panel, and robust safety features, it meets the demands of both commercial and industrial applications with ease. Whether for temporary power supply or backup generation, the DCA300SSC is a suitable choice for professionals seeking dependable energy solutions.