Multiquip DCA125USI Trailer Maintenance, Coupler Type of hitch used on the trailer for towing

Page 41

TRAILER MAINTENANCE

TRAILER MAINTENANCE

This section is intended to provide the user with generic trailer service and maintenance information. The service and maintenance guidelines referenced in this section refer to a wide range of trailers.

Remember periodic inspection of the trailer will ensure safe towing of the generator and will prevent personal injury and damage to the equipment.

The definitions below describe some of the major components of a typical trailer that would be used with generator.

1.Fuel Cell — Provides an adequate amount of fuel for the equipment in use. Fuel cells must be empty when transporting equipment.

2.Braking System — System employed in stopping the trailer. Typical braking systems are electric, surge, hydraulic, hydraulic-surge and air.

3.GVWR — Gross Vehicle Weight Rating (GVWR) is the maximum number of pounds the trailer can carry, including the fuel cell (empty).

4.Frame Length — Measurement is from the ball hitch to the rear bumper (refl ector).

5.Frame Width — Measurement is from fender to fender

6.Jack Stand — Trailer support device with maximum pound requirement from the tongue of the trailer.

7.Coupler — Type of hitch used on the trailer for towing.

8.Tire Size — Indicates the diameter of the tire in inches (10,12,14, etc.), and the width in millimeters (175,185,205, etc.). The tire diameter must match the diameter of the tire rim.

9.Tire Ply — The tire ply (layers) number is rated in letters; 2-ply,4-ply,6-ply, etc.

10.Wheel Hub — The wheel hub is connected to the trailer’s axle.

11.Tire Rim — Tires mounted on a tire rim. The tire rim must match the size of the tire.

12.Lug Nuts — Used to secure the wheel to the wheel hub. Always use a torque wrench to tighten down the lug nuts. See Table 18 and Figure 63 for lug nut tightening and sequence.

13.Axle — Indicates the maximum weight the axle can support in pounds, and the diameter of the axle expressed in inches. Please note that some trailers have a double axle. This will be shown as 2-6000 lbs., meaning two axles with a total weight capacity of 6000 pounds.

14.Suspension — Protects the trailer chassis from shocks transmitted through the wheels. Types of suspension used are leaf, Q-fl ex, and air ride.

15.Electrical — Electrical connectors (looms) are provided with the trailer so the brake lights and turn signals can be connected to the towing vehicle.

16.Application — Indicates which units can be employed on a particular trailer.

DCA125USI 60 HZ GEN. • OPERATION AND PARTS MANUAL — REV. #1 (03/25/11) — PAGE 41

Image 41
Contents This Manual Must Accompany the Equipment AT ALL Times Model DCA125USIProposition 65 Warning Nhtsa Reporting Safety DefectsAdministrator DCA125USI 60 Hz Generator Table of ContentsOrdering parts has never been easier Parts Ordering ProceduresSafety Messages Safety Information Always know the location of the nearest General SafetyGenerator Safety Before servicing equipment Engine SafetyTowing Safety Fuel Safety Never use fuel as a cleaning agent From fuel vapors or if fuel is spilled on a hot engine Never use gas piping as an electrical ground Electrical SafetyDevice. All installations should be Environmental Safety Battery SafetyDCA125USI SpecificationsDimensions DimensionsTypical Generator Grounding Application InstallationIndoor Installation Outdoor InstallationMounting Generator GroundingGeneral Information Major Components Owing from the U,V, and W Output Terminal Lugs to the load Generator Control PanelPage Engine Operating Panel Engine Operating PanelModule Fuel Gauge Indicates amount of diesel fuel availableTerminal legs O and Ground are considered bonded grounds Output Terminal Panel FamiliarizationOutput Terminal Familiarization Twist Lock Dual Voltage 120/240 VAC Receptacles Removing the Plastic Face Plate Hard Wire Hookup PanelVAC Gfci Receptacles Over Current Relay Connecting LoadsLoad Application Single Phase LoadThree Phase Load Generator Output Voltages Generator OutputsAC Voltmeter Gauge Reading HOW to Read the AC Ammeter and AC Voltage GaugesGenerator OUTPUTS/GAUGE Reading Uvwo Terminal Output Voltages Output Terminal Panel Connections3Ø-240/139 Uvwo Terminal Output Voltages 3Ø-208V/1Ø-120V Uvwo Terminal Output Voltages1Ø-240/120V Uvwo Terminal Output Voltages 3Ø-480/277V Uvwo Terminal Output VoltagesCircuit Breakers INSPECTION/SETUPLubrication OIL Fuel CheckOnly use #2 diesel fuel when refueling Refueling ProcedureAIR Cleaner FAN Belt Tension Cleaning the RadiatorCoolant ANTIFREEZE/SUMMER COOLANT/ Water Operation in Freezing WeatherBattery Cable Installation BatteryWiring AlternatorBefore Starting Generator START-UP ProcedureStarting Starting ManualPre-Heat Lamp Normal Shutdown Procedure Generator SHUT-DOWN ProceduresEmergency Shutdown Procedure To shutdown the generator, use the following procedureAir Cleaner with Dust Indicator MaintenanceGeneral Inspection AIR Cleaner AIR Removal Fuel AdditionFuel Tank Inspection Check OIL Level Radiator CleaningReplacing Oil Filter Flushing OUT Radiator and Replacing CoolantBattery Charger & Jacket Water Heater Power Connections Coupler Type of hitch used on the trailer for towing Trailer MaintenanceTrailer Maintenance Brakes Brake AdjustmentHydraulic Surge Brakes Through 8 and as listed belowSuspension TIRES/WHEELS/LUG NutsTire Wear/Infl ation Never use an pneumatic air gun to tighten wheel lug nuts Lug Nut Torque RequirementsStart all wheel lug nuts by hand Trailer/Towing Vehicle Wiring Diagram Trailer Wiring DiagramGenerator Wiring Diagram Generator Wiring DiagramEngine Wiring Diagram Engine Wiring DiagramController Wiring Diagram Controller Wiring DiagramTroubleshooting Generator Method of Operation Troubleshooting Diagnostic LampPage Xxxxx only Not Used on Sample Parts ListExplanation of Code in Remarks Column To 3 units Suggested Spare PartsGenerator Assy Includes Items W/# Part Name QTY. RemarksField Assy FANControl BOX Assy Diagonastic Switch Push Button SwitchSelector Switch Switch BracketControl BOX Assy Alarm Lamp Switch CoverWater Temperature Gauge SWITCH, Panel LightEngine and Radiator Assy INDICATOR, AIR Cleaner AIR CleanerBracket AIR Cleaner BAND, AIR CleanerEngine and Radiator Assy AIR Duct Hose ConnectorBlow by Hose Hose JointEngine and Radiator Assy Cooler Hose BRACKET, Inter CoolerFAN Shroud BRACKET, FAN ShroudOutput Terminal Assy Output Terminal Bolt Terminal BoardTerminal Cover Output WindowBattery Assy Battery Sheet BatteryBattery Band Battery Bolt SETMuffler Assy Bolt SET MufflerGasket Fuel Tank Assy Fuel Tank CAP Fuel TankFuel Sender Unit Connect HoseEnclosure ASSY. Part Enclosure ASSY. PART1 Enclosure ASSY. Part Duct Back PlateOver COVER, Front Frame COVER, Radiator CAPEnclosure ASSY. Part Rear Frame Enclosure ASSY. Part Manual PAK Seal RubberWasher Rubber Seals Assy Part Name Nameplate and Decals Assy Control BOX Group Battery GroupEngine & Radiator Group Output Terminal GroupNameplate and Decals Assy Enclosure Group Fuel Tank GroupFreight Policy Terms and Conditions of Sale PartsPage HERE’S HOW to GET Help
Related manuals
Manual 4 pages 56.26 Kb

DCA125USI specifications

The Multiquip DCA125USI is a high-performance portable diesel generator renowned for its reliability, efficiency, and robust construction, making it an ideal choice for construction sites, events, and remote locations requiring continuous power. Engineered for durability, this generator features a solid and compact design that allows seamless transport while providing ample power to meet demanding applications.

One of the standout features of the DCA125USI is its powerful 125 kVA output, capable of supplying electricity to a wide range of equipment simultaneously. With a fuel-efficient Tier 4 compliant engine, this generator not only delivers high performance but also addresses environmental concerns through reduced emissions. Operating at low noise levels, the DCA125USI ensures a quieter work environment, making it suitable for urban areas and noise-sensitive locations.

In terms of technology, the DCA125USI is equipped with a state-of-the-art digital control panel that offers advanced monitoring capabilities, allowing users to easily track the generator's performance, fuel consumption, and overall health. This user-friendly interface simplifies operation and enhances the overall experience for users, whether they are seasoned professionals or first-time operators. Additionally, the generator is fitted with automatic voltage regulation (AVR), which provides stable power output, protecting connected equipment from voltage fluctuations.

Safety is a priority with the Multiquip DCA125USI, as evidenced by its comprehensive set of protection features, including low oil pressure shutdown, high-temperature shutdown, and overload protection. These safety mechanisms ensure the longevity of the engine and the generator's components while safeguarding connected equipment against potential damage.

Another notable characteristic is its large fuel tank, which allows for extended run times, reducing the need for frequent refueling. This feature is particularly beneficial in situations where access to fuel is limited or where continuous operation is critical.

In conclusion, the Multiquip DCA125USI is a versatile and dependable portable diesel generator, catering to a wide variety of applications. Its combination of high output, advanced technology, and robust safety features make it an excellent investment for contractors, event organizers, and anyone in need of reliable power in challenging environments. With this generator, users can have peace of mind knowing they have a powerful energy solution at their disposal.