Multiquip dca-70usj Air Removal, Check Oil Level, Replacing Oil Filter, Replacing Fuel Filter

Page 42

Air Removal

If air enters the fuel injection system of a diesel engine, starting becomes impossible. After running out of fuel, or after disassembling the fuel system, bleed the system according to the following procedure. See the John Deere Engine Manual for details.

Check Oil Level

Check the crankcase oil level prior to each use, or when the fuel tank is filled. Insufficient oil may cause severe damage to the engine. Make sure the generator is level.The oil level must be between the two notches on the dipstick as shown in Figure 33.

Replacing Oil Filter

Remove the old oil filter.

Apply a film of oil to the gasket on the new oil filter.

Install the new oil filter.

After the oil cartridge has been replaced, the engine oil will drop slightly. Run the engine for a while and check for leaks before adding more oil if needed. Clean excessive oil from engine.

Replacing Fuel Filter

Replace the fuel filter cartridge with new one every 500 hours or so.

Loosen the drain plug at the lower top of the fuel filter. Drain the fuel in the fuel body together with the mixed water. DO NOT spill the fuel during disassembly.

Vent any air.

DCA-70USJ — MAINTENANCE

Flushing Out Radiator and Replacing Coolant

Open both cocks located at the crankcase side and at the lower part of the radiator and drain coolant. Open the radiator cap while draining. Remove the overflow tank and drain.

Check hoses for softening and kinks. Check clamps for signs of leakage.

Flush the radiator by running clean tap water through radiator until signs of rust and dirt are removed. DO NOT clean radiator core with any objects, such as a screwdriver.

Tighten both cocks and replace the overflow tank.

Replace with coolant as recommended by the engine manufaturer.

Close radiator cap tightly.

WARNING - BURN HAZARDS

Allow engine to cool when flushing out radiator. Flushing the radiator while hot could cause serious burns from water or steam.

Generator Storage

For longe term storage of the generator the following is recommended:

Fill the fuel tank completely. Treat with a fuel stabilizer if necessary.

Completely drain the oil from the crankcase and refill if necessary with fresh oil.

Clean the entire generator, internal and external.

Cover the generating set and store in a clean, dry place.

Disconnect the battery.

Make sure engine coolant is at proper level.

If generator is mounted on a trailer, jack trailer up and place on blocks so tires do not touch the ground or block and completely remove the tires.

PAGE 42 — DCA-70USJ — OPERATION AND PARTS MANUAL — REV. #0 (09/16/04)

Image 42
Contents Parts List NO. M2870400114 Model DCA-70USJ2 DCA-70USJ Operation and Parts Manual REV. #0 09/16/04 Heres HOW to GET Help Wilmington Ave Carson, CATable of Contents Parts Ordering Procedures When ordering parts Please supply the following informationDCA-70USJ Specifications Generator SpecificationsDCA-70USJ Dimensions TOP, Side and Front DCA85USJ Safety Message Alert Symbols You can be injured if you do not follow directionsDCA85USJ Safety Message Alert Symbols This generator, other property, orGeneral Safety DCA-70USJ Rules for Safe OperationElectrical Safety Generator GroundingMaintenance Safety Battery SafetyDCA-70USJ Rules for Safe Operation Towing &Transporting Safety EmergenciesDCA-70USJ Generator Decals Generator DecalsDCA-70USJ Generator Decals Generator Decals Cont inuedDCA-70USJ Installation Typical Generator Grounding ApplicationIndoor Installation DCA-70USJ InstallationOutdoor Installation When connecting the generatorDCA-70USJ General Information DCA-70USJ Major Components Major Components20 DCA-70USJ Operation and Parts Manual REV. #0 09/16/04 Adjustment of the generator’s output voltage Ammeter phase-selector switchBe switched off OnlyDCA-70USJ Engine Operating Panel DCA-70USJ Engine Operating Panel DCA-70USJ Output Terminal Panel Familiarization Output Terminal Familiarization120VAC Gfci Receptacles F.C.I. ReceptacleConnecting Loads Blower FanDCA-70USJ Load Application Single Phase LoadThree Phase Load Motors and motor-drivenGenerator Amperage Voltage Selector SwitchDCA-70USJ Generator Outputs Generator OutputVoltagesHow to Read the OutputTerminal Gauges DCA-70USJ Gauge ReadingReading Amperage Uvwo Terminal Output Voltages Three-Phase PositionDCA-70USJ Outputterminal Panel Connections 3Ø 240/139 Output Terminal Lug Voltages3Ø 480/277 Output Terminal Lug Voltages 1Ø 240V/120V Output Terminal Lug VoltagesLubrication Oil DCA-70USJ PRE-SETUPCircuit Breakers Fuel CheckRefueling Procedure RefuelingOperation FreezingWeather Cleaning the RadiatorAir Cleaner Fan BeltTension Vol % Freezing PointWiring BatteryBattery Cable Installation AlternatorDirect exhaust away from nearby personnel Before StartingEngines exhaust contains harmful emissions Close all engine enclosure doors FigureStarting Manual Position to start the engine FigureOil Pressure Gauge Starting Auto Mode Place the Mpec Control Switch in the Auto positionDCA-70USJ Generator SHUT-DOWN Procedure Shutdown ProcedureEmergency Shutdown Procedure DCA-70USJ Maintenance Replacing Oil Filter Air RemovalCheck Oil Level Replacing Fuel FilterDCA-70USJ Maintenance To ensure adequate startingDCA-70USJ -TRAILER Maintenance Trailer MaintenanceBrakes DCA-70USJ -TRAILER MaintenanceBrake Adjustment Check the wheel and drum for free rotationTires/Wheels/Lug Nuts TireWear/InflationSuspension Lug NutTorque Requirements Start all wheel lug nuts by handDCA-70USJ -TRAILERWIRING Diagram Trailer/Towing Vehicle Wiring DiagramDCA-70USJ Generatorwiring Diagram DCA-70USJ Enginewiring Diagram Engine Wiring DiagramDCA-70USJ -TROUBLESHOOTING Generator DCA-70USJ -TROUBLESHOOTING Engine Controller Engine Controller Troubleshooting MpecDCA-70USJ Operation and Parts Manual REV. #0 09/16/04 Explanation of Code in Remarks Column Items Found In the Items Number ColumnIf more than one of the same Part number on this Suggested Spare Parts list DCA-70USJ Suggested Spare PartsDCA-70USJ Generator Assy 0012810035 B51101006028101070033 8101611004DCA-70USJ Control BOX Assy 0601808824 M22130007020330000180 002100508060 DCA-70USJ Operation and Parts Manual REV. #0 09/16/04 DCA-70USJ Control BOX Assy DCA-70USJ Engine & Radiator Assy RE504836 M29232000140602041292 060204259564 DCA-70USJ Operation and Parts Manual REV. #0 09/16/04 0603300285 06020225610603306590 0605511395DCA-70USJ Outputterminal Assy M2233100004 M2230700113M2233000004 0039312000DCA-70USJ Battery Assy M9310500014 0602220187627MFD M9103000304DCA-70USJ Muffler Assy M2333000703 M23301008030017112030 M2333200204DCA-70USJ Fueltank Assy 0605501073 M23630009020605505070 0605516090DCA-70USJ Enclosure #1 Assy 0603306797 M2413001502M2363300203 M242300091276 DCA-70USJ Operation and Parts Manual REV. #0 09/16/04 28B 0040020000 001012005028A 0030020000 28C 0041220000DCA-70USJ Enclosure #2 Assy Enclosure #2 AssyM3443000914 M3443000812M3493303203 M3493303304DCA-70USJ Enclosure #3 Assy 0229201240 02292008700229201130 0228900660DCA-70USJ Name Plate Assy M2550000304 M1550000204M1550000703 M2550000603Terms and Conditions of Sale Parts FreightpolicyDCA-70USJ Operation and Parts Manual REV. #0 09/16/04 Your Local Dealer is