Multiquip DCA125USI manual Refueling Procedure, Only use #2 diesel fuel when refueling

Page 31

INSPECTION/SETUP

Refueling Procedure:

WARNING

Diesel fuel and its vapors are dangerous to your health and the surrounding environment. Avoid skin contact and/or inhaling fumes.

1.Level Tanks — Make sure fuel cells are level with the ground. Failure to do so will cause fuel to spill from the tank before reaching full capacity (Figure 30).

CAUTION

ALWAYS place trailer on fi rm level ground before refueling to prevent spilling and maximize the amount of fuel that can be pumped into the tank.

Figure 30. Only Fill on Level Ground

NOTICE

ONLY use #2 diesel fuel when refueling.

2.Open cabinet doors on the “right side” of the generator (from generator control panel position). Remove fuel cap and fi ll tank (Figure 31).

Figure 31. Fueling the Generator

3.NEVER overfill fuel tank — It is important to read the fuel gauge when fi lling trailer fuel tank. DO NOT wait for fuel to rise in fi ller neck (Figure 32).

Figure 32. Full Fuel Tank

CAUTION

DO NOT OVERFILL fuel system. Leave room for fuel expansion. Fuel expands when heated (Figure 33).

Figure 33. Fuel Expansion

DCA125USI 60 HZ GEN. • OPERATION AND PARTS MANUAL — REV. #1 (03/25/11) — PAGE 31

Image 31
Contents This Manual Must Accompany the Equipment AT ALL Times Model DCA125USIProposition 65 Warning Administrator Reporting Safety DefectsNhtsa DCA125USI 60 Hz Generator Table of ContentsOrdering parts has never been easier Parts Ordering ProceduresSafety Messages Safety InformationGenerator Safety General Safety Always know the location of the nearest Before servicing equipment Engine SafetyFrom fuel vapors or if fuel is spilled on a hot engine Fuel SafetyTowing Safety  Never use fuel as a cleaning agentDevice. All installations should be Electrical Safety Never use gas piping as an electrical ground Environmental Safety Battery SafetyDCA125USI SpecificationsDimensions DimensionsTypical Generator Grounding Application InstallationGenerator Grounding Outdoor InstallationIndoor Installation MountingGeneral Information Major Components Owing from the U,V, and W Output Terminal Lugs to the load Generator Control PanelPage Engine Operating Panel Engine Operating PanelModule Fuel Gauge Indicates amount of diesel fuel availableOutput Terminal Familiarization Output Terminal Panel FamiliarizationTerminal legs O and Ground are considered bonded grounds VAC Gfci Receptacles Removing the Plastic Face Plate Hard Wire Hookup PanelTwist Lock Dual Voltage 120/240 VAC Receptacles Over Current Relay Connecting LoadsThree Phase Load Single Phase LoadLoad Application Generator Output Voltages Generator OutputsGenerator OUTPUTS/GAUGE Reading HOW to Read the AC Ammeter and AC Voltage GaugesAC Voltmeter Gauge Reading 3Ø-208V/1Ø-120V Uvwo Terminal Output Voltages Output Terminal Panel ConnectionsUvwo Terminal Output Voltages 3Ø-240/139 Uvwo Terminal Output Voltages1Ø-240/120V Uvwo Terminal Output Voltages 3Ø-480/277V Uvwo Terminal Output VoltagesFuel Check INSPECTION/SETUPCircuit Breakers Lubrication OILOnly use #2 diesel fuel when refueling Refueling ProcedureOperation in Freezing Weather Cleaning the RadiatorAIR Cleaner FAN Belt Tension Coolant ANTIFREEZE/SUMMER COOLANT/ WaterAlternator BatteryBattery Cable Installation WiringStarting Manual Generator START-UP ProcedureBefore Starting StartingPre-Heat Lamp To shutdown the generator, use the following procedure Generator SHUT-DOWN ProceduresNormal Shutdown Procedure Emergency Shutdown ProcedureGeneral Inspection AIR Cleaner MaintenanceAir Cleaner with Dust Indicator Fuel Tank Inspection Fuel AdditionAIR Removal Flushing OUT Radiator and Replacing Coolant Radiator CleaningCheck OIL Level Replacing Oil FilterBattery Charger & Jacket Water Heater Power Connections Trailer Maintenance Trailer MaintenanceCoupler Type of hitch used on the trailer for towing Through 8 and as listed below Brake AdjustmentBrakes Hydraulic Surge BrakesTire Wear/Infl ation TIRES/WHEELS/LUG NutsSuspension Start all wheel lug nuts by hand Lug Nut Torque RequirementsNever use an pneumatic air gun to tighten wheel lug nuts Trailer/Towing Vehicle Wiring Diagram Trailer Wiring DiagramGenerator Wiring Diagram Generator Wiring DiagramEngine Wiring Diagram Engine Wiring DiagramController Wiring Diagram Controller Wiring DiagramTroubleshooting Generator Method of Operation Troubleshooting Diagnostic LampPage Explanation of Code in Remarks Column Sample Parts ListXxxxx only Not Used on To 3 units Suggested Spare PartsGenerator Assy FAN Part Name QTY. RemarksIncludes Items W/# Field AssyControl BOX Assy Switch Bracket Push Button SwitchDiagonastic Switch Selector SwitchControl BOX Assy SWITCH, Panel Light Switch CoverAlarm Lamp Water Temperature GaugeEngine and Radiator Assy BAND, AIR Cleaner AIR CleanerINDICATOR, AIR Cleaner Bracket AIR CleanerEngine and Radiator Assy Hose Joint ConnectorAIR Duct Hose Blow by HoseEngine and Radiator Assy BRACKET, FAN Shroud BRACKET, Inter CoolerCooler Hose FAN ShroudOutput Terminal Assy Output Window Terminal BoardOutput Terminal Bolt Terminal CoverBattery Assy Battery Bolt SET BatteryBattery Sheet Battery BandMuffler Assy Gasket MufflerBolt SET Fuel Tank Assy Connect Hose Fuel TankFuel Tank CAP Fuel Sender UnitEnclosure ASSY. Part Enclosure ASSY. PART1 Enclosure ASSY. Part COVER, Radiator CAP Back PlateDuct Over COVER, Front FrameEnclosure ASSY. Part Rear Frame Enclosure ASSY. Part Washer Seal RubberManual PAK Rubber Seals Assy Part Name Nameplate and Decals Assy Output Terminal Group Battery GroupControl BOX Group Engine & Radiator GroupNameplate and Decals Assy Enclosure Group Fuel Tank GroupFreight Policy Terms and Conditions of Sale PartsPage HERE’S HOW to GET Help
Related manuals
Manual 4 pages 56.26 Kb

DCA125USI specifications

The Multiquip DCA125USI is a high-performance portable diesel generator renowned for its reliability, efficiency, and robust construction, making it an ideal choice for construction sites, events, and remote locations requiring continuous power. Engineered for durability, this generator features a solid and compact design that allows seamless transport while providing ample power to meet demanding applications.

One of the standout features of the DCA125USI is its powerful 125 kVA output, capable of supplying electricity to a wide range of equipment simultaneously. With a fuel-efficient Tier 4 compliant engine, this generator not only delivers high performance but also addresses environmental concerns through reduced emissions. Operating at low noise levels, the DCA125USI ensures a quieter work environment, making it suitable for urban areas and noise-sensitive locations.

In terms of technology, the DCA125USI is equipped with a state-of-the-art digital control panel that offers advanced monitoring capabilities, allowing users to easily track the generator's performance, fuel consumption, and overall health. This user-friendly interface simplifies operation and enhances the overall experience for users, whether they are seasoned professionals or first-time operators. Additionally, the generator is fitted with automatic voltage regulation (AVR), which provides stable power output, protecting connected equipment from voltage fluctuations.

Safety is a priority with the Multiquip DCA125USI, as evidenced by its comprehensive set of protection features, including low oil pressure shutdown, high-temperature shutdown, and overload protection. These safety mechanisms ensure the longevity of the engine and the generator's components while safeguarding connected equipment against potential damage.

Another notable characteristic is its large fuel tank, which allows for extended run times, reducing the need for frequent refueling. This feature is particularly beneficial in situations where access to fuel is limited or where continuous operation is critical.

In conclusion, the Multiquip DCA125USI is a versatile and dependable portable diesel generator, catering to a wide variety of applications. Its combination of high output, advanced technology, and robust safety features make it an excellent investment for contractors, event organizers, and anyone in need of reliable power in challenging environments. With this generator, users can have peace of mind knowing they have a powerful energy solution at their disposal.