Generac Power Systems 005040-0, 005040-1, 005053-0, 005053-1, 005054-0, 005054-1 0C2267

Page 43
Manual background

Section 8 - Exploded Views and Parts

Guardian Liquid-cooled 25 kW Generator Control Panel — Drawing No. 0F1378-D

ITEM

PART NO.

QTY.

DESCRIPTION

1

0C2267

16

SCREW HHTT M5-0.8 X 12 BP

2

064733

2

RES MTG BRACKET

3

0D5070A

1

ASSY 2A 12V UL BATTERY

 

 

 

CHARGER

4

0D8671

1

HINGE CONTINUOUS 1.5L CTRL PNL

5

0E4494

1

SWITCH ROC DPDT ON-OFF-ON

6

0E6875A

2

RELAY 12VDC C FORM W/DIODE

7

0E7358

4

SCREW PPPH HI-LO #4-24 X 3/8

8

0E9704

1

ASSY PCB HSB CONTROLLER 2.5L

9

0E9934

1

CTRL PNL BACK & BOTTOM 2.5L

10

0E9935

1

CTRL PNL LH SIDE 2.5L FORD

11

0E9936

1

CTRL PNL RH SIDE 2.5L FORD

12

0E9937

1

CTRL PNL TOP 2.5L FORD

13

0E9938

1

CTRL PNL FRONT 2.5L FORD

14

023897

19

WASHER FLAT #10 ZINC

15

036261

4

RIVET POP .125 X .275 AL

16

048468

1

CIRCT BRK 8 X 1 ETA 46-500-P

17

057073

1

JUNCTION BLOCK 3/8-16

18

067680

1

ASSY VOLTAGE REGULATOR 60HZ

19

082573

1

SWITCH ROC DPST 125V SPD

20

0C3910

1

TRANSFORMER 240/16V 1VA & 56VA

21

029673

1

DIO BRIDGE 25A 600V

22

034616

1

FITTING STRAIGHT 3/4

23

0E2514

1

FITTING CONDUIT STR 1-1/2"

24

0F0581

1

BRACKET FUSE HOLDER 2.5L FORD

25

040213

2

PCB SUPPORT SNAP-IN 1/4"

26

0F0558

1

BRACKET PCB SUPPORT 2.5L FORD

27

0F0598

1

DECAL FUSES 2.5L CNTRL PANEL

28

0F0599

1

DECAL TB1 2.5L CONTROL PANEL

29

0F0600

1

DECAL ICT 2.5L CONTROL PANEL

30

054199

1

DECAL DANGER HIGH VOLTAGE

31

049813

1

NUT HEX M6 X 1.0 G8 YEL CHR

32

0F0653

1

DECAL CONTROL HSB 2.5L FORD

33

022097

3

WASHER LOCK M6-1/4

34

0C2212

9

SCREW PHTT M4-0.7 X 16 ZYC

ITEM

PART NO.

QTY.

DESCRIPTION

35

022264

22

WASHER LOCK #8-M4

36

0C2265

13

SCREW PHTT M4-0.7 X 12 ZYC

37

023965

2

SCREW RHM #8-32 X 3/8

38

039782

1

BRKT MTG CB BQ

39

0D5544

1

CB 0100A 2P 240V S BQ2 LL (20KW)

 

0D5541

1

CB 0070A 2P 240V S BQ2 LL (15KW)

40

020911

2

SCREW PPHM M5-0.8 X 30 ZINC

41

0A8955

2

SCREW PHM M6-1.0 X 20MM

42

022152

3

WASHER LOCK #10

43

051716

2

NUT HEX M5-0.8 G8 YEL CHR

44

023762

1

WASHER SHAKEPROOF EXT #10

 

 

 

STL

45

033121

1

SCREW HHC #10-32 X 1/2

46

026850

1

WASHER SHAKEPROOF EXT 1/4

 

 

 

STL

47

0912970087

1

ASSY WIRE 14AWG 16" #0 GRN/YEL

48

022158

1

NUT HEX #10-32 STEEL

49

0E7403C

1

FUSE ATO TYPE 15 AMP (BLUE)

50

0E7403A

1

FUSE ATO TYPE 5 AMP (TAN)

51

0F0526A

1

HARN CTRL PNL 2.5L FD (NOT

 

 

 

SHOWN)

52

0A2115

2

WASHER NYLON .257

53

022473

2

WASHER FLAT 1/4-M6 ZINC

54

048352

1

RES 5R 5% 25W

55 *

046357

REF

BLOCK TERM 20A 6 X 6 X 1100V

56 *

047822

REF

BLOCK TERM 20A 7 X 6 X 1100V

57 *

0F1467

REF

ASSY WIRE FUSE HOLDER

58 *

0E6881

REF

SOCKET RELAY

59 **

049226

2

WASHER LOCK M5

60 **

051716

2

NUT HEX M5-0.8 G8 YEL CHR

61 **

052619

2

SCREW HHC M5-0.8 X 20 G8.8

62 **

023897

4

WASHER FLAT #10 ZINC

*PART OF I/N 51, P/N 0F0526A CONTROL PANEL HARNESS.

**NOT SHOWN. HARDWARE FOR ATTACHING WIRES TO I/N 39.

Generac® Power Systems, Inc. 41

Image 43
Contents This manual should remain with the unit SHOULD ATTEMPT INSTALLATIONOwner’s Manual Liquid-cooled,Prepackaged Standby GeneratorsINTRODUCTION AUTHORIZED SERVICE DEALER LOCATION‹OPERATION AND MAINTENANCE ‹HOW TO OBTAIN SERVICEINTRODUCTION Table of ContentsDespite the safe design of this generator GENERAL HAZARDSParts of the generator are rotating and/or hot ‹STANDARDS INDEX ELECTRICAL HAZARDSFIRE HAZARDS EXPLOSION HAZARDS1.4GENERATOR AC CONNECTION SYSTEMS 1.2TRANSFER SWITCH1.1GENERATOR 1.3AUTOMATIC SYSTEM OPERATIONFigure 1.4 - Low Oil Pressure Switch ‹1.7.1 LOW OIL PRESSURE SWITCH‹1.7.2 HIGH COOLANT TEMPERATURE SWITCH ‹1.7.3 LOW COOLANT LEVEL SWITCH1.8UNPACKING 1.10 SPECIFICATIONS‹1.7.6 LOW BATTERY ‹1.8.1 UNPACKING PRECAUTIONS‹ 1.10.2 GENERATOR 1.12RECONFIGURING THE FUEL SYSTEM FOR LP VAPORFigure 1.8 — Reconfigure the Fuel System 1.11 FUEL CONSUMPTION1.14 COOLANT RECOMMENDATIONS 1.15 BEFORE INSTALLATION2.1STANDBY GENERATOR INSTALLATION 1.13 ENGINE OIL RECOMMENDATIONS‹2.1.2 OTHER PUBLISHED STANDARDS 2.3GENERATOR MOUNTING AND SUPPORT2.4BASIC STANDBY ELECTRIC SYSTEM 2.2GENERATOR LOCATION2.7GROUNDING THE GENERATOR 2.9USING AN ENGINEERED “GTS” TRANSFER SWITCH2.5EMERGENCY CIRCUIT ISOLATION METHOD 2.6TOTAL CIRCUIT ISOLATION METHODStandby generators installed with automatic 2.10BATTERY INSTALLATIONPos2 OFF — Standard Prepackaged ATS Application ‹2.10.1 VENTED BATTERIES‹2.11.1 PRIOR TO INITIAL START-UP 3.1ENGINEERED GTS TRANSFER SWITCH‹2.11.2 TRANSFER SWITCH 2.11 PREPARATION BEFORE START-UP3.2CONTROL CONSOLE COMPONENTS ‹3.2.2 FAULT INDICATOR LEDS‹3.2.1 AUTO/OFF/MANUAL SWITCH ‹3.2.5 SET EXERCISE TIME SWITCH3.3MANUAL TRANSFER AND START-UP 3.4ENGINE GOVERNOR ADJUSTMENTS‹3.2.6 SYSTEM READY LED 3.7WEEKLY EXERCISE CYCLE Figure 3.2 — Engine Governor AdjustmentFigure 3.3 - “Set Exercise Time” Switch 3.6AUTOMATIC OPERATIONC. ONCE ANNUALLY 3.8CONTROL BOARD DIP SWITCH SETTINGSA. EVERY THREE MONTHS B. ONCE EVERY SIX MONTHSFigure 4.1 — Intake Manifold Installation 4.2EXHAUST MANIFOLD PROCEDURE4.3INTAKE MANIFOLD PROCEDURE 4.4CYLINDER HEAD PROCEDURE4.7CHECKING FLUID LEVELS 4.8MAINTENANCE OWNER/ OPERATOR CAN PERFORM4.6OVERLOAD PROTECTION FOR ENGINE DC ELECTRICAL SYSTEM‹4.8.9 INSPECT ENGINE GOVERNOR ‹4.8.11 CHANGING THE ENGINE AIR CLEANERFigure 4.4 – Setting the Spark Plug Gap ‹4.8.8 CHECK FAN BELT‹4.9.3 BATTERY MAINTENANCE 4.9MISCELLANEOUS MAINTENANCE‹4.9.1 CLEANING THE GENERATOR ‹4.9.2 BATTERYService Maintenance Interval Information 4.10 SCHEDULED MAINTENANCELevel MaintenanceTasks Maintenance CORRECTION TROUBLESHOOTING POINTSPROBLEM CAUSESection 6 — Notes Section 7 - Electrical Data 26 Generac Power Systems, IncSection 7 - Electrical Data 28 Generac Power Systems, Inc Section 7 - Electrical Data 30 Generac Power Systems, Inc Section 7 - Electrical Data 32 Generac Power Systems, Inc Section 7 - Electrical Data MOUNT PART NO ITEMDESCRIPTION 31 7 11 Enclosure — Drawing No. 0E9720-D 54 36 30 0C2267 40 Generac Power Systems, Inc 0C2267 Engine — Drawing No. 0E9918-E 42 Generac Power Systems, Inc0E9909 0E1028A I/N 0E8456 LOCKTIGHT 0F1659A Muffler — Drawing No. 0F2930-B Stepper Motor — Drawing No. 0E9979-C Radiator — Drawing No. 0E9965-D Installation Diagram — Drawing No. 0F1020-A Section 9 — Installation DiagramCALIFORNIA EMISSION CONTROL WARRANTY STATEMENT YOUR WARRANTY RIGHTS AND OBLIGATIONSPURCHASER’S/OWNER’S WARRANTY RESPONSIBILITIES 1-800-333-1322EMISSION RELATED PARTS INCLUDE THE FOLLOWING EMISSION CONTROL SYSTEM WARRANTYP.O. BOX 297 • WHITEWATER, WI WARRANTY SCHEDULETHIS WARRANTY SHALL NOT APPLY TO THE FOLLOWING GENERAC POWER SYSTEMS, INC