Multiquip operation manual DCA-100SSVU Generator Control Panel

Page 21

DCA-100SSVU — GENERATOR CONTROL PANEL

Figure 6. Generator Control Panel

The definitions below describe the controls and functions of the DCA-100SSVU Generator Control Panel (Figure 6).

1.Frequency Meter – Indicates the output frequency in hertz (Hz). Normally 60 Hz.

2.AC Ammeter – Indicates the amount of current the load is drawing from the generator per leg selected by the ammeter phase-selector switch.

3.AC Voltmeter – Indicates the output voltage present at the U,V, and W Output Terminal Lugs.

4.Voltage Regulator Control – Allows ±15% manual adjustment of the generator’s output voltage.

5.Ammeter Change-Over Switch – This switch allows the AC ammeter to indicate the current flowing to the load connected to any phase of the output terminals, or to be switched off. This switch does not effect the generator output in any fashion, it is for current reading only.

6.Voltmeter Change-Over Switch – This switch allows the AC voltmeter to indicate phase to phase voltage between any two phases of the output terminals or to be switched off.

7.Main Circuit Breaker – This three-pole, 250A main breaker is provided to protect the the U,V,andW Output Terminal Lugs from overload.

Located behind the generator control panel is the Generator Control Box. This box contains some of the necessary electronic components required to make the generator function.

The Control Box is equipped with the following major components:

Over-Current Relay

Voltage Rectifer (AVR)

Starter Relay

Current Transformer

Voltage Selector Switch

Three Phase Circuit Breaker

Remember the overcurrent

NOTErelay monitors the current flowing from the U,V, and W Output Terminal Lugs to the load.

In the event of a short circuit or over current condition, it will automatically trip the 250 amp main breaker.

To restore power to the Output Terminal Panel, press the reset button on the overcurrent relay and place the main circuit breaker in the closed position (ON).

DCA-100SSVU— OPERATION AND PARTS MANUAL — REV. #0 (11/05/07) — PAGE 21

Image 21
Contents Model DCA-100SSVU Parts List NO. M3870300704F2 DCA-100SSVU- Operation and Parts Manual REV. #0 11/05/07 Heres HOW to GET Help Table of Contents When ordering parts Please supply the following information Parts Ordering ProceduresDCA-100SSVU Specifications Dimensions DCA-100SSVU Dimensions TOP, Side and FrontHazard Symbols DCA-100SSVU Safety Message Alert SymbolsDCA-100SSVU Safety Message Alert Symbols DCA-100SSVU Rules for Safe Operation General SafetyElectrical Safety DCA-100SSVU Rules for Safe OperationGenerator Grounding Battery Safety Maintenance SafetyEmergencies Towing &Transporting SafetyGenerator Decals DCA-100SSVU Generator DecalsGenerator Decals Cont inued DCA-100SSVU Generator DecalsTypical Generator Grounding Application DCA-100SSVU InstallationOutdoor Installation DCA-100SSVU InstallationIndoor Installation MountingEngine Operating Panel GeneratorGenerator Control Panel Output Terminal PanelMajor Components DCA-100SSVU Major Components20 DCA-100SSVU- Operation and Parts Manual REV. #0 11/05/07 DCA-100SSVU Generator Control Panel DCA-100SSVU Engine Operating Panel DCA-100SSVU Engine Operating Panel Output Terminal Familiarization DCA-100SSVU Output Terminal Panel Familiarization100VAC Gfci Receptacles DCA-100SSVU Output Terminal Panel FamiliarizationOver Current Relay Connecting LoadsSingle Phase Load Three Phase LoadDCA-100SSVU Load Application Generator OutputVoltages Voltage Selector SwitchGenerator Amperage Gfci Receptacle Load CapabilityHow to Read the Output Terminal Gauges DCA-100SSVU Gauge ReadingReading Amperage DCA-100SSVU Output Terminal Panel Connections Three-Phase PositionUvwo Terminal Output Voltages 3Ø 240/139 Output Terminal Lug VoltagesDCA-100SSVU Output Terminal Panel Connections 3Ø 480/277 Output Terminal Lug Voltages1Ø 240V/120V Output Terminal Lug Voltages Circuit Breakers DCA-100SSVU SetupLubrication Oil Fuel CheckRefueling Refueling ProcedureAir Cleaner Fan Belt Tension Cleaning the RadiatorCoolant Antifreeze/Summer Coolant/Water Operation FreezingWeatherBattery Cable Installation BatteryWiring AlternatorBefore Starting DCA-100SSVU Generator START-UP Procedure ManualNo Load Coolant Temperature GaugeMpec Control Switch Auto Starting Auto ModeEmergency Shutdown Procedure Normal Shutdown ProcedureDCA-100SSVU Maintenance Air Removal Cleaning the Fuel StrainerCheck Oil Level Replacing Oil FilterBattery Charger JacketWater Heater Power Connections Trailer Maintenance DCA-100SSVU -TRAILER MaintenanceBrake Adjustment BrakesHydraulic Surge Brakes Tires/Wheels/Lug Nuts TireWear/InflationSuspension Lug Nut Torque Requirements DCA-100SSVU -TRAILER MaintenanceTrailer/Towing Vehicle Wiring Diagram DCA-100SSVU -TRAILERWIRING DiagramGenerator Wiring Diagram DCA-100SSVU Generatorwiring DiagramEngine Wiring Diagram DCA-100SSVU Enginewiring DiagramGenerator Troubleshooting DCA-100SSVU -TROUBLESHOOTING GeneratorEngine Controller Troubleshooting Mpec DCA-100SSVU -TROUBLESHOOTING Engine ControllerDCA-100SSVU Explanation of Code in Remarks Column Sample Parts ListDescription DCA-100SSVU Suggested Spare PartsGenerator Assy DCA-100SSVU Generator AssyFAN Field AssyCoupling Disk HEX Head BoltEngine Operating Panel Assy DCA-100SSVU- Engine Operating Panel AssyEngine Speed Switch SwitchWater Temperature Gauge SWITCH, Panel LightDCA-100SSVU- Control BOX ASSY. S/N 78000001~78000129 Circuit BREAKER, 3P 250A Switch BoardMachine Screw Relay UnitControl BOX ASSY. CONT. S/N 7800001~7800129 SET Screw Sensor TemperatureSnap Ring RELAY, DC12VControl BOX ASSY. S/N 7800130~AND Above DCA-100SSVU- Control BOX ASSY. S/N 78000130 and AboveAutomatic Voltage Reulator DCA-100SSVU- Control BOX ASSY. S/N 78000130 and AboveControl BOX ASSY. CONT. S/N 7800130~AND Above PTF08A RELAY, LY-2D DC12VPYCA1 LY2DUS12VDCEngine and Radiator Assy DCA-100SSVU- Engine and Radiator AssyDCA-100SSVU- Engine and Radiator Assy Output Terminal Assy DCA-100SSVU- Outputterminal AssyOutput Terminal Bolt Terminal PanelTIE Bolt Terminal CoverActuator Assy DCA-100SSVU Actuator AssyActuator Bracket ActuatorFlat Head Screw Throttle ThreadBattery Assy DCA-100SSVU- Battery AssyBattery Sheet BatteryBattery Band Battery Bolt SETMuffler Assy DCA-100SSVU- Muffler AssyGasket MufflerCover BracketFuel Tank Assy DCA-100SSVU- Fueltank AssyCAP, Fuel Tank Fuel TankTank Band Supporter SheetEnclosure Assy DCA-100SSVU- Enclosure AssyUnder Cover BaseFront Frame Acoustic SheetEnclosure ASSY. DCA-100SSVU- Enclosure ASSY.Splasher Panel Over COVER, Front FrameSide Door DuctRubber Seals Assy DCA-100SSVU- Rubber Seals Assy0228900785 Nameplate and Decals Assy DCA-100SSVU- Nameplate and Decals AssyBattery Group Engine & Radiator GroupOutput Terminal Group 86 DCA-100SSVU- Operation and Parts Manual REV. #0 11/05/07 Fuel Tank Group Muffler GroupEnclosure Group EmblemEffectiveOctober 1, 2002 Terms and Conditions of Sale Parts DCA-100SSVU- Operation and Parts Manual REV. #0 11/05/07 Your Local Dealer is

DCA-100SSVU specifications

The Multiquip DCA-100SSVU is a powerful and versatile portable generator that is designed to meet the needs of a wide range of applications. Ideal for construction sites, events, and emergency power needs, this generator combines reliability with excellent performance.

One of the standout features of the DCA-100SSVU is its robust 100 kVA output, making it suitable for powering larger equipment and multiple tools simultaneously. This generator is equipped with a rugged and durable construction, ensuring it can withstand the rigors of outdoor use. Its compact design allows for easy transport and placement in tight spaces, making it an ideal choice for contractors and event planners who need a reliable power source.

The DCA-100SSVU utilizes a highly efficient diesel engine, which not only provides high performance but also ensures lower fuel consumption compared to traditional gasoline generators. This fuel efficiency translates into cost savings over time, especially for users who need extended run times. Furthermore, the generator boasts a large fuel tank capacity, allowing for longer operational periods between refuels, enhancing productivity at job sites.

In terms of technology, the DCA-100SSVU incorporates advanced sound attenuation features that significantly reduce noise levels, making it suitable for use in noise-sensitive environments such as urban areas or residential neighborhoods. Its low noise operation is not only beneficial for compliance with local regulations but also for maintaining a comfortable working environment.

The generator also comes with a user-friendly control panel, equipped with indicators for monitoring fuel levels, output voltage, and engine status, ensuring that operators can easily manage the generator's performance. This intuitive design minimizes the learning curve for new users and enhances operational efficiency.

Safety features are paramount in the DCA-100SSVU design. It includes protective circuits against overloads and short circuits, ensuring that both the generator and connected equipment remain safe during operation. Moreover, the generator is designed with ample ventilation, preventing overheating and ensuring reliable performance even in demanding conditions.

In summary, the Multiquip DCA-100SSVU is a reliable and efficient portable generator that offers impressive power output, fuel efficiency, low noise levels, and a host of user-friendly features. It is an excellent choice for professionals who require a dependable power source for various applications, making it a standout option in the generator market.