Multiquip SGW-250SS Cleaning the Radiator, Fan Belt Tension, Operation in Freezing Weather

Page 25

BLW-400SSWPRE-SETUP

CAUTION :

When adding coolant or antifreeze to the radiator, do not remove the radiator cap until the unit has completely cooled.

Day-to-day addition of coolant or antifreeze is done from the reserve tank. See Table 9 for engine, radiator and reserve tank coolant capacities. Make sure the coolant level in the reserve tank is always between the "H" and the "L" markings.

Table 9. Coolant Capacity

Engine and Radiator

1.1 Gal. (4.16L)

 

 

Reserve Tank

0.2 Gal. (0.75L)

 

 

Cleaning the Radiator

The radiator may overheat if the fins become overloaded with dust or debris. Periodically clean the radiator fins with compressed air.

Fan Belt Tension

A slack fan belt may contribute to overheating, or to insufficient charging of the battery. Inspect and adjust it in accordance with the Kubota Engine Operator's Manual.

The fan belt tension is proper if the fan belt (Figure 5) bends 7 to 9 mm (0.28- to 0.35 in.) when depressed with the thumb as shown in Figure 13 below.

Operation in Freezing Weather

When operating in freezing weather, be certain that the proper amount of antifreeze has been added. See Table 10 for antifreeze operating temperatures.

Table 10. Anti-Freeze Operating Temperatures

Vol %

Freezing Point

Boiling Point

 

 

 

 

Anti-Freeze

°C

°F

°C

°F

 

 

 

 

 

 

40

-24

-12

106

222

 

 

 

 

 

50

-37

-34

108

226

 

 

 

 

 

NOTE

When the antifreeze is mixed with water, the antifreeze mixing ratio must be less than 50%.

Figure 13. Fan Belt Tension

CAUTION :

Never place hands near the belts or fan while the welder/AC generator is running.

Air Cleaner

Periodic cleaning/replacement is necessary. Inspect it in accordance with the Kobota Engine Operator's Manual.

Battery

This unit is of negative ground. DO NOT connect in reverse. Always maintain battery fluid level between the specified marks. Battery life will be shortened, if the fluid level is not properly maintained. Add only distilled water when replenishment is necessary.

The battery is sufficiently charged if the specific gravity of the battery fluid is 1.28 (at 68° F). If the specific gravity should fall to 1.245 or lower, it indicates that the battery is dead and needs to be recharged or replaced.

Check to see whether the battery cables are loose. Poor contact may result in poor starting or malfunctions, always keep the terminals firmly tightened. Coating the terminals with a thin film of grease will help to inhibit corrosion.

SGW-250SS DC WELDER/AC GENERATOR — PARTS & OPERATION MANUAL — REV. #2 (08/08/01) — PAGE 25

Image 25
Contents MQ Power Whisperweldtm Page Heres HOW to GET Help Table of Contents Parts Ordering Procedures Earn Extra Discounts when You order by FAXRules for Safe Operation General SafetyRules for Safe Operation Operation and Safety Decals Operation and Safety Decals SGW-250SS Specifications Generator Oil Pressure Warning AlarmControl Panel Welder Protection SystemSGW-250SS Dimensions SGW-250SS DimensionsExplanation of Chart SGW-250SS -TRAILER-SAFETY GuidelinesTRLR-10W SGW-250SS TRAILER-SPECIFICATIONSModel Coupler Tires Wheels Axle Hubs Suspension Electrical Tire Wear/Inflation Tires/Wheels/Lug NutsSuspension Torque Ft.-Lbs SGW-250SS -TRAILER Safety GuidelinesLug Nut Torque Requirements SGW-250SS -TRAILER-WIRING Diagram SGW-250SS -TOWING Towing Safety PrecautionsSGW-250SS Controls and Indicators SGW-250SS Controls and Indicators Outdoor Installation SGW-250SS InstallationSelecting Optimum Welding Cable SGW-250SS PRE-SETUP Battery Air CleanerLubrication Oil FuelFan Belt Tension Cleaning the RadiatorOperation in Freezing Weather Main Circuit Breaker 2-Pole Idle Control SwitchGfci Protection Breaker Single-Pole Fuel GaugeSGW-250SS Load Application Single Phase LoadWelding Cables and Polarities SGW-250SS -WELDER Operating InstructionsSGW-250SS -WELDER Operating Instructions Auxiliary AC PowerDuty Cycle Welding and Auxiliary OutputsBefore Starting SGW-250SS Engine Operating InstructionsStarting ShutdownSGW-250SS Maintenance Inspection / Maintenance Welder/Generator Storage SGW-250SS Preparation for Long -TERM StorageSGW-250SS -ENGINE/GENERATORWIRING Diagram SGW-250SS -TROUBLESHOOTING Welder SGW-250SS -TROUBLESHOOTING Engine Engine Troubleshooting Part SGW-250SS -TROUBLESHOOTING EngineEngine Troubleshooting Part Items Found In the Items Number Column Explanation of Code in Remarks ColumnQty Description SGW-250SS Suggested Spare PartsGenerator Assy SGW-250SS Generator AssyFAN Includes Items WSET Bolt Rotor END BracketControl Panel Assy SGW-250SS Control Panel AssySeal Machine ScrewRV24YN20SB2KO RA25YN20SB2KOJSGW-250SS Control Panel Assy Knob Selector Switches Symbol SealElectric Parts Assy SGW-250SS Electric Parts AssyAC Reactor Wire StopperARM Solenoid Spring PINBattery Assy SGW-250SS Battery AssyBattery Bolt Battery BandTerminal CAP RED Terminal CAPTail Pipe Assy SGW-250SS Tail Pipe AssyPipe Band Outlet PipeFuel Tank Assy SGW-250SS Fuel Tank AssyRing Drain PlugFuel Hose Hose BandEnclosure Assy SGW-250SS Enclosure AssyEdge Cover BaseBase Cover Engine BaseName Plate and Decals Assy SGW-250SS Name Plate and Decals AssyDCS01 Replaces D25200040BWith Model and S/N See Decal Illustrations on page 8Cylinder Head Assy Honda GX610VXD Engine Cylinder Head AssyCLIP, Valve Guide GUIDE, EX. Valve OSCOVER, Head COVER, Head FillerCylinder Barrel Assy Honda GX610VXD Engine Cylinder Barrel AssyCLAMP, Wire COLLAR, Filter SettingSwitch ASSY., OIL Level COVER, BreatherCrankcase Cover Assy Honda GX610VXD Engine Crankcase Cover AssyBOLT, Sealing GASKET, Case CoverSPRING, Relief Valve COVER, OIL FilterCrankshaft Assy Honda GX610VXD Engine Crankshaft Assy13310ZJ0880 Piston Assy Honda GX610VXD Engine Piston AssyBearing F Connecting ROD Bearing E, Connecting RODBearing G Connecting ROD BOLT, Connecting RODCamshaft Assy Honda GX610VXD Engine Camshaft AssyHOLDER, Governor Weight SPRING, Weight ReturnPLATE, Governor Weight Holder PIN, Governor Weight HolderFAN Cover Assy Honda GX610VXD Engine FAN Cover AssyHonda GX610VXD Engine -FAN Cover Assy Carburetor Assy Honda GX610VXD Engine Carburetor AssyTUBE, Breather GASKET, AIR CleanerCLIP, Breather Tube Gasket SETAIR Cleaner Assy Honda GX610VXD Engine AIR Cleaner AssyGROMMET, AIR Cleaner COVER, AIR CleanerHOSE, AIR Cleaner TUBE, AIR Cleaner ConnMuffler Assy Honda GX610VXD Engine Muffler AssyBand Assy Pipe COMP., EX. HIGH-LFuel Pump Assy Honda GX610VXD Engine Fuel Pump Assy Flywheel Assy FAN, Cooling Honda GX610VXD Engine Flywheel AssyFlywheel Comp NUT, Flange 20MMIgnition Coil Assy Honda GX610VXD Engine Ignition Coil AssyCoil ASSY., R. Ignition GROMMET, Ignition WireCoil ASSY., L. Ignition GROMMET, ToolStarter Motor Assy Honda GX610VXD Engine Starter Motor AssyMotor ASSY., Starter Cover A, Magnetic SwitchNUT, Washer 6MM Control Assy Honda GX610VXD Engine Control AssySPRING, Return HOLDER, WireROD, Governor SPRING, GovernorEffective July 1 Page Denyo MANUFACTURING, CO., USA

SGW-250SS specifications

The Multiquip SGW-250SS is an innovative and robust generator designed for a wide range of applications, from construction sites to outdoor events. This generator stands out due to its combination of reliability, efficiency, and portability, making it a top choice for professionals and enthusiasts alike.

One of the main features of the SGW-250SS is its powerful 25 kW output. This high output capacity ensures that it can handle multiple tools and equipment simultaneously, making it ideal for construction or industrial applications. The generator is equipped with a durable engine that delivers impressive performance even under heavy loads, ensuring that users can rely on it to meet their power needs without interruption.

In addition to its powerful output, the SGW-250SS boasts a range of advanced technologies aimed at maximizing performance and minimizing operating costs. The generator features an advanced digital control panel that simplifies operation and monitoring. This panel provides essential information such as voltage output, frequency, and operating hours, allowing users to keep track of performance effortlessly.

Another notable characteristic of the SGW-250SS is its robust construction. Designed to withstand harsh environments, this generator features a corrosion-resistant frame and heavy-duty components that enhance its longevity. The generator also offers excellent noise reduction capabilities, making it a suitable option for use in noise-sensitive areas.

Portability is another key aspect of the Multiquip SGW-250SS, as it is designed with mobility in mind. The generator comes equipped with rugged wheels and a foldable handle, allowing for easy transport across various terrains. This feature is particularly beneficial for contractors who need to move the generator frequently between job sites.

Safety features are also integral to the design of the SGW-250SS. It includes low oil shutdown and circuit breaker protection, which help to prevent damage and ensure safe operation. These safety measures are essential in maintaining the generator's reliability and protecting both the equipment and the users.

In summary, the Multiquip SGW-250SS combines power, portability, and safety in a reliable generator package. Its advanced technologies, robust construction, and user-friendly features make it an excellent choice for various professional and recreational applications. Whether for construction, outdoor events, or emergency backup, the SGW-250SS is engineered to deliver performance and peace of mind.