Multiquip dca-70usj operation manual DCA-70USJ Maintenance

Page 41

DCA-70USJ — MAINTENANCE

TABLE 13. INSPECTION/MAINTENANCE

10 Hrs

250 Hrs

500 Hrs

1000 Hrs

DAILY

 

 

 

 

 

 

 

 

 

 

 

 

Check Engine Fluid Levels

X

 

 

 

 

 

 

 

 

 

 

Check Air Cleaner

X

 

 

 

 

 

 

 

 

 

 

Check Battery Acid Level

X

 

 

 

 

 

 

 

 

 

 

Check Fan Belt Condition

X

 

 

 

 

 

 

 

 

 

 

Check for Leaks

X

 

 

 

 

 

 

 

 

 

 

Check for Loosening of Parts

X

 

 

 

 

 

 

 

 

 

 

Replace Engine Oil and Filter * 1

 

X

 

 

 

 

 

 

 

 

ENGINE

Clean Air Filter

 

X

 

 

 

 

 

 

 

 

 

Check Fuel Filter/Water Seperator Bowl

X

 

 

 

 

 

 

 

 

 

 

Clean Unit, Inside and Outside

 

X

 

 

 

 

 

 

 

 

 

Change Fuel Filter

 

 

X

 

 

 

 

 

 

 

 

Clean Radiator and Check Coolant Protection Level*2

 

 

X

 

 

Replace Air Filter Element * 3

 

 

X

 

 

 

 

 

 

 

 

Check all Hoses and Clamps * 4

 

 

 

X

 

 

 

 

 

 

 

Clean Inside of Fuel Tank

 

 

 

X

 

 

 

 

 

 

GENERATOR

Measure Insulation Resistance Over 3M ohms

 

X

 

 

 

 

 

 

 

Check Rotor Rear Support Bearing

 

 

X

 

 

 

 

 

 

 

 

 

 

 

*1 Replace engine oil anf filter at 100 hours, first time only.

*2 Add "Supplemental Coolant Addatives (SCA'S)" to recharge the engine coolant.

*3 Replace primary air filter element when restriction indicator shows a vaccum of 625 mm (25 in. H20).

*4 If blowby hose needs to be replaced, ensure that the slope of the bloby hose is at least a 1/2 inch per foot, with no sags or dips that could collect moisture and/or oil.

General Inspection

Prior to each use, the generator should be cleaned and inspected for deficiencies. Check for loose, missing or damaged nuts, bolts or other fasteners. Also check for fuel, oil, and coolant leaks.

Engine Side (Refer to the Engine Instruction Manual)

Air Cleaner

Every 250 hours: Remove air cleaner element and clean the heavy duty paper element with light spray of compressed air. Replace the air cleaner as needed.

Air Cleaner with Dust Indicator

This indicator is attached to the air cleaner. When the air cleaner element is clogged, air intake restriction becomes greater and the dust indicator signal shows RED meaning the element needs changing or service. After changing the air element, press the dust indicator button to reset the indicator.

Service Daily

If the engine is operating in very dusty or dry grass conditions, a clogged air cleaner will result.This can lead to

aloss of power, excessive carbon buildup in the combustion chamber and high fuel consumption. Change air cleaner more frequently if these conditions exists.

Fuel Addition

Add diesel fuel (the grade may vary according to season and locations).

Removing Water from the Fuel Tank

After prolonged use, water and other impurities accumulate in the bottom of the tank. Occasionally inspect the fuel tank for water contamination and drain the contents if required.

During cold weather, the more empty volume inside the tank, the easier it is for water to condense. This can be reduced by keeping the tank full with diesel fuel.

DCA-70USJ — OPERATION AND PARTS MANUAL — REV. #0 (09/16/04) — PAGE 41

Image 41
Contents Model DCA-70USJ Parts List NO. M28704001142 DCA-70USJ Operation and Parts Manual REV. #0 09/16/04 Wilmington Ave Carson, CA Heres HOW to GET HelpTable of Contents When ordering parts Please supply the following information Parts Ordering ProceduresGenerator Specifications DCA-70USJ SpecificationsDCA-70USJ Dimensions TOP, Side and Front You can be injured if you do not follow directions DCA85USJ Safety Message Alert SymbolsThis generator, other property, or DCA85USJ Safety Message Alert SymbolsDCA-70USJ Rules for Safe Operation General SafetyGenerator Grounding Electrical SafetyDCA-70USJ Rules for Safe Operation Maintenance SafetyBattery Safety Emergencies Towing &Transporting SafetyGenerator Decals DCA-70USJ Generator DecalsGenerator Decals Cont inued DCA-70USJ Generator DecalsTypical Generator Grounding Application DCA-70USJ InstallationOutdoor Installation DCA-70USJ InstallationIndoor Installation When connecting the generatorDCA-70USJ General Information Major Components DCA-70USJ Major Components20 DCA-70USJ Operation and Parts Manual REV. #0 09/16/04 Be switched off Ammeter phase-selector switchAdjustment of the generator’s output voltage OnlyDCA-70USJ Engine Operating Panel DCA-70USJ Engine Operating Panel Output Terminal Familiarization DCA-70USJ Output Terminal Panel FamiliarizationF.C.I. Receptacle 120VAC Gfci ReceptaclesBlower Fan Connecting LoadsThree Phase Load Single Phase LoadDCA-70USJ Load Application Motors and motor-drivenDCA-70USJ Generator Outputs Voltage Selector SwitchGenerator Amperage Generator OutputVoltagesReading Amperage How to Read the OutputTerminal GaugesDCA-70USJ Gauge Reading DCA-70USJ Outputterminal Panel Connections Three-Phase PositionUvwo Terminal Output Voltages 3Ø 240/139 Output Terminal Lug Voltages1Ø 240V/120V Output Terminal Lug Voltages 3Ø 480/277 Output Terminal Lug VoltagesCircuit Breakers DCA-70USJ PRE-SETUPLubrication Oil Fuel CheckRefueling Refueling ProcedureAir Cleaner Fan BeltTension Cleaning the RadiatorOperation FreezingWeather Vol % Freezing PointBattery Cable Installation BatteryWiring AlternatorEngines exhaust contains harmful emissions Before StartingDirect exhaust away from nearby personnel Close all engine enclosure doors FigurePosition to start the engine Figure Starting ManualOil Pressure Gauge Place the Mpec Control Switch in the Auto position Starting Auto ModeEmergency Shutdown Procedure DCA-70USJ Generator SHUT-DOWN ProcedureShutdown Procedure DCA-70USJ Maintenance Check Oil Level Air RemovalReplacing Oil Filter Replacing Fuel FilterTo ensure adequate starting DCA-70USJ MaintenanceTrailer Maintenance DCA-70USJ -TRAILER MaintenanceBrake Adjustment DCA-70USJ -TRAILER MaintenanceBrakes Check the wheel and drum for free rotationSuspension Tires/Wheels/Lug NutsTireWear/Inflation Start all wheel lug nuts by hand Lug NutTorque RequirementsTrailer/Towing Vehicle Wiring Diagram DCA-70USJ -TRAILERWIRING DiagramDCA-70USJ Generatorwiring Diagram Engine Wiring Diagram DCA-70USJ Enginewiring DiagramDCA-70USJ -TROUBLESHOOTING Generator Engine Controller Troubleshooting Mpec DCA-70USJ -TROUBLESHOOTING Engine ControllerDCA-70USJ Operation and Parts Manual REV. #0 09/16/04 If more than one of the same Explanation of Code in Remarks ColumnItems Found In the Items Number Column DCA-70USJ Suggested Spare Parts Part number on this Suggested Spare Parts listDCA-70USJ Generator Assy 8101070033 B51101006020012810035 8101611004DCA-70USJ Control BOX Assy 0330000180 M22130007020601808824 002100508060 DCA-70USJ Operation and Parts Manual REV. #0 09/16/04 DCA-70USJ Control BOX Assy DCA-70USJ Engine & Radiator Assy 0602041292 M2923200014RE504836 060204259564 DCA-70USJ Operation and Parts Manual REV. #0 09/16/04 0603306590 06020225610603300285 0605511395DCA-70USJ Outputterminal Assy M2233000004 M2230700113M2233100004 0039312000DCA-70USJ Battery Assy 627MFD 0602220187M9310500014 M9103000304DCA-70USJ Muffler Assy 0017112030 M2330100803M2333000703 M2333200204DCA-70USJ Fueltank Assy 0605505070 M23630009020605501073 0605516090DCA-70USJ Enclosure #1 Assy M2363300203 M24130015020603306797 M242300091276 DCA-70USJ Operation and Parts Manual REV. #0 09/16/04 28A 0030020000 001012005028B 0040020000 28C 0041220000Enclosure #2 Assy DCA-70USJ Enclosure #2 AssyM3493303203 M3443000812M3443000914 M3493303304DCA-70USJ Enclosure #3 Assy 0229201130 02292008700229201240 0228900660DCA-70USJ Name Plate Assy M1550000703 M1550000204M2550000304 M2550000603Freightpolicy Terms and Conditions of Sale PartsDCA-70USJ Operation and Parts Manual REV. #0 09/16/04 Your Local Dealer is