Multiquip DCA-100SSVU operation manual Coolant Temperature Gauge, No Load

Page 37
Figure 53. Ammeter
(Load)

DCA-100SSVU — GENERATOR START-UP PROCEDURE (MANUAL)

5.The generator's frequency meter (Figure 45) should be displaying the 60 cycle output frequency in HERTZ.

9.The coolant temperature gauge (Figure 50) will indicate the coolant temperature. Under normal operating conditions the coolant temperature should be between 165~203 °F (74~95 °C), Green Zone.

Figure 50. Coolant

Temperature Gauge

Figure 45. Frequency Meter (Hz)

6.The generator's AC-voltmeter (Figure 47) will display the generator’s output in VOLTS. If the voltage is not within the specified tolerance, use the voltage adjustment control knob (Figure 47) to increase or decrease the desired voltage.

Figure 46. Voltmeter

Figure 47. Voltage Adjust Control Knob

7.The ammeter (Figure 48) will indicate zero amps with no load applied.When a load is applied, the ammeter will indicate the amount of current that the load is drawing from the generator.

Figure 48. Ammeter

(No Load)

10.Thetachometergauge(Figure51) will indicate the speed of the engine when the generator is operating. Under normal operating conditions this speed is approximately 1800 RPM’s.

Figure 51. Engine

Tachometer Gauge

11.Place the main, GFCI, and aux. circuit breakers in the ON position (Figure 52).

Figure 52. Main, Aux. and GFCI

Circuit Breakers (ON)

12.Observe the generator's ammeter (Figure 53) and verify it reads the anticipated amount of current with respect to the load. The ammeter will only display a current reading if a load is in use.

8.The engine oil pressure gauge (Figure 49) will indicate the oil pressure of the engine. Under normal operating conditions the oil pressure is approximately 44 to 73 psi. (303~503 kPa). When starting the genera

Figure 49. Oil

Pressure Gauge

13.The generator will run until manually stopped or an abnormal condition occurs.

DCA-100SSVU— OPERATION AND PARTS MANUAL — REV. #0 (11/05/07) — PAGE 37

Image 37
Contents Model DCA-100SSVU Parts List NO. M3870300704F2 DCA-100SSVU- Operation and Parts Manual REV. #0 11/05/07 Heres HOW to GET Help Table of Contents When ordering parts Please supply the following information Parts Ordering ProceduresDCA-100SSVU Specifications Dimensions DCA-100SSVU Dimensions TOP, Side and FrontHazard Symbols DCA-100SSVU Safety Message Alert SymbolsDCA-100SSVU Safety Message Alert Symbols DCA-100SSVU Rules for Safe Operation General SafetyDCA-100SSVU Rules for Safe Operation Electrical SafetyGenerator Grounding Battery Safety Maintenance SafetyEmergencies Towing &Transporting SafetyGenerator Decals DCA-100SSVU Generator DecalsGenerator Decals Cont inued DCA-100SSVU Generator DecalsTypical Generator Grounding Application DCA-100SSVU InstallationOutdoor Installation DCA-100SSVU InstallationIndoor Installation MountingEngine Operating Panel GeneratorGenerator Control Panel Output Terminal PanelMajor Components DCA-100SSVU Major Components20 DCA-100SSVU- Operation and Parts Manual REV. #0 11/05/07 DCA-100SSVU Generator Control Panel DCA-100SSVU Engine Operating Panel DCA-100SSVU Engine Operating Panel Output Terminal Familiarization DCA-100SSVU Output Terminal Panel Familiarization100VAC Gfci Receptacles DCA-100SSVU Output Terminal Panel FamiliarizationOver Current Relay Connecting LoadsThree Phase Load Single Phase LoadDCA-100SSVU Load Application Generator OutputVoltages Voltage Selector SwitchGenerator Amperage Gfci Receptacle Load CapabilityDCA-100SSVU Gauge Reading How to Read the Output Terminal GaugesReading Amperage DCA-100SSVU Output Terminal Panel Connections Three-Phase PositionUvwo Terminal Output Voltages 3Ø 240/139 Output Terminal Lug Voltages3Ø 480/277 Output Terminal Lug Voltages DCA-100SSVU Output Terminal Panel Connections1Ø 240V/120V Output Terminal Lug Voltages Circuit Breakers DCA-100SSVU SetupLubrication Oil Fuel CheckRefueling Refueling ProcedureAir Cleaner Fan Belt Tension Cleaning the RadiatorCoolant Antifreeze/Summer Coolant/Water Operation FreezingWeatherBattery Cable Installation BatteryWiring AlternatorBefore Starting DCA-100SSVU Generator START-UP Procedure ManualNo Load Coolant Temperature GaugeMpec Control Switch Auto Starting Auto ModeEmergency Shutdown Procedure Normal Shutdown ProcedureDCA-100SSVU Maintenance Air Removal Cleaning the Fuel StrainerCheck Oil Level Replacing Oil FilterBattery Charger JacketWater Heater Power Connections Trailer Maintenance DCA-100SSVU -TRAILER MaintenanceBrakes Brake AdjustmentHydraulic Surge Brakes TireWear/Inflation Tires/Wheels/Lug NutsSuspension Lug Nut Torque Requirements DCA-100SSVU -TRAILER MaintenanceTrailer/Towing Vehicle Wiring Diagram DCA-100SSVU -TRAILERWIRING DiagramGenerator Wiring Diagram DCA-100SSVU Generatorwiring DiagramEngine Wiring Diagram DCA-100SSVU Enginewiring DiagramGenerator Troubleshooting DCA-100SSVU -TROUBLESHOOTING GeneratorEngine Controller Troubleshooting Mpec DCA-100SSVU -TROUBLESHOOTING Engine ControllerDCA-100SSVU Explanation of Code in Remarks Column Sample Parts ListDescription DCA-100SSVU Suggested Spare PartsGenerator Assy DCA-100SSVU Generator AssyFAN Field AssyCoupling Disk HEX Head BoltEngine Operating Panel Assy DCA-100SSVU- Engine Operating Panel AssyEngine Speed Switch SwitchWater Temperature Gauge SWITCH, Panel LightDCA-100SSVU- Control BOX ASSY. S/N 78000001~78000129 Circuit BREAKER, 3P 250A Switch BoardMachine Screw Relay UnitControl BOX ASSY. CONT. S/N 7800001~7800129 SET Screw Sensor TemperatureSnap Ring RELAY, DC12VControl BOX ASSY. S/N 7800130~AND Above DCA-100SSVU- Control BOX ASSY. S/N 78000130 and AboveAutomatic Voltage Reulator DCA-100SSVU- Control BOX ASSY. S/N 78000130 and AboveControl BOX ASSY. CONT. S/N 7800130~AND Above PTF08A RELAY, LY-2D DC12VPYCA1 LY2DUS12VDCEngine and Radiator Assy DCA-100SSVU- Engine and Radiator AssyDCA-100SSVU- Engine and Radiator Assy Output Terminal Assy DCA-100SSVU- Outputterminal AssyOutput Terminal Bolt Terminal PanelTIE Bolt Terminal CoverActuator Assy DCA-100SSVU Actuator AssyActuator Bracket ActuatorFlat Head Screw Throttle ThreadBattery Assy DCA-100SSVU- Battery AssyBattery Sheet BatteryBattery Band Battery Bolt SETMuffler Assy DCA-100SSVU- Muffler AssyGasket MufflerCover BracketFuel Tank Assy DCA-100SSVU- Fueltank AssyCAP, Fuel Tank Fuel TankTank Band Supporter SheetEnclosure Assy DCA-100SSVU- Enclosure AssyUnder Cover BaseFront Frame Acoustic SheetEnclosure ASSY. DCA-100SSVU- Enclosure ASSY.Splasher Panel Over COVER, Front FrameSide Door DuctRubber Seals Assy DCA-100SSVU- Rubber Seals Assy0228900785 Nameplate and Decals Assy DCA-100SSVU- Nameplate and Decals AssyEngine & Radiator Group Battery GroupOutput Terminal Group 86 DCA-100SSVU- Operation and Parts Manual REV. #0 11/05/07 Fuel Tank Group Muffler GroupEnclosure Group EmblemEffectiveOctober 1, 2002 Terms and Conditions of Sale Parts DCA-100SSVU- Operation and Parts Manual REV. #0 11/05/07 Your Local Dealer is

DCA-100SSVU specifications

The Multiquip DCA-100SSVU is a powerful and versatile portable generator that is designed to meet the needs of a wide range of applications. Ideal for construction sites, events, and emergency power needs, this generator combines reliability with excellent performance.

One of the standout features of the DCA-100SSVU is its robust 100 kVA output, making it suitable for powering larger equipment and multiple tools simultaneously. This generator is equipped with a rugged and durable construction, ensuring it can withstand the rigors of outdoor use. Its compact design allows for easy transport and placement in tight spaces, making it an ideal choice for contractors and event planners who need a reliable power source.

The DCA-100SSVU utilizes a highly efficient diesel engine, which not only provides high performance but also ensures lower fuel consumption compared to traditional gasoline generators. This fuel efficiency translates into cost savings over time, especially for users who need extended run times. Furthermore, the generator boasts a large fuel tank capacity, allowing for longer operational periods between refuels, enhancing productivity at job sites.

In terms of technology, the DCA-100SSVU incorporates advanced sound attenuation features that significantly reduce noise levels, making it suitable for use in noise-sensitive environments such as urban areas or residential neighborhoods. Its low noise operation is not only beneficial for compliance with local regulations but also for maintaining a comfortable working environment.

The generator also comes with a user-friendly control panel, equipped with indicators for monitoring fuel levels, output voltage, and engine status, ensuring that operators can easily manage the generator's performance. This intuitive design minimizes the learning curve for new users and enhances operational efficiency.

Safety features are paramount in the DCA-100SSVU design. It includes protective circuits against overloads and short circuits, ensuring that both the generator and connected equipment remain safe during operation. Moreover, the generator is designed with ample ventilation, preventing overheating and ensuring reliable performance even in demanding conditions.

In summary, the Multiquip DCA-100SSVU is a reliable and efficient portable generator that offers impressive power output, fuel efficiency, low noise levels, and a host of user-friendly features. It is an excellent choice for professionals who require a dependable power source for various applications, making it a standout option in the generator market.