Guardian Technologies 04758-2, 04759-2, 04760-2 owner manual SW1

Page 33

Section 6 — Electrical Data

Guardian Air-cooled 7 kW, 12 kW and 15 kW Generators

Electrical Schematic – 7 kW – Drawing No. 0D9014-C

11

C2-6

22

 

 

TX

C2-5

 

225A

 

N2

N1

240VAC

 

56VA

 

 

UTILITY

 

N2

N2

INPUT

 

 

224A

 

 

N1

12Vdc

225

 

 

 

 

23

 

 

TRANSFER

 

1VA

 

 

 

 

194

RELAY

 

 

 

COIL

224

 

N1

 

 

 

 

13

17

CUSTOMER

CONNECTIONS

11

NEUTRAL

0

17

 

 

 

23

 

 

 

 

 

22

 

 

 

 

 

 

33

 

 

15A

 

 

 

 

0

SW1

194

 

120V

 

 

POWER

 

 

 

 

 

 

 

120V

 

 

 

 

WINDING

(STATOR)

239

 

 

 

15

 

 

 

44

CB1

 

 

 

 

 

 

 

 

 

 

 

23

 

 

 

 

 

 

 

 

194

 

 

 

11

 

 

 

 

 

 

 

 

 

 

 

 

15

 

 

 

 

 

 

 

 

239

 

 

 

 

240V

 

 

 

 

 

 

 

 

15A

 

 

15

 

 

 

 

 

 

 

 

13

 

 

 

 

RED

 

17

 

0

C1-2

 

SC

 

 

 

 

 

 

 

 

 

 

 

 

 

14

 

 

14

 

 

 

 

 

56

 

 

56

14

 

 

 

 

18

 

 

C1-1

 

 

 

 

 

 

 

 

 

 

 

 

SM

BATTERY

 

 

 

 

 

 

 

12V

 

 

 

SC

FS

 

 

 

 

 

 

 

 

0

0

0

 

 

 

 

17

 

18

 

 

 

 

 

 

 

 

 

 

 

15

 

 

 

C1-6

 

 

 

0

 

0

 

 

 

 

BLACK

 

 

 

 

 

 

 

 

 

 

18

 

 

IM

 

CUSTOMER

 

 

 

 

 

 

SUPPLIED

 

 

 

 

 

 

 

 

 

C1-5

D

SP

 

Generac® Power Systems, Inc. 31

Image 33
Contents Installation Introduction Maintenance Post Installation Start-up AdjustmentsTroubleshooting Introduction Inside Front CoverGeneral Hazards ‹ Standards Index Electrical HazardsUNPACKING/INSPECTION Protection SystemsSystem SET LED Gfci GeneratorSpecifications ‹ 1.5.1 Generator‹ 1.5.2 Engine Fuel Requirements Recommendations Reconfiguring the Fuel SystemFuel Consumption 1 7 KW, 410CCLocation 2 12KW and 15KW, 990CC EnginesGenerator Battery Battery InstallationTransfer Switch 2.1 7 kW, 12 kW and 15 kW UnitsCheck Transfer Switch Operation Before Initial START-UPElectrical Checks Checking Automatic Operation Generator Tests Under LoadDual Fuel Regulators Adjusting the Regulator Natural GAS onlyEngine Governor Adjustment 2 12 KW and 15 KW Units1 7 KW Units BREAK-IN Procedure Voltage Regulator Adjustment‹ 3.2.1 Auto Position ‹ 3.2.2 OFF PositionManual Transfer Operation Automatic Transfer Operation‹ 3.5.2 Transfer Back to Utility Power Source ‹ 3.7.1 LOW OIL Pressure Switch‹ 3.7.2 High Temperature Switch ‹ 3.7.3 Overcrank Checking the Engine OIL LevelApproximate Crank Cycle Times ‹ 3.7.4 OverspeedChanging the Engine OIL ‹ 4.3.2 OIL Change ProcedureChanging the OIL Filter ‹ 4.3.1 Engine OIL RecommendationsSpark Plugs Battery MaintenanceCooling System Adjusting Valve Clearance‹ 4.12.2 Return to Service OUT of Service Procedure‹ 4.12.1 Removal from Service Corrosion ProtectionSYSTEM/COMPONENT Procedure Frequency Service ScheduleProblem Cause Correction Troubleshooting GuideElectrical Data Customer Battery 1VA Electrical Data Connection BCR SW1 Exploded Views and Parts Lists Part NO. QTY. Description Exploded Views and Parts Lists ASSEMBLY, Potted Regulator 143 140 16A 16B Part NO. QTY Description Exploded Views and Parts Lists QTY Description 14 20 ADAPTOR, Engine Exploded Views and Parts Lists Stator 12KW Exploded Views and Parts Lists PIN, Piston D20 Exploded Views and Parts Lists SCREW, Taptite M6-1.0X8 Yellow Chrome Exploded Views and Parts Lists CASTING, Twin Regulator Housing Mounting Guardian Air-cooled 7 kW, 12 kW and 15 kW Generators California and Federal Emission Control Warranty Statement Emission Control System Warranty Warranty Schedule

04758-2, 04759-2, 04760-2 specifications

Guardian Technologies has made a significant impact in the realm of air purification with its innovative product line, including models 04758-2, 04759-2, and 04760-2. These air purifiers are designed to create a healthier environment by utilizing advanced technologies and a user-friendly design.

One of the standout features of these models is their use of UV-C light technology. This technology helps to eliminate harmful pathogens and allergens, making the air cleaner and safer for families and pets. The UV-C light works in conjunction with a true HEPA filter, which captures 99.97% of dust, pollen, smoke, mold spores, and pet dander as small as 0.3 microns. This dual-action filtration system ensures that the air circulating in your home is not only free of large particles but also sanitized.

In addition to their powerful filtration capabilities, the 04758-2, 04759-2, and 04760-2 models feature activated carbon filters. These filters are effective at absorbing odors from pets, cooking, smoke, and other household sources, thereby improving overall air quality. This makes these air purifiers ideal for homes, offices, and other indoor spaces where cleanliness is paramount.

Another key characteristic of these models is their whisper-quiet operation. Designed with user comfort in mind, the purifiers can operate at a low noise level, making them suitable for bedrooms and other quiet areas. This feature allows users to enjoy uninterrupted sleep while still benefiting from cleaner air.

The design of these air purifiers is both sleek and modern, fitting seamlessly into various interior decors. They are also equipped with indicator lights that alert users when it’s time to replace the filters, ensuring optimal performance at all times.

Moreover, Guardian Technologies has focused on energy efficiency in the manufacturing of these models. They are Energy Star certified, which means they consume less power while maintaining their high level of performance.

Overall, the Guardian Technologies 04758-2, 04759-2, and 04760-2 air purifiers offer a blend of advanced technology, effective filtration, and user-friendly features. With focused attention on air quality improvement, these models are excellent choices for those looking to enhance their indoor environment and promote healthier living.