Multiquip DCA-100SSVU operation manual Tires/Wheels/Lug Nuts, TireWear/Inflation, Suspension

Page 45

DCA-100SSVU —TRAILER MAINTENANCE

Tires/Wheels/Lug Nuts

Tires and wheels are a very important and critical components of the trailer. When specifying or replacing the trailer wheels it is important the wheels, tires, and axle are properly matched.

CAUTION - EYESIGHT HAZARD

ALWAYS wear safety glasses when removing or installing force fitted parts. Failure to comply may result in serious injury.

CAUTION - REPAIRING TRAILER WHEELS

DO NOT attempt to repair or modify a wheel. DO NOT install in inner tube to correct a leak through the rim. If the rim is cracked, the air pressure in the inner

tube may cause pieces of the rim to explode (break off) with great force and cause serious eye or bodily injury.

TireWear/Inflation

Tire inflation pressure is the most important factor in tire life. Pressure should be checked cold before operation DO NOT bleed air from tires when they are hot!. Check inflation pressure weekly during use to insure the maximum tire life and tread wear.

Table 16 (Tire Wear Troubleshooting) will help pinpoint the causes and solutions of tire wear problems.

Suspension

The leaf suspension springs and associated components (Figure 60) should be visually inspected every 6,000 miles for signs of excessive wear, elongation of bolt holes, and loosening of fasteners. Replace all damaged parts (suspension) immediately. Torqued suspension components as detailed in Table 17.

Figure 60. Major Suspension Components

Table 17. Suspension Torque Requirements

Item

Torque (Ft.-Lbs.)

 

 

3/8" U-BOLT

MIN-30 MAX-35

 

 

7/16" U-BOLT

MIN-45 MAX-60

 

 

1/2" U-BOLT

MIN-45 MAX-60

 

 

SHACKLE BOLT

SNUG FIT ONLY. PARTS MUST ROTATE FREELY.

LOCKING NUTS OR COTTER PINS ARE PROVIDED

SPRING EYE BOLT

TO RETAIN NUT-BOLT ASSEMBLY.

 

 

 

SHOULDER TYPE

MIN-30 MAX-50

SHACKLE BOLT

 

 

 

DCA-100SSVU— OPERATION AND PARTS MANUAL — REV. #0 (11/05/07) — PAGE 45

Image 45
Contents Model DCA-100SSVU Parts List NO. M3870300704F2 DCA-100SSVU- Operation and Parts Manual REV. #0 11/05/07 Heres HOW to GET Help Table of Contents When ordering parts Please supply the following information Parts Ordering ProceduresDCA-100SSVU Specifications Dimensions DCA-100SSVU Dimensions TOP, Side and FrontHazard Symbols DCA-100SSVU Safety Message Alert SymbolsDCA-100SSVU Safety Message Alert Symbols DCA-100SSVU Rules for Safe Operation General SafetyElectrical Safety DCA-100SSVU Rules for Safe OperationGenerator Grounding Battery Safety Maintenance SafetyEmergencies Towing &Transporting SafetyGenerator Decals DCA-100SSVU Generator DecalsGenerator Decals Cont inued DCA-100SSVU Generator DecalsTypical Generator Grounding Application DCA-100SSVU InstallationOutdoor Installation DCA-100SSVU InstallationIndoor Installation MountingEngine Operating Panel GeneratorGenerator Control Panel Output Terminal PanelMajor Components DCA-100SSVU Major Components20 DCA-100SSVU- Operation and Parts Manual REV. #0 11/05/07 DCA-100SSVU Generator Control Panel DCA-100SSVU Engine Operating Panel DCA-100SSVU Engine Operating Panel Output Terminal Familiarization DCA-100SSVU Output Terminal Panel Familiarization100VAC Gfci Receptacles DCA-100SSVU Output Terminal Panel FamiliarizationOver Current Relay Connecting LoadsSingle Phase Load Three Phase LoadDCA-100SSVU Load Application Generator OutputVoltages Voltage Selector SwitchGenerator Amperage Gfci Receptacle Load CapabilityHow to Read the Output Terminal Gauges DCA-100SSVU Gauge ReadingReading Amperage DCA-100SSVU Output Terminal Panel Connections Three-Phase PositionUvwo Terminal Output Voltages 3Ø 240/139 Output Terminal Lug VoltagesDCA-100SSVU Output Terminal Panel Connections 3Ø 480/277 Output Terminal Lug Voltages1Ø 240V/120V Output Terminal Lug Voltages Circuit Breakers DCA-100SSVU SetupLubrication Oil Fuel CheckRefueling Refueling ProcedureAir Cleaner Fan Belt Tension Cleaning the RadiatorCoolant Antifreeze/Summer Coolant/Water Operation FreezingWeatherBattery Cable Installation BatteryWiring AlternatorBefore Starting DCA-100SSVU Generator START-UP Procedure ManualNo Load Coolant Temperature GaugeMpec Control Switch Auto Starting Auto ModeEmergency Shutdown Procedure Normal Shutdown ProcedureDCA-100SSVU Maintenance Air Removal Cleaning the Fuel StrainerCheck Oil Level Replacing Oil FilterBattery Charger JacketWater Heater Power Connections Trailer Maintenance DCA-100SSVU -TRAILER MaintenanceBrake Adjustment BrakesHydraulic Surge Brakes Tires/Wheels/Lug Nuts TireWear/InflationSuspension Lug Nut Torque Requirements DCA-100SSVU -TRAILER MaintenanceTrailer/Towing Vehicle Wiring Diagram DCA-100SSVU -TRAILERWIRING DiagramGenerator Wiring Diagram DCA-100SSVU Generatorwiring DiagramEngine Wiring Diagram DCA-100SSVU Enginewiring DiagramGenerator Troubleshooting DCA-100SSVU -TROUBLESHOOTING GeneratorEngine Controller Troubleshooting Mpec DCA-100SSVU -TROUBLESHOOTING Engine ControllerDCA-100SSVU Explanation of Code in Remarks Column Sample Parts ListDescription DCA-100SSVU Suggested Spare PartsGenerator Assy DCA-100SSVU Generator AssyFAN Field AssyCoupling Disk HEX Head BoltEngine Operating Panel Assy DCA-100SSVU- Engine Operating Panel AssyEngine Speed Switch SwitchWater Temperature Gauge SWITCH, Panel LightDCA-100SSVU- Control BOX ASSY. S/N 78000001~78000129 Circuit BREAKER, 3P 250A Switch BoardMachine Screw Relay UnitControl BOX ASSY. CONT. S/N 7800001~7800129 SET Screw Sensor TemperatureSnap Ring RELAY, DC12VControl BOX ASSY. S/N 7800130~AND Above DCA-100SSVU- Control BOX ASSY. S/N 78000130 and AboveAutomatic Voltage Reulator DCA-100SSVU- Control BOX ASSY. S/N 78000130 and AboveControl BOX ASSY. CONT. S/N 7800130~AND Above PTF08A RELAY, LY-2D DC12VPYCA1 LY2DUS12VDCEngine and Radiator Assy DCA-100SSVU- Engine and Radiator AssyDCA-100SSVU- Engine and Radiator Assy Output Terminal Assy DCA-100SSVU- Outputterminal AssyOutput Terminal Bolt Terminal PanelTIE Bolt Terminal CoverActuator Assy DCA-100SSVU Actuator AssyActuator Bracket ActuatorFlat Head Screw Throttle ThreadBattery Assy DCA-100SSVU- Battery AssyBattery Sheet BatteryBattery Band Battery Bolt SETMuffler Assy DCA-100SSVU- Muffler AssyGasket MufflerCover BracketFuel Tank Assy DCA-100SSVU- Fueltank AssyCAP, Fuel Tank Fuel TankTank Band Supporter SheetEnclosure Assy DCA-100SSVU- Enclosure AssyUnder Cover BaseFront Frame Acoustic SheetEnclosure ASSY. DCA-100SSVU- Enclosure ASSY.Splasher Panel Over COVER, Front FrameSide Door DuctRubber Seals Assy DCA-100SSVU- Rubber Seals Assy0228900785 Nameplate and Decals Assy DCA-100SSVU- Nameplate and Decals AssyBattery Group Engine & Radiator GroupOutput Terminal Group 86 DCA-100SSVU- Operation and Parts Manual REV. #0 11/05/07 Fuel Tank Group Muffler GroupEnclosure Group EmblemEffectiveOctober 1, 2002 Terms and Conditions of Sale Parts DCA-100SSVU- Operation and Parts Manual REV. #0 11/05/07 Your Local Dealer is

DCA-100SSVU specifications

The Multiquip DCA-100SSVU is a powerful and versatile portable generator that is designed to meet the needs of a wide range of applications. Ideal for construction sites, events, and emergency power needs, this generator combines reliability with excellent performance.

One of the standout features of the DCA-100SSVU is its robust 100 kVA output, making it suitable for powering larger equipment and multiple tools simultaneously. This generator is equipped with a rugged and durable construction, ensuring it can withstand the rigors of outdoor use. Its compact design allows for easy transport and placement in tight spaces, making it an ideal choice for contractors and event planners who need a reliable power source.

The DCA-100SSVU utilizes a highly efficient diesel engine, which not only provides high performance but also ensures lower fuel consumption compared to traditional gasoline generators. This fuel efficiency translates into cost savings over time, especially for users who need extended run times. Furthermore, the generator boasts a large fuel tank capacity, allowing for longer operational periods between refuels, enhancing productivity at job sites.

In terms of technology, the DCA-100SSVU incorporates advanced sound attenuation features that significantly reduce noise levels, making it suitable for use in noise-sensitive environments such as urban areas or residential neighborhoods. Its low noise operation is not only beneficial for compliance with local regulations but also for maintaining a comfortable working environment.

The generator also comes with a user-friendly control panel, equipped with indicators for monitoring fuel levels, output voltage, and engine status, ensuring that operators can easily manage the generator's performance. This intuitive design minimizes the learning curve for new users and enhances operational efficiency.

Safety features are paramount in the DCA-100SSVU design. It includes protective circuits against overloads and short circuits, ensuring that both the generator and connected equipment remain safe during operation. Moreover, the generator is designed with ample ventilation, preventing overheating and ensuring reliable performance even in demanding conditions.

In summary, the Multiquip DCA-100SSVU is a reliable and efficient portable generator that offers impressive power output, fuel efficiency, low noise levels, and a host of user-friendly features. It is an excellent choice for professionals who require a dependable power source for various applications, making it a standout option in the generator market.