Guardian Technologies 04758-2, 04759-2, 04760-2 Introduction Inside Front Cover, Operation

Page 3

Table of Contents

Guardian Air-cooled 7 kW, 12 kW and 15 kW Generators

Introduction

Inside Front Cover

Read This Manual Thoroughly

IFC

Contents

IFC

Operation and Maintenance

............................

IFC

How to Obtain Service

IFC

Authorized Dealer Locator Number

IFC

Safety Rules

2

Standards Index

3

Section 1 – General Information

4

1.1

Unpacking/Inspection

4

1.2

Protection Systems

4

1.3

System Set LED

4

1.4

The Generator

5

1.5

Specifications

6

 

1.5.1

Generator

6

 

1.5.2

Engine

6

1.6

Fuel Requirements and Recommendations....

7

1.7

Fuel Consumption

7

1.8

Reconfiguring the Fuel System

7

 

1.8.1

7 kW, 410CC

7

 

1.8.2 12 kW and 15 kW, 990cc Engines

8

1.9

Location

8

 

1.9.1

Generator

8

 

1.9.2

Transfer Switch

9

1.10

Battery Installation

9

1.11

The Battery

9

Section 2 – Post Installation Start-up

 

 

 

and Adjustments

10

2.1

Before Initial Start-up

10

2.2

Check Transfer Switch Operation

10

2.3

Electrical Checks

10

2.4

Generator Tests Under Load

11

2.5

Checking Automatic Operation

11

2.6Adjusting the Regulator (Natural Gas Only) ..12

2.7

Engine Governor Adjustment

13

 

2.7.1

7 kW Units

13

 

2.7.2 12 kW and 15 kW Units

13

 

2.7.3

Additional Corrosion Protection

14

2.8

Voltage Regulator Adjustment

14

Section 3 – Operation

14

3.1

Break-in Procedure

14

3.2

Using the Auto/Off/Manual Switch

14

 

3.2.1

“Auto” Position

14

 

3.2.2

“Off” Position

14

 

3.2.3

“Manual” Position

14

3.3

Automatic Transfer Operation

15

3.4

Sequence of Automatic Operation

15

3.5

Manual Transfer Operation

15

 

3.5.1

Transfer to Generator

 

 

 

Power Source

15

 

3.5.2 Transfer Back to Utility

 

 

 

Power Source

16

3.6

Setting the Exercise Timer

16

3.7

Protection Systems

16

 

3.7.1 Low Oil Pressure Switch

16

 

3.7.2

High Temperature Switch

16

 

3.7.3

Overcrank

17

 

3.7.4

Overspeed

17

Section 4 – Maintenance

17

4.1

Fuse

............................................................

17

4.2

Checking the Engine Oil Level

17

4.3

Changing the Engine Oil

18

 

4.3.1

Engine Oil Recommendations

18

 

4.3.2

Oil Change Procedure

18

4.4

Changing the Oil Filter

18

4.5

Changing the Engine Air Cleaner

18

 

4.5.1 7 kW, 12 kW and 15 kW

 

 

 

Generators

18

4.6

Spark Plug(s)

19

4.7

Battery Maintenance

19

4.8

Adjusting Valve Clearance

20

4.9

Cooling System

20

4.10

Attention After Submersion

21

4.11

Corrosion Protection

21

4.12

Out of Service Procedure

21

 

4.12.1 Removal From Service

21

 

4.12.2 Return to Service

21

4.13

Service Schedule

22

Section 5 – Troubleshooting

23

5.1

Troubleshooting Guide

23

Section 6 – Electrical Data

24

Section 7 – Exploded Views and

 

 

 

Parts Lists

32

Section 8 – Mounting Dimensions

50

Section 9 – Notes

51

Section 10 – Warranty

52

 

 

Generac® Power Systems, Inc.

1

Image 3
Contents Installation Introduction Introduction Inside Front Cover Post Installation Start-up AdjustmentsMaintenance TroubleshootingGeneral Hazards ‹ Standards Index Electrical HazardsUNPACKING/INSPECTION Protection SystemsSystem SET LED Gfci GeneratorSpecifications ‹ 1.5.1 Generator‹ 1.5.2 Engine 1 7 KW, 410CC Reconfiguring the Fuel SystemFuel Requirements Recommendations Fuel ConsumptionLocation 2 12KW and 15KW, 990CC EnginesGenerator 2.1 7 kW, 12 kW and 15 kW Units Battery InstallationBattery Transfer SwitchCheck Transfer Switch Operation Before Initial START-UPElectrical Checks Checking Automatic Operation Generator Tests Under LoadDual Fuel Regulators Adjusting the Regulator Natural GAS onlyEngine Governor Adjustment 2 12 KW and 15 KW Units1 7 KW Units ‹ 3.2.2 OFF Position Voltage Regulator AdjustmentBREAK-IN Procedure ‹ 3.2.1 Auto PositionManual Transfer Operation Automatic Transfer Operation‹ 3.5.2 Transfer Back to Utility Power Source ‹ 3.7.1 LOW OIL Pressure Switch‹ 3.7.2 High Temperature Switch ‹ 3.7.4 Overspeed Checking the Engine OIL Level‹ 3.7.3 Overcrank Approximate Crank Cycle Times‹ 4.3.1 Engine OIL Recommendations ‹ 4.3.2 OIL Change ProcedureChanging the Engine OIL Changing the OIL FilterSpark Plugs Battery MaintenanceCooling System Adjusting Valve ClearanceCorrosion Protection OUT of Service Procedure‹ 4.12.2 Return to Service ‹ 4.12.1 Removal from ServiceSYSTEM/COMPONENT Procedure Frequency Service ScheduleProblem Cause Correction Troubleshooting GuideElectrical Data Customer Battery 1VA Electrical Data Connection BCR SW1 Exploded Views and Parts Lists Part NO. QTY. Description Exploded Views and Parts Lists ASSEMBLY, Potted Regulator 143 140 16A 16B Part NO. QTY Description Exploded Views and Parts Lists QTY Description 14 20 ADAPTOR, Engine Exploded Views and Parts Lists Stator 12KW Exploded Views and Parts Lists PIN, Piston D20 Exploded Views and Parts Lists SCREW, Taptite M6-1.0X8 Yellow Chrome Exploded Views and Parts Lists CASTING, Twin Regulator Housing Mounting Guardian Air-cooled 7 kW, 12 kW and 15 kW Generators California and Federal Emission Control Warranty Statement Emission Control System Warranty Warranty Schedule

04758-2, 04759-2, 04760-2 specifications

Guardian Technologies has made a significant impact in the realm of air purification with its innovative product line, including models 04758-2, 04759-2, and 04760-2. These air purifiers are designed to create a healthier environment by utilizing advanced technologies and a user-friendly design.

One of the standout features of these models is their use of UV-C light technology. This technology helps to eliminate harmful pathogens and allergens, making the air cleaner and safer for families and pets. The UV-C light works in conjunction with a true HEPA filter, which captures 99.97% of dust, pollen, smoke, mold spores, and pet dander as small as 0.3 microns. This dual-action filtration system ensures that the air circulating in your home is not only free of large particles but also sanitized.

In addition to their powerful filtration capabilities, the 04758-2, 04759-2, and 04760-2 models feature activated carbon filters. These filters are effective at absorbing odors from pets, cooking, smoke, and other household sources, thereby improving overall air quality. This makes these air purifiers ideal for homes, offices, and other indoor spaces where cleanliness is paramount.

Another key characteristic of these models is their whisper-quiet operation. Designed with user comfort in mind, the purifiers can operate at a low noise level, making them suitable for bedrooms and other quiet areas. This feature allows users to enjoy uninterrupted sleep while still benefiting from cleaner air.

The design of these air purifiers is both sleek and modern, fitting seamlessly into various interior decors. They are also equipped with indicator lights that alert users when it’s time to replace the filters, ensuring optimal performance at all times.

Moreover, Guardian Technologies has focused on energy efficiency in the manufacturing of these models. They are Energy Star certified, which means they consume less power while maintaining their high level of performance.

Overall, the Guardian Technologies 04758-2, 04759-2, and 04760-2 air purifiers offer a blend of advanced technology, effective filtration, and user-friendly features. With focused attention on air quality improvement, these models are excellent choices for those looking to enhance their indoor environment and promote healthier living.