Multiquip operation manual SGW-250SS -TRAILER-SAFETY Guidelines, Explanation of Chart

Page 13

SGW-250SS —TRAILER-SAFETY GUIDELINES

CAUTION:

ALWAYS make sure the trailer is in good operating condition. Check the tires for proper inflation and wear. Also check the wheel lug nuts for proper tightness.

Explanation of Chart:

This section is intended to provide the user with trailer ser- vice and maintenance information. The service and main- tenance guidelines referenced in this section apply a wide range of trailers. Remember periodic inspection of the trailer will ensure safe towing of the equipment and will prevent damage to the equipment and personal injury.

It is the purpose of this section to cover the major mainte- nance components of the trailer. The following trailer com- ponents will be discussed in this section:

„Brakes

„Tires

„Lug Nut Torquing

„Suspension

„Electrical

„Brake Troubleshooting Tables

Use the following definitions with reading Table 2.

1.Fuel Cell - Provides an adequate amount of fuel for the equipment in use. Fuel cells must be empty when transporting equipment.

2.Braking System - System employed in stopping the trailer. Typical braking systems are electric, surge, hy- draulic, hydraulic-surge and air.

3.GVWR- Gross Vehicle Weight Rating (GVWR), is the maximum number of pounds the trailer can carry, in- cluding the fuel cell (empty).

4.Frame Length - This measurement is from the ball hitch to the rear bumper (reflector).

5.Frame Width - This measurement is from fender to fender.

6.Jack Stand - Trailer support device with maximum pound requirement from the tongue of the trailer.

7.Coupler - Type of hitch used on the trailer for towing.

8.Tire Size - Indicates the diameter of the tire in inches (10,12,14, etc.), and the width in millimeters (175,185,205, etc.). The tire diameter must match the diameter of the tire rim.

9.Tire Ply - The tire ply (layers) number is rated in letters; 2-ply,4-ply,6-ply, etc.

10.Wheel Hub - The wheel hub is connected to the trailer’s axle.

11.Tire Rim - Tires mounted on a tire rim. The tire rim must match the size of the tire.

12.Lug Nuts - Used to secure the wheel to the wheel hub. Always use a torque wrench to tighten down the lug nuts. See Table 4 and Figure 5 or lug nut tightening and sequence.

13.Axle - Indicates the maximum weight the axle can sup- port in pounds, and the diameter of the axle expressed in inches (see Table 3). Please not that some trailers have a double axle. This will be shown as 2-6000 lbs., meaning two axles with a total weight capacity of 6000 pounds.

14.Suspension - Protects the trailer chassis from shocks transmitted through the wheels. Types of suspension used are leaf, Q-flex, and air ride.

15.Electrical - Electrical connectors (looms) are provided with the trailer so the brake lights and turn signals can be connected to the towing vehicle.

16.Application - Indicates which units can be employed on a particular trailer.

SGW-250SS DC WELDER/AC GENERATOR — PARTS & OPERATION MANUAL — REV. #2 (08/08/01) — PAGE 13

Image 13
Contents MQ Power Whisperweldtm Page Heres HOW to GET Help Table of Contents Parts Ordering Procedures Earn Extra Discounts when You order by FAXRules for Safe Operation General SafetyRules for Safe Operation Operation and Safety Decals Operation and Safety Decals SGW-250SS Specifications Generator Oil Pressure Warning AlarmControl Panel Welder Protection SystemSGW-250SS Dimensions SGW-250SS DimensionsExplanation of Chart SGW-250SS -TRAILER-SAFETY GuidelinesTRLR-10W SGW-250SS TRAILER-SPECIFICATIONSModel Coupler Tires Wheels Axle Hubs Suspension Electrical Tire Wear/Inflation Tires/Wheels/Lug NutsSuspension Torque Ft.-Lbs SGW-250SS -TRAILER Safety GuidelinesLug Nut Torque Requirements SGW-250SS -TRAILER-WIRING Diagram SGW-250SS -TOWING Towing Safety PrecautionsSGW-250SS Controls and Indicators SGW-250SS Controls and Indicators Outdoor Installation SGW-250SS InstallationSelecting Optimum Welding Cable SGW-250SS PRE-SETUP Battery Air CleanerLubrication Oil FuelFan Belt Tension Cleaning the RadiatorOperation in Freezing Weather Main Circuit Breaker 2-Pole Idle Control SwitchGfci Protection Breaker Single-Pole Fuel GaugeSGW-250SS Load Application Single Phase LoadWelding Cables and Polarities SGW-250SS -WELDER Operating InstructionsSGW-250SS -WELDER Operating Instructions Auxiliary AC PowerDuty Cycle Welding and Auxiliary OutputsBefore Starting SGW-250SS Engine Operating InstructionsStarting ShutdownSGW-250SS Maintenance Inspection / Maintenance Welder/Generator Storage SGW-250SS Preparation for Long -TERM StorageSGW-250SS -ENGINE/GENERATORWIRING Diagram SGW-250SS -TROUBLESHOOTING Welder SGW-250SS -TROUBLESHOOTING Engine Engine Troubleshooting Part SGW-250SS -TROUBLESHOOTING EngineEngine Troubleshooting Part Items Found In the Items Number Column Explanation of Code in Remarks ColumnQty Description SGW-250SS Suggested Spare PartsGenerator Assy SGW-250SS Generator AssyFAN Includes Items WSET Bolt Rotor END BracketControl Panel Assy SGW-250SS Control Panel AssySeal Machine ScrewRV24YN20SB2KO RA25YN20SB2KOJSGW-250SS Control Panel Assy Knob Selector Switches Symbol SealElectric Parts Assy SGW-250SS Electric Parts AssyAC Reactor Wire StopperARM Solenoid Spring PINBattery Assy SGW-250SS Battery AssyBattery Bolt Battery BandTerminal CAP RED Terminal CAPTail Pipe Assy SGW-250SS Tail Pipe AssyPipe Band Outlet PipeFuel Tank Assy SGW-250SS Fuel Tank AssyRing Drain PlugFuel Hose Hose BandEnclosure Assy SGW-250SS Enclosure AssyEdge Cover BaseBase Cover Engine BaseName Plate and Decals Assy SGW-250SS Name Plate and Decals AssyDCS01 Replaces D25200040BWith Model and S/N See Decal Illustrations on page 8Cylinder Head Assy Honda GX610VXD Engine Cylinder Head AssyCLIP, Valve Guide GUIDE, EX. Valve OSCOVER, Head COVER, Head FillerCylinder Barrel Assy Honda GX610VXD Engine Cylinder Barrel AssyCLAMP, Wire COLLAR, Filter SettingSwitch ASSY., OIL Level COVER, BreatherCrankcase Cover Assy Honda GX610VXD Engine Crankcase Cover AssyBOLT, Sealing GASKET, Case CoverSPRING, Relief Valve COVER, OIL FilterCrankshaft Assy Honda GX610VXD Engine Crankshaft Assy13310ZJ0880 Piston Assy Honda GX610VXD Engine Piston AssyBearing F Connecting ROD Bearing E, Connecting RODBearing G Connecting ROD BOLT, Connecting RODCamshaft Assy Honda GX610VXD Engine Camshaft AssyHOLDER, Governor Weight SPRING, Weight ReturnPLATE, Governor Weight Holder PIN, Governor Weight HolderFAN Cover Assy Honda GX610VXD Engine FAN Cover AssyHonda GX610VXD Engine -FAN Cover Assy Carburetor Assy Honda GX610VXD Engine Carburetor AssyTUBE, Breather GASKET, AIR CleanerCLIP, Breather Tube Gasket SETAIR Cleaner Assy Honda GX610VXD Engine AIR Cleaner AssyGROMMET, AIR Cleaner COVER, AIR CleanerHOSE, AIR Cleaner TUBE, AIR Cleaner ConnMuffler Assy Honda GX610VXD Engine Muffler AssyBand Assy Pipe COMP., EX. HIGH-LFuel Pump Assy Honda GX610VXD Engine Fuel Pump Assy Flywheel Assy FAN, Cooling Honda GX610VXD Engine Flywheel AssyFlywheel Comp NUT, Flange 20MMIgnition Coil Assy Honda GX610VXD Engine Ignition Coil AssyCoil ASSY., R. Ignition GROMMET, Ignition WireCoil ASSY., L. Ignition GROMMET, ToolStarter Motor Assy Honda GX610VXD Engine Starter Motor AssyMotor ASSY., Starter Cover A, Magnetic SwitchNUT, Washer 6MM Control Assy Honda GX610VXD Engine Control AssySPRING, Return HOLDER, WireROD, Governor SPRING, GovernorEffective July 1 Page Denyo MANUFACTURING, CO., USA

SGW-250SS specifications

The Multiquip SGW-250SS is an innovative and robust generator designed for a wide range of applications, from construction sites to outdoor events. This generator stands out due to its combination of reliability, efficiency, and portability, making it a top choice for professionals and enthusiasts alike.

One of the main features of the SGW-250SS is its powerful 25 kW output. This high output capacity ensures that it can handle multiple tools and equipment simultaneously, making it ideal for construction or industrial applications. The generator is equipped with a durable engine that delivers impressive performance even under heavy loads, ensuring that users can rely on it to meet their power needs without interruption.

In addition to its powerful output, the SGW-250SS boasts a range of advanced technologies aimed at maximizing performance and minimizing operating costs. The generator features an advanced digital control panel that simplifies operation and monitoring. This panel provides essential information such as voltage output, frequency, and operating hours, allowing users to keep track of performance effortlessly.

Another notable characteristic of the SGW-250SS is its robust construction. Designed to withstand harsh environments, this generator features a corrosion-resistant frame and heavy-duty components that enhance its longevity. The generator also offers excellent noise reduction capabilities, making it a suitable option for use in noise-sensitive areas.

Portability is another key aspect of the Multiquip SGW-250SS, as it is designed with mobility in mind. The generator comes equipped with rugged wheels and a foldable handle, allowing for easy transport across various terrains. This feature is particularly beneficial for contractors who need to move the generator frequently between job sites.

Safety features are also integral to the design of the SGW-250SS. It includes low oil shutdown and circuit breaker protection, which help to prevent damage and ensure safe operation. These safety measures are essential in maintaining the generator's reliability and protecting both the equipment and the users.

In summary, the Multiquip SGW-250SS combines power, portability, and safety in a reliable generator package. Its advanced technologies, robust construction, and user-friendly features make it an excellent choice for various professional and recreational applications. Whether for construction, outdoor events, or emergency backup, the SGW-250SS is engineered to deliver performance and peace of mind.