3.4CLEAN AIR INTAKE

Clean all foreign material from the air intake (Figure 3.3) at least once every 100 hours of operation. Clean more often if necessary.

Inspect the area around the generator exhaust muf- fler periodically and remove all grass, leaves, dirt, etc., from this area.

Figure 3.3 – Cleaning Air Intake

USTC

3.5CHECKING THE ENGINE

SPARK PLUG

Clean the spark plug and reset the spark plug gap every 100 hours of operation.

1.Clean the area around the base of the spark plug to keep dirt and debris out of the engine. Remove the spark plug and check the condition. Replace the spark plug if worn or if reuse is question- able.

2.Clean spark plug by scraping or washing using a wire brush and commercial solvent. Do not blast the spark plug to clean.

3.Check the spark plug gap using a wire feeler gauge. Adjust the gap to 0.030 inch (0.76 mm) by carefully bending the ground electrode (Figure 3.4).

Figure 3.4 – Setting the Spark Plug Gap

3.6FUEL FILTER

Remove and replace the fuel filter (Figure 3.5) once each year or every 400 hours of operation, whichever comes first. Fuel filter is removed with a 15/16” deep well socket.

Figure 3.5 – Fuel Filter

POS

FUEL

NEG

3.7CLEAN SPARK ARRESTOR

The engine exhaust muffler has a spark arrestor screen. Inspect and clean the screen every 50 hours of operation or once each year, whichever comes first.

NOTE:

If using the generator on any forest-covered, brush-covered or grass-covered unimproved land, it must equipped with a spark arrestor. The spark arrestor must be maintained in good condition by the owner/operator.

Clean and inspect the spark arrestor as follows:

Remove the screen retaining bracket by removing the screw.

Slide the spark arrestor screen out from the tail pipe.

Inspect screen and replace if torn, perforated or otherwise damaged. DO NOT USE a defective screen. If screen is not damaged, clean it with com- mercial solvent.

Replace the screen and the retaining bracket.

Sparking can occur if the wire terminal does not fit firmly on the spark plug terminal end. If nec- essary, re-form the wire terminal to obtain a tight fit.

Figure 3.6 - Spark Arrestor

TAILPIPE

P/N 0E0683

SPARK ARRRESTOR

SCREEN P/N 089680

RETAINING

SCREW P/N 056892

13

Image 15
Contents Air-cooled Recreational Vehicle Generators Introduction Authorized Service Dealer LocationInside Front Cover Part II Installation Instructions Warning   Electrical Hazards  Model Generator IdentificationGenerator AC Connection System SafetySpecifications Generator Applicability‹ 1.5.6 Emissions Compliance Period ‹ 1.5.5 Generator‹ 1.5.2 Fuel Consumption ‹ 1.5.3 Engine OIL RequirementsBefore Starting the Engine Generator Control PanelOptional Remote START/STOP Panel Automatic Choke‹ 2.4.4 Cooling and Ventilating AIR Starting the Generator‹ 2.4.2 Engine Lubrication ‹ 2.4.3 Fuel SupplyStopping the Generator Do not Overload GeneratorProtection Systems ‹ 2.9.4 Overvoltage Protection Additional Information‹ 2.9.3 Field Boost ‹ 2.10.1 25-HOUR BREAK-IN Period‹ 2.10.5 Effects of Moisture and Dirt Checking the Engine OIL LevelChanging the Engine OIL AND/OR OIL Filter ‹ 2.10.4 Operation in High Grass or Brush‹ 3.3.1 Cleaning the Foam Precleaner Maintaining the Engine AIR CleanerFuel Filter Clean AIR IntakeClean Spark Arrestor Checking the Engine Spark Plug‹ 3.9.2 Every SIX Months Cleaning the GeneratorBattery Maintenance ‹ 3.9.1 Weekly‹ 3.12.2 Return to Service OUT of Service ProcedureAdjusting Valve Clearance ‹ 3.12.1 Removal from ServiceTightening Jam Nut RV Generator Service IntervalPart  General Hazards   Fire Hazards  Standards Booklets Purpose and Scope ManualEquipment Description Generator Engine Operating Speed0D8716 Location and Support ‹ 2.1.1 Generator Location‹ 2.1.2 Generator Support ‹ 2.2.1 Compartment Size Generator Compartments‹ 2.1.4 Generator Restraint ‹ 2.2.2 Compartment Construction‹ 2.2.3 Sound Insulating Materials ‹ 2.2.4 AcousticsView from TOP ‹ 2.2.5 Compartment Floor Cutouts‹ 2.3.1 Generator Airflow ‹ 2.3.2 Testing the Installation Cooling and Ventilating AIRGasoline Fuel System Rigid Fuel Lines Exhaust System‹ 2.4.1 Fuel Tank ‹ 2.4.2 Generator Fuel Supply Line‹ 2.5.2 Exhaust System Safety Electrical Connections‹ 2.5.1 Spark Arrestor ‹ 2.6.4 Conduit ‹ 2.6.2 Wiring‹ 2.6.1 Electrical Junction BOX ‹ 2.6.3 Generator AC Connections‹ 2.6.6 Power Supply Cord ‹ 2.6.5 Isolating Different Power Sources‹ 2.7.3 Battery Cable Connections Battery Installation‹ 2.7.1 Recommended Battery ‹ 2.7.2 Battery CablesBefore Initial START-UP Post Installation TestsTesting Under Load Initial StartInstallation Checklist Appendix 1 Notes Problem Cause Correction Troubleshooting GuideAppendix 3 Electrical Data Supplied by Customer To Carb Part NO. QTY Description 21 2 QTY Description 274 Regulator Voltage Appendix 4 Exploded Views and Parts Lists GUARD, FAN Appendix 4 Exploded Views and Parts Lists Long Block Assembly Your Warranty Rights and Obligations MANUFACTURER’S Emission Control System Warranty CoveragePURCHASER’S/OWNER’S Warranty Responsibilities Emission Related Parts Include the Following Emission Control System WarrantyWarranty Schedule CONSUMER/PERSONAL Applications

004700-00 specifications

Generac Power Systems is a recognized leader in the field of backup power generation, and one of its standout products is the Generac 004700-00. This reliable and high-performance generator has garnered attention for its robust features and advanced technological capabilities, making it an appealing choice for homeowners and businesses alike.

One of the key features of the Generac 004700-00 is its ability to deliver a reliable source of power during outages. With a powerful engine, this generator is designed to handle substantial loads, including sensitive electronics, heating systems, and appliances without compromising performance. The generator achieves this with a recommended horsepower rating that ensures a steady output even under heavy demand.

Incorporating Generac’s advanced Synch Power technology, the 004700-00 enables users to operate multiple devices simultaneously without any disruption. This feature ensures that the power provided is stable and consistent, minimizing the risk of damage to electronic devices during surges or fluctuations. Furthermore, the generator is engineered with a user-friendly control panel, making it easy to monitor performance metrics and adjust settings as necessary.

A standout characteristic of the 004700-00 is its quiet operation. Unlike many traditional generators, this unit utilizes noise-reducing technologies, ensuring that it operates at a lower decibel level. This feature is particularly beneficial for residential areas, where noise restrictions may be a concern.

The Generac 004700-00 also excels in fuel efficiency, allowing it to run longer on less fuel. This is achieved through its advanced engine design and efficient fuel consumption rate, which not only saves on operating costs but also reduces the environmental impact. Additionally, the generator is compatible with various fuel types, enhancing its versatility and convenience for users.

Ease of maintenance is another consideration with the 004700-00, as it is equipped with a maintenance alert system that notifies users when service is required. This proactive approach to care ensures that the generator remains in optimal working condition, prolonging its lifespan and reliability.

In summary, the Generac Power Systems 004700-00 stands out with its powerful performance, advanced technology, quiet operation, fuel efficiency, and user-friendly features. Whether for residential or commercial use, this generator provides a dependable solution for anyone in need of backup power when it matters most.