Generac Power Systems 004700-00 owner manual Installation Checklist

Page 35

Section 3 – Post-installation Start-up Adjustments

Recreational Vehicle Generator

3.5INSTALLATION CHECKLIST

‹EXHAUST SYSTEM

‹ LOCATION AND SUPPORT

Exhaust system complies with all applicable

codes.

Generator is properly located.

Exhaust system is properly and safely installed.

Generator is properly supported.

Generator is properly restrained.

‹GENERATOR COMPARTMENT

Compartment construction is proper.

Holes/Openings are vapor-sealed.

Compartment size is correct.

Compartment is vapor-sealed.

Sound insulation is correct.

Floor cutouts are properly completed.

‹COOLING AND VENTILATING AIR

Airflow is adequate.

Air inlet opening is correct.

Compensate for restrictions.

Check that installation has been tested.

‹GASOLINE FUEL SYSTEM

Fuel tank complies with all applicable codes.

Fuel system is properly installed and checked for leaks.

‹OPTIONAL LP GAS FUEL SYSTEM

Fuel system is properly installed and checked for leaks.

Pressure at regulator inlet is correct.

Rated flow of primary regulator is correct.

All parts are properly installed.

Fuel system is properly tested/adjusted.

‹ELECTRICAL CONNECTIONS

Connections comply with local code requirements and all National Electrical Codes.

Junction box is properly installed.

Wiring meets all standards.

All connections are correct.

Conduit is properly installed and sealed.

Generator is properly bonded to the vehicle.

‹BATTERY INSTALLATION

Recommended battery is installed.

Recommended cables are installed.

Cables are clean and tight.

Cables are connected properly.

Proper ventilation is provided.

Terminals are coated with anti-corrosion grease, and terminal covers are positioned.

‹OPTIONAL ACCESSORIES

Check that remote start/stop panels (if used) are installed properly.

Check that hourmeter kit (if used) is installed properly.

Check that any other options and accessories (if used) are installed properly.

‹POST INSTALLATION TESTS

Check that all tests are completed properly.

DATE OF INSTALLATION ____________________________________________________

NAME OF INSTALLER_______________________________________________________

SIGNATURE OF INSTALLER _________________________________________________

33

Image 35
Contents Air-cooled Recreational Vehicle Generators Introduction Authorized Service Dealer LocationInside Front Cover Part II Installation Instructions Warning   Electrical Hazards  Model Generator IdentificationGenerator AC Connection System SafetySpecifications Generator Applicability‹ 1.5.6 Emissions Compliance Period ‹ 1.5.5 Generator‹ 1.5.2 Fuel Consumption ‹ 1.5.3 Engine OIL RequirementsBefore Starting the Engine Generator Control PanelOptional Remote START/STOP Panel Automatic Choke‹ 2.4.4 Cooling and Ventilating AIR Starting the Generator‹ 2.4.2 Engine Lubrication ‹ 2.4.3 Fuel SupplyProtection Systems Stopping the GeneratorDo not Overload Generator ‹ 2.9.4 Overvoltage Protection Additional Information‹ 2.9.3 Field Boost ‹ 2.10.1 25-HOUR BREAK-IN Period‹ 2.10.5 Effects of Moisture and Dirt Checking the Engine OIL LevelChanging the Engine OIL AND/OR OIL Filter ‹ 2.10.4 Operation in High Grass or Brush‹ 3.3.1 Cleaning the Foam Precleaner Maintaining the Engine AIR CleanerFuel Filter Clean AIR IntakeClean Spark Arrestor Checking the Engine Spark Plug‹ 3.9.2 Every SIX Months Cleaning the GeneratorBattery Maintenance ‹ 3.9.1 Weekly‹ 3.12.2 Return to Service OUT of Service ProcedureAdjusting Valve Clearance ‹ 3.12.1 Removal from ServiceTightening Jam Nut RV Generator Service IntervalPart  General Hazards   Fire Hazards  Standards Booklets Purpose and Scope ManualEquipment Description Generator Engine Operating Speed0D8716 ‹ 2.1.2 Generator Support Location and Support‹ 2.1.1 Generator Location ‹ 2.2.1 Compartment Size Generator Compartments‹ 2.1.4 Generator Restraint ‹ 2.2.2 Compartment Construction‹ 2.2.3 Sound Insulating Materials ‹ 2.2.4 AcousticsView from TOP ‹ 2.2.5 Compartment Floor CutoutsGasoline Fuel System ‹ 2.3.1 Generator Airflow ‹ 2.3.2 Testing the InstallationCooling and Ventilating AIR Rigid Fuel Lines Exhaust System‹ 2.4.1 Fuel Tank ‹ 2.4.2 Generator Fuel Supply Line‹ 2.5.1 Spark Arrestor ‹ 2.5.2 Exhaust System SafetyElectrical Connections ‹ 2.6.4 Conduit ‹ 2.6.2 Wiring‹ 2.6.1 Electrical Junction BOX ‹ 2.6.3 Generator AC Connections‹ 2.6.6 Power Supply Cord ‹ 2.6.5 Isolating Different Power Sources‹ 2.7.3 Battery Cable Connections Battery Installation‹ 2.7.1 Recommended Battery ‹ 2.7.2 Battery CablesBefore Initial START-UP Post Installation TestsTesting Under Load Initial StartInstallation Checklist Appendix 1 Notes Problem Cause Correction Troubleshooting GuideAppendix 3 Electrical Data Supplied by Customer To Carb Part NO. QTY Description 21 2 QTY Description 274 Regulator Voltage Appendix 4 Exploded Views and Parts Lists GUARD, FAN Appendix 4 Exploded Views and Parts Lists Long Block Assembly PURCHASER’S/OWNER’S Warranty Responsibilities Your Warranty Rights and ObligationsMANUFACTURER’S Emission Control System Warranty Coverage Emission Related Parts Include the Following Emission Control System WarrantyWarranty Schedule CONSUMER/PERSONAL Applications

004700-00 specifications

Generac Power Systems is a recognized leader in the field of backup power generation, and one of its standout products is the Generac 004700-00. This reliable and high-performance generator has garnered attention for its robust features and advanced technological capabilities, making it an appealing choice for homeowners and businesses alike.

One of the key features of the Generac 004700-00 is its ability to deliver a reliable source of power during outages. With a powerful engine, this generator is designed to handle substantial loads, including sensitive electronics, heating systems, and appliances without compromising performance. The generator achieves this with a recommended horsepower rating that ensures a steady output even under heavy demand.

Incorporating Generac’s advanced Synch Power technology, the 004700-00 enables users to operate multiple devices simultaneously without any disruption. This feature ensures that the power provided is stable and consistent, minimizing the risk of damage to electronic devices during surges or fluctuations. Furthermore, the generator is engineered with a user-friendly control panel, making it easy to monitor performance metrics and adjust settings as necessary.

A standout characteristic of the 004700-00 is its quiet operation. Unlike many traditional generators, this unit utilizes noise-reducing technologies, ensuring that it operates at a lower decibel level. This feature is particularly beneficial for residential areas, where noise restrictions may be a concern.

The Generac 004700-00 also excels in fuel efficiency, allowing it to run longer on less fuel. This is achieved through its advanced engine design and efficient fuel consumption rate, which not only saves on operating costs but also reduces the environmental impact. Additionally, the generator is compatible with various fuel types, enhancing its versatility and convenience for users.

Ease of maintenance is another consideration with the 004700-00, as it is equipped with a maintenance alert system that notifies users when service is required. This proactive approach to care ensures that the generator remains in optimal working condition, prolonging its lifespan and reliability.

In summary, the Generac Power Systems 004700-00 stands out with its powerful performance, advanced technology, quiet operation, fuel efficiency, and user-friendly features. Whether for residential or commercial use, this generator provides a dependable solution for anyone in need of backup power when it matters most.