Guardian Technologies 04758-2, 04759-2, 04760-2 owner manual Bcr

Page 32

Section 6 — Electrical Data

Guardian Air-cooled 7 kW, 12 kW and 15 kW Generators Electrical Schematic – 7 kW – Drawing No. 0D9014-C

11

22

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

BATTERY

 

 

225B

 

 

 

 

 

 

F2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHARGER

 

 

224B

 

 

 

 

13A

 

13

 

 

 

 

 

 

 

 

 

 

 

 

 

13A

 

 

 

 

2

 

225A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F1

 

 

 

 

 

1

 

9

9

 

7

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BCR

 

 

11

0

 

 

 

 

 

 

 

1

6

3

4

 

 

 

 

 

 

 

 

224A

 

 

 

 

 

 

 

 

 

 

13A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

77

 

 

 

 

 

 

 

77

 

C2-1

 

 

 

 

 

 

 

 

0

14

 

 

 

BATTERY CHARGE

 

 

 

 

66

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

WINDING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

66

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

22

 

 

 

 

 

 

0

C2-2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

22 225A

224A 225

224

13

15

0

ELECTRONIC

VOLTAGE

REGULATOR

C2-4

55

11

 

 

BA

 

22

0

 

FIELD

 

 

 

 

0

4

C2-10

C2-9

 

4

 

0

 

 

 

 

0

 

6

 

 

162

C2-11

 

CB2

6

 

 

0

2

C2-7

6

C2-8

2

 

 

DPE WINDING

 

(STATOR)

DIAGRAM KEY

BA - BRUSH ASSEMBLY

BCR - BATTERY CHARGE RELAY

CB1 - CIRCUIT BREAKER, MAIN OUTPUT CB2 - CIRCUIT BREAKER, ALT. EXCITATION D - DIODE

FS - FUEL SOLENOID F1 - FUSE 15 AMP F2 - FUSE 5 AMP

HTO - HIGH OIL TEMPERATURE SWITCH HM - HOUR RUN METER

IM - IGNITION MODULE

LOP - LOW OIL PRESSURE SWITCH SC - STARTER CONTACTER

SP - SPARK PLUG

SW1 - AUTO / OFF / MANUAL SWITCH SW2 - SET EXERCISE SWITCH

SM - STARTER MOTOR

TX - TRANSFORMER, 16 Vac 56 VA & 16 Vac 1 VA (DUAL SEC.)

 

HTO

0

0

 

 

 

0

 

 

 

 

 

 

 

LOP

ENGINE RUN

C1-4

 

 

SW2

 

 

WINDING

 

 

 

 

 

 

 

 

 

14

(STATOR)

 

 

 

 

 

 

C2-3

 

 

 

 

C1-3

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

66A

 

 

 

 

 

 

 

 

85

 

 

 

 

 

 

 

 

 

 

 

 

86

 

 

351

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

66A

 

 

 

1

2

3

4

5

 

 

 

 

 

J2

 

 

 

 

 

 

 

 

 

1

4

23

 

 

 

 

 

 

 

 

 

 

 

J1

86

194

 

 

 

 

 

 

 

 

 

 

 

3

 

23

 

 

 

 

 

4

 

194

 

 

 

 

 

5

 

56

 

 

 

 

 

6

 

18

 

CONTROL

 

8

66A

 

 

 

 

239

 

PRINTED CIRCUIT

 

 

 

 

BOARD

 

 

10

 

15A

 

 

 

 

 

11

 

17

 

 

 

 

 

12

 

15

 

 

 

 

 

13

 

0

 

 

 

 

 

 

 

225

 

 

 

 

 

15

 

224

 

 

 

 

 

16

 

 

 

 

 

 

 

17

 

 

15

23

194

225 14

224

66A

239

30 Generac® Power Systems, Inc.

Image 32
Contents Installation Introduction Post Installation Start-up Adjustments MaintenanceTroubleshooting Introduction Inside Front CoverGeneral Hazards Electrical Hazards ‹ Standards IndexSystem SET LED UNPACKING/INSPECTIONProtection Systems Generator Gfci‹ 1.5.2 Engine Specifications‹ 1.5.1 Generator Reconfiguring the Fuel System Fuel Requirements RecommendationsFuel Consumption 1 7 KW, 410CCGenerator Location2 12KW and 15KW, 990CC Engines Battery Installation BatteryTransfer Switch 2.1 7 kW, 12 kW and 15 kW UnitsElectrical Checks Check Transfer Switch OperationBefore Initial START-UP Generator Tests Under Load Checking Automatic OperationAdjusting the Regulator Natural GAS only Dual Fuel Regulators1 7 KW Units Engine Governor Adjustment2 12 KW and 15 KW Units Voltage Regulator Adjustment BREAK-IN Procedure‹ 3.2.1 Auto Position ‹ 3.2.2 OFF PositionAutomatic Transfer Operation Manual Transfer Operation‹ 3.7.2 High Temperature Switch ‹ 3.5.2 Transfer Back to Utility Power Source‹ 3.7.1 LOW OIL Pressure Switch Checking the Engine OIL Level ‹ 3.7.3 OvercrankApproximate Crank Cycle Times ‹ 3.7.4 Overspeed‹ 4.3.2 OIL Change Procedure Changing the Engine OILChanging the OIL Filter ‹ 4.3.1 Engine OIL RecommendationsBattery Maintenance Spark PlugsAdjusting Valve Clearance Cooling SystemOUT of Service Procedure ‹ 4.12.2 Return to Service‹ 4.12.1 Removal from Service Corrosion ProtectionService Schedule SYSTEM/COMPONENT Procedure FrequencyTroubleshooting Guide Problem Cause CorrectionElectrical Data Customer Battery 1VA Electrical Data Connection BCR SW1 Exploded Views and Parts Lists Part NO. QTY. Description Exploded Views and Parts Lists ASSEMBLY, Potted Regulator 143 140 16A 16B Part NO. QTY Description Exploded Views and Parts Lists QTY Description 14 20 ADAPTOR, Engine Exploded Views and Parts Lists Stator 12KW Exploded Views and Parts Lists PIN, Piston D20 Exploded Views and Parts Lists SCREW, Taptite M6-1.0X8 Yellow Chrome Exploded Views and Parts Lists CASTING, Twin Regulator Housing Mounting Guardian Air-cooled 7 kW, 12 kW and 15 kW Generators California and Federal Emission Control Warranty Statement Emission Control System Warranty Warranty Schedule

04758-2, 04759-2, 04760-2 specifications

Guardian Technologies has made a significant impact in the realm of air purification with its innovative product line, including models 04758-2, 04759-2, and 04760-2. These air purifiers are designed to create a healthier environment by utilizing advanced technologies and a user-friendly design.

One of the standout features of these models is their use of UV-C light technology. This technology helps to eliminate harmful pathogens and allergens, making the air cleaner and safer for families and pets. The UV-C light works in conjunction with a true HEPA filter, which captures 99.97% of dust, pollen, smoke, mold spores, and pet dander as small as 0.3 microns. This dual-action filtration system ensures that the air circulating in your home is not only free of large particles but also sanitized.

In addition to their powerful filtration capabilities, the 04758-2, 04759-2, and 04760-2 models feature activated carbon filters. These filters are effective at absorbing odors from pets, cooking, smoke, and other household sources, thereby improving overall air quality. This makes these air purifiers ideal for homes, offices, and other indoor spaces where cleanliness is paramount.

Another key characteristic of these models is their whisper-quiet operation. Designed with user comfort in mind, the purifiers can operate at a low noise level, making them suitable for bedrooms and other quiet areas. This feature allows users to enjoy uninterrupted sleep while still benefiting from cleaner air.

The design of these air purifiers is both sleek and modern, fitting seamlessly into various interior decors. They are also equipped with indicator lights that alert users when it’s time to replace the filters, ensuring optimal performance at all times.

Moreover, Guardian Technologies has focused on energy efficiency in the manufacturing of these models. They are Energy Star certified, which means they consume less power while maintaining their high level of performance.

Overall, the Guardian Technologies 04758-2, 04759-2, and 04760-2 air purifiers offer a blend of advanced technology, effective filtration, and user-friendly features. With focused attention on air quality improvement, these models are excellent choices for those looking to enhance their indoor environment and promote healthier living.