Generac Power Systems 004700-00 owner manual Checking the Engine OIL Level

Page 13

Section 3 – Maintenance

Recreational Vehicle Generator

‹2.10.4 OPERATION IN HIGH GRASS OR BRUSH

3.1CHECKING THE ENGINE OIL LEVEL

Never operate the generator while the vehicle is parked over high grass, weeds, brush, leaves or any other combustible substance. Such materials can ignite and burn from the heat of the exhaust system. The generator exhaust system becomes extremely hot during operation and remains hot for a long time after it has shut down.

‹2.10.5 EFFECTS OF MOISTURE AND DIRT

Keep the generator set as clean and dry as possible. Protect the unit against excessive dust, dirt, corrosive vapors, road splash, etc. Permitting dirt and mois- ture to accumulate on generator windings will have an adverse effect on the insulation resistance of those windings.

When moisture is allowed to remain in contact with windings, some of the moisture will be retained in voids and cracks in the insulation. This causes a reduced insulation resistance and will eventually cause problems. Dirt will make the problem worse, since dirt tends to hold moisture in contact with windings. Salt (as from sea air) also will worsen the problem since it tends to absorb moisture from the air. Salt and moisture, when combined, form a good electrical conductor.

For oil capacities and requirements, see “Engine Oil Requirements,” Section 1.5.4. Check the engine crankcase oil level at least every eight hours of opera- tion, or before each use. To check the engine oil level, proceed as follows (see Figure 3.1):

1.Be sure the generator is as level as possible.

2.Remove the dipstick and wipe it dry with a clean, lint-free cloth.

3.Install and tighten the dipstick cap; then, remove it again. The oil level should be at the dipstick “Full” mark.

4.If necessary, remove the oil fill cap on the rocker cover and slowly add oil until it reaches the dip- stick “Full” mark. DO NOT FILL ABOVE THE “FULL” MARK.

Never operate the engine with the oil level below the “Add” mark on the dipstick. Doing this could damage the engine.

5.Install and tighten the oil fill cap and the dipstick before operating the engine.

3.2CHANGING THE ENGINE OIL

AND/OR OIL FILTER

Change the engine oil after the first 25 hours of operation (after the 25-hour break-in period, see Section 2.10.1). Thereafter, change the oil every 100 operating hours. Change the oil more fre- quently if operating consistently under heavy load or at high ambient temperatures.

Figure 3.1 – Oil Maintenance Features

G

GENERAC

E N E

OHVIPOWERED

e r ,

W

I

R A C

P o w e r S y s t e m s , I n c .- W h it e

w a t

 

 

 

 

 

 

 

 

GENERAC OHVI INDUSTRIAL ENGINE

QUIETPACTTM40G

RV SERVICE LOCATOR: 1.800.333.1322

Oil Dipstick/Oil Fill

 

 

CONTROL CENTER

 

 

 

S T A R T

F U E L

C . B .

 

 

3 0 A

 

 

S T O P

P R I M E

 

 

 

 

F U S E

 

 

 

 

7.5 A

 

 

 

S E R V IC E A C C E S S P A N E L

 

 

AIR FILTER LOCATED BEHIND PANEL.

 

 

 

MAINTENANCE SCHEDULE

 

 

 

OIL LEVEL:

CHECK DAILY

 

 

 

AIR FILTER:

CLEAN PREFILTER

 

 

 

EVERY 100 HOURS. *

 

 

 

REPLACE ELEMENT

 

 

 

EVERY 250 HOURS. *

 

 

OIL & OIL FILTER:

CHANGE EVERY 100

 

 

 

HOURS. (OR ANNUALLY) *

 

 

 

*

 

 

 

SPARK PLUGS:

INSPECT & CLEAN

 

 

 

PLUGS EVERY 100

 

 

 

HOURS. REPLACE PLUGS

 

 

 

EVERY 500 HOURS.

 

 

 

(IF NECESSARY)

 

 

 

FUEL FILTER:

CHANGE EVERY 400

 

 

 

HOURS. (OR ANNUALLY)

To

R

REPLACEMENT INFORMATION

 

 

e

PREFILTER P/N:

 

0D4511

 

m

AIR FILTER P/N:

 

0D3262

 

o

OIL FILTER P/N:

 

070185

 

SPARK PLUG P/N:

 

072347

 

v

FUEL FILTER P/N:

 

0D7515

 

e

OIL CAPACITY WITH FILTER:

0.8L/0.84QT

 

 

TEMPERATURE

SAE VISCOSITY

 

 

32˚F AND HIGHER

 

30

 

 

10˚F TO 100˚F

 

15W-40

 

 

0˚F TO 80˚F

 

10W-30

 

 

-20˚F TO 50˚F

 

5W-30

 

 

WHEN SERVICE OR PARTS ARE NEEDED IN

 

 

 

THE USA OR CANADA, CONTACT THE GENERAC

 

 

 

SERVICE LOCATOR AT 1-800-333-1322.

 

Oil Drain

Oil Filter

11

Image 13
Contents Air-cooled Recreational Vehicle Generators Introduction Authorized Service Dealer LocationInside Front Cover Part II Installation Instructions Warning   Electrical Hazards  Model Generator IdentificationSpecifications SafetyGenerator Applicability Generator AC Connection System‹ 1.5.2 Fuel Consumption ‹ 1.5.5 Generator‹ 1.5.3 Engine OIL Requirements ‹ 1.5.6 Emissions Compliance PeriodOptional Remote START/STOP Panel Generator Control PanelAutomatic Choke Before Starting the Engine‹ 2.4.2 Engine Lubrication Starting the Generator‹ 2.4.3 Fuel Supply ‹ 2.4.4 Cooling and Ventilating AIRDo not Overload Generator Stopping the GeneratorProtection Systems ‹ 2.9.3 Field Boost Additional Information‹ 2.10.1 25-HOUR BREAK-IN Period ‹ 2.9.4 Overvoltage ProtectionChanging the Engine OIL AND/OR OIL Filter Checking the Engine OIL Level‹ 2.10.4 Operation in High Grass or Brush ‹ 2.10.5 Effects of Moisture and Dirt‹ 3.3.1 Cleaning the Foam Precleaner Maintaining the Engine AIR CleanerClean Spark Arrestor Clean AIR IntakeChecking the Engine Spark Plug Fuel FilterBattery Maintenance Cleaning the Generator‹ 3.9.1 Weekly ‹ 3.9.2 Every SIX MonthsAdjusting Valve Clearance OUT of Service Procedure‹ 3.12.1 Removal from Service ‹ 3.12.2 Return to ServiceTightening Jam Nut RV Generator Service IntervalPart  General Hazards   Fire Hazards  Equipment Description Purpose and Scope ManualGenerator Engine Operating Speed Standards Booklets0D8716 ‹ 2.1.1 Generator Location Location and Support‹ 2.1.2 Generator Support ‹ 2.1.4 Generator Restraint Generator Compartments‹ 2.2.2 Compartment Construction ‹ 2.2.1 Compartment Size‹ 2.2.3 Sound Insulating Materials ‹ 2.2.4 AcousticsView from TOP ‹ 2.2.5 Compartment Floor CutoutsCooling and Ventilating AIR ‹ 2.3.1 Generator Airflow ‹ 2.3.2 Testing the InstallationGasoline Fuel System ‹ 2.4.1 Fuel Tank Exhaust System‹ 2.4.2 Generator Fuel Supply Line Rigid Fuel LinesElectrical Connections ‹ 2.5.2 Exhaust System Safety‹ 2.5.1 Spark Arrestor ‹ 2.6.1 Electrical Junction BOX ‹ 2.6.2 Wiring‹ 2.6.3 Generator AC Connections ‹ 2.6.4 Conduit‹ 2.6.6 Power Supply Cord ‹ 2.6.5 Isolating Different Power Sources‹ 2.7.1 Recommended Battery Battery Installation‹ 2.7.2 Battery Cables ‹ 2.7.3 Battery Cable ConnectionsTesting Under Load Post Installation TestsInitial Start Before Initial START-UPInstallation Checklist Appendix 1 Notes Problem Cause Correction Troubleshooting GuideAppendix 3 Electrical Data Supplied by Customer To Carb Part NO. QTY Description 21 2 QTY Description 274 Regulator Voltage Appendix 4 Exploded Views and Parts Lists GUARD, FAN Appendix 4 Exploded Views and Parts Lists Long Block Assembly MANUFACTURER’S Emission Control System Warranty Coverage Your Warranty Rights and ObligationsPURCHASER’S/OWNER’S Warranty Responsibilities Emission Related Parts Include the Following Emission Control System WarrantyWarranty Schedule CONSUMER/PERSONAL Applications

004700-00 specifications

Generac Power Systems is a recognized leader in the field of backup power generation, and one of its standout products is the Generac 004700-00. This reliable and high-performance generator has garnered attention for its robust features and advanced technological capabilities, making it an appealing choice for homeowners and businesses alike.

One of the key features of the Generac 004700-00 is its ability to deliver a reliable source of power during outages. With a powerful engine, this generator is designed to handle substantial loads, including sensitive electronics, heating systems, and appliances without compromising performance. The generator achieves this with a recommended horsepower rating that ensures a steady output even under heavy demand.

Incorporating Generac’s advanced Synch Power technology, the 004700-00 enables users to operate multiple devices simultaneously without any disruption. This feature ensures that the power provided is stable and consistent, minimizing the risk of damage to electronic devices during surges or fluctuations. Furthermore, the generator is engineered with a user-friendly control panel, making it easy to monitor performance metrics and adjust settings as necessary.

A standout characteristic of the 004700-00 is its quiet operation. Unlike many traditional generators, this unit utilizes noise-reducing technologies, ensuring that it operates at a lower decibel level. This feature is particularly beneficial for residential areas, where noise restrictions may be a concern.

The Generac 004700-00 also excels in fuel efficiency, allowing it to run longer on less fuel. This is achieved through its advanced engine design and efficient fuel consumption rate, which not only saves on operating costs but also reduces the environmental impact. Additionally, the generator is compatible with various fuel types, enhancing its versatility and convenience for users.

Ease of maintenance is another consideration with the 004700-00, as it is equipped with a maintenance alert system that notifies users when service is required. This proactive approach to care ensures that the generator remains in optimal working condition, prolonging its lifespan and reliability.

In summary, the Generac Power Systems 004700-00 stands out with its powerful performance, advanced technology, quiet operation, fuel efficiency, and user-friendly features. Whether for residential or commercial use, this generator provides a dependable solution for anyone in need of backup power when it matters most.