Guardian Technologies 04758-2, 04759-2, 04760-2 owner manual Warranty Schedule

Page 56

Section 10 – Warranty

Guardian Air-cooled 7 kW, 12 kW and 15 kW Generators

GENERAC POWER SYSTEMS "TWO YEAR" LIMITED WARRANTY FOR GUARDIAN®

"PREPACKAGED EMERGENCY AUTOMATIC STANDBY GENERATORS"

For a period of two years from the date of original sale, Generac Power Systems, Inc. (Generac) warrants that its Guardian generator will be free from defects in material and workmanship for the items and period set forth below. Generac will, at its option, repair or replace any part which, upon examination, inspection and testing by Generac or a Guardian Authorized Warranty Service Dealer, is found to be defective. Any equipment that the purchaser/owner claims to be defective must be examined by the nearest Guardian Authorized Warranty Service Dealer. All transportation costs under the warranty, including return to the factory, are to be borne and prepaid by the purchaser/owner. This warranty applies only to Generac Guardian prepackaged emergency automatic standby generators sold and rated for use in "Standby" applications.

WARRANTY SCHEDULE

YEARS ONE and TWO - 100% (one hundred percent) transferable coverage on Labor and Part(s) listed (proof of purchase and main- tenance is required):

Engine - All Components Alternator - All Components Transfer System - All Components

Steel enclosures are warranted against rusting for the first year of ownership only. Damage caused after receipt of generator is the responsibility of the owner and is not covered by this warranty. Nicks, scrapes, dents or scratches to the painted enclosure should be repaired promptly by the owner.

All warranty expense allowances are subject to the conditions defined in Guardian's Warranty Policies, Procedures and Flat Rate Manual.

THIS WARRANTY SHALL NOT APPLY TO THE FOLLOWING:

Guardian generators that utilize non-Guardian/Generac replacement parts.

Guardian generators utilizing non-Guardian/Generac automatic transfer switches.

Repairs or diagnostics performed by individuals other than Guardian/Generac authorized dealers not authorized in writing by Generac Power Systems.

Any Guardian generators used as rental or trailer mounted applications.

Units used for prime power in place of existing utility power where utility power is present or in place of utility power where utility power service does not normally exist.

Costs of normal maintenance, adjustments, installation and start-up.

Steel enclosures that are rusting due to the improper installation, location in a harsh or saltwater environment or scratched where integrity of paint applied is compromised.

Failures caused by any contaminated fuels, oils, coolants or lack of proper fluid amounts.

Failures due, but not limited, to normal wear and tear, accident, misuse, abuse, negligence or improper installation. As with all mechanical devices, the Generac engines need periodic part(s) service and replacement to perform well. This warranty will not cover repair when normal use has exhausted the life of a part(s) or engine.

Failures caused by any external cause or act of God, such as collision, theft, vandalism, riot or wars, nuclear holocaust, fire, freezing, lightning, earthquake, windstorm, hail, volcanic eruption, water or flood, tornado or hurricane.

Damage related to rodent and/or insect infestation.

Products that are modified or altered in a manner not authorized by Generac in writing.

Any incidental, consequential or indirect damages caused by defects in materials or workmanship, or any delay in repair or replacement of the defective part(s).

Failure due to misapplication.

Telephone, cellular phone, facsimile, internet access or other communication expenses.

Living or travel expenses of person(s) performing service, except as specifically included within the terms of a specific unit warranty period.

Expenses related to "customer instruction" or troubleshooting where no manufacturing defect is found.

Rental equipment used while warranty repairs are being performed.

Costs incurred for equipment used for removal and/or reinstallation of generator, (i.e.; cranes, hoists, lifts, etc.)

Overnight freight costs for replacement part(s).

Overtime labor.

Starting batteries, fuses, light bulbs and engine fluids.

THIS WARRANTY IS IN PLACE OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. SPECIFICALLY, GENERAC MAKES NO OTHER WARRANTIES AS TO THE MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.

GENERAC'S ONLY LIABILITY SHALL BE THE REPAIR OR REPLACEMENT OF PART(S) AS STATED ABOVE. IN NO EVENT SHALL GENERAC BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES, EVEN IF SUCH DAMAGES ARE A DIRECT RESULT OF GENERAC'S NEGLIGENCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you.

This warranty gives you specific legal rights. You also have other rights from state to state.

GENERAC® POWER SYSTEMS, INC.

P.O. BOX 297 WHITEWATER, WI 53190

Revision (02/01/05)

Part No. 0F3985

Revision 0 (03/24/05)

Printed in U.S.A.

Image 56
Contents Installation Introduction Post Installation Start-up Adjustments MaintenanceTroubleshooting Introduction Inside Front CoverGeneral Hazards Electrical Hazards ‹ Standards IndexSystem SET LED UNPACKING/INSPECTIONProtection Systems Generator Gfci‹ 1.5.2 Engine Specifications‹ 1.5.1 Generator Reconfiguring the Fuel System Fuel Requirements RecommendationsFuel Consumption 1 7 KW, 410CCGenerator Location2 12KW and 15KW, 990CC Engines Battery Installation BatteryTransfer Switch 2.1 7 kW, 12 kW and 15 kW UnitsElectrical Checks Check Transfer Switch OperationBefore Initial START-UP Generator Tests Under Load Checking Automatic OperationAdjusting the Regulator Natural GAS only Dual Fuel Regulators1 7 KW Units Engine Governor Adjustment2 12 KW and 15 KW Units Voltage Regulator Adjustment BREAK-IN Procedure‹ 3.2.1 Auto Position ‹ 3.2.2 OFF PositionAutomatic Transfer Operation Manual Transfer Operation‹ 3.7.2 High Temperature Switch ‹ 3.5.2 Transfer Back to Utility Power Source‹ 3.7.1 LOW OIL Pressure Switch Checking the Engine OIL Level ‹ 3.7.3 OvercrankApproximate Crank Cycle Times ‹ 3.7.4 Overspeed‹ 4.3.2 OIL Change Procedure Changing the Engine OILChanging the OIL Filter ‹ 4.3.1 Engine OIL RecommendationsBattery Maintenance Spark PlugsAdjusting Valve Clearance Cooling SystemOUT of Service Procedure ‹ 4.12.2 Return to Service‹ 4.12.1 Removal from Service Corrosion ProtectionService Schedule SYSTEM/COMPONENT Procedure FrequencyTroubleshooting Guide Problem Cause CorrectionElectrical Data Customer Battery 1VA Electrical Data Connection BCR SW1 Exploded Views and Parts Lists Part NO. QTY. Description Exploded Views and Parts Lists ASSEMBLY, Potted Regulator 143 140 16A 16B Part NO. QTY Description Exploded Views and Parts Lists QTY Description 14 20 ADAPTOR, Engine Exploded Views and Parts Lists Stator 12KW Exploded Views and Parts Lists PIN, Piston D20 Exploded Views and Parts Lists SCREW, Taptite M6-1.0X8 Yellow Chrome Exploded Views and Parts Lists CASTING, Twin Regulator Housing Mounting Guardian Air-cooled 7 kW, 12 kW and 15 kW Generators California and Federal Emission Control Warranty Statement Emission Control System Warranty Warranty Schedule

04758-2, 04759-2, 04760-2 specifications

Guardian Technologies has made a significant impact in the realm of air purification with its innovative product line, including models 04758-2, 04759-2, and 04760-2. These air purifiers are designed to create a healthier environment by utilizing advanced technologies and a user-friendly design.

One of the standout features of these models is their use of UV-C light technology. This technology helps to eliminate harmful pathogens and allergens, making the air cleaner and safer for families and pets. The UV-C light works in conjunction with a true HEPA filter, which captures 99.97% of dust, pollen, smoke, mold spores, and pet dander as small as 0.3 microns. This dual-action filtration system ensures that the air circulating in your home is not only free of large particles but also sanitized.

In addition to their powerful filtration capabilities, the 04758-2, 04759-2, and 04760-2 models feature activated carbon filters. These filters are effective at absorbing odors from pets, cooking, smoke, and other household sources, thereby improving overall air quality. This makes these air purifiers ideal for homes, offices, and other indoor spaces where cleanliness is paramount.

Another key characteristic of these models is their whisper-quiet operation. Designed with user comfort in mind, the purifiers can operate at a low noise level, making them suitable for bedrooms and other quiet areas. This feature allows users to enjoy uninterrupted sleep while still benefiting from cleaner air.

The design of these air purifiers is both sleek and modern, fitting seamlessly into various interior decors. They are also equipped with indicator lights that alert users when it’s time to replace the filters, ensuring optimal performance at all times.

Moreover, Guardian Technologies has focused on energy efficiency in the manufacturing of these models. They are Energy Star certified, which means they consume less power while maintaining their high level of performance.

Overall, the Guardian Technologies 04758-2, 04759-2, and 04760-2 air purifiers offer a blend of advanced technology, effective filtration, and user-friendly features. With focused attention on air quality improvement, these models are excellent choices for those looking to enhance their indoor environment and promote healthier living.