Generac Power Systems 004700-00 owner manual QTY Description

Page 43

 

 

 

 

Appendix 4 — Exploded Views and Parts Lists

 

 

 

 

 

 

 

 

 

 

 

 

Recreational Vehicle Generator

 

 

 

 

Generator – Drawing No. 0D8353-H

 

ITEM

PART NO.

QTY.

DESCRIPTION

 

1

050322

1

SCREW IHHC 5/16"-24 X 9-3/4"

 

2

022129

22

WASHER LOCK M8-5/16"

 

3

049451

1

WASHER FLAT .406" I.D. X 1.62" O.D.

 

4

0C8096A

1

FAN, 8" CURVE BLADE, 16.5MM I.D.

 

5

0D8120

4

SCREW IHHC M8-1.25 X 260MM

 

6

066849

2

SCREW HHTT M5-0.8 X 16

 

7

066386

1

ASSEMBLY, BRUSH HOLDER

 

8

0D4217

1

CARRIER, REAR BEARING

 

9

073159

1

BEARING

 

10

0D4484H

1

ROTOR

 

11

0D4430H

1

STATOR

 

12

0D4216

1

ADAPTOR, ENGINE

 

13

048614

4

SCREW HHC 5/16"-24 X 3/4"

 

14

0D2588A

1

GASKET, FRONT DIVIDER

 

15

022131

4

WASHER FLAT 3/8"-M10

 

16

027028

4

NUT LOCK HEX 5/16"-18 NYLON INSERT

 

17

0D6832

1

BRACKET, ENGINE MOUNTING

 

18

022145

18

WASHER FLAT 5/16"

 

19

030231

3

SCREW HHC 5/16"-18 X 1-1/2"

 

20

0C3168

1

5/16" SPECIAL LOCK WASHER

 

21

022259

10

NUT HEX 5/16"-18

 

22

0C8565

2

SCREW SHC M8-1.25 X 18MM

 

23

0D8048

4

VIBRATION MOUNT

 

24

083512

6

SCREW HHTT M8-1.2 X 16MM

 

25

0D6831

1

BRACKET, ALTERNATOR MOUNTING

 

26

029451

2.14'

TAPE ELEC. UL FOAM 1/8" X 1/2"

 

27

0D6918

1

DUCT, ALTERNATOR AIR

 

28

0D2558

1

GASKET, ALTERNATOR DUCT

 

29

087680

2

NUT WING M6-1.0

 

30

0D7530

1

STUD, M6-1.0 OFFSET

 

31

0D9723

1

ELEMENT, AIR FILTER

 

32

0D4511

1

PRECLEANER, AIR

 

33

0D8451

1

WASHER FLAT .281" I.D. X 1.50" O.D.

 

34

022097

1

WASHER LOCK M6-1/4"

 

35

0D7440

1

MUFFLER

 

36

090388

2

SCREW HHTT M6-1.0 X 12MM

 

37

0D7441

2

BOLT CARR 5/16"-18 X 2"

 

38

081105

2

NUT FLANG 5/16"-18 LOCK

 

39

089476

1

GASKET, EXHAUST

 

41

022531

1

SCREW HHC 5/16"-18 X 1-3/4"

 

42

0D8981

1

FILTER GASKET RV

41

Image 43
Contents Air-cooled Recreational Vehicle Generators Introduction Authorized Service Dealer LocationInside Front Cover Part II Installation Instructions Warning   Electrical Hazards  Model Generator IdentificationGenerator AC Connection System SafetySpecifications Generator Applicability‹ 1.5.6 Emissions Compliance Period ‹ 1.5.5 Generator‹ 1.5.2 Fuel Consumption ‹ 1.5.3 Engine OIL RequirementsBefore Starting the Engine Generator Control PanelOptional Remote START/STOP Panel Automatic Choke‹ 2.4.4 Cooling and Ventilating AIR Starting the Generator‹ 2.4.2 Engine Lubrication ‹ 2.4.3 Fuel SupplyDo not Overload Generator Stopping the GeneratorProtection Systems ‹ 2.9.4 Overvoltage Protection Additional Information‹ 2.9.3 Field Boost ‹ 2.10.1 25-HOUR BREAK-IN Period‹ 2.10.5 Effects of Moisture and Dirt Checking the Engine OIL LevelChanging the Engine OIL AND/OR OIL Filter ‹ 2.10.4 Operation in High Grass or Brush‹ 3.3.1 Cleaning the Foam Precleaner Maintaining the Engine AIR CleanerFuel Filter Clean AIR IntakeClean Spark Arrestor Checking the Engine Spark Plug‹ 3.9.2 Every SIX Months Cleaning the GeneratorBattery Maintenance ‹ 3.9.1 Weekly‹ 3.12.2 Return to Service OUT of Service ProcedureAdjusting Valve Clearance ‹ 3.12.1 Removal from ServiceTightening Jam Nut RV Generator Service IntervalPart  General Hazards   Fire Hazards  Standards Booklets Purpose and Scope ManualEquipment Description Generator Engine Operating Speed0D8716 ‹ 2.1.1 Generator Location Location and Support‹ 2.1.2 Generator Support ‹ 2.2.1 Compartment Size Generator Compartments‹ 2.1.4 Generator Restraint ‹ 2.2.2 Compartment Construction‹ 2.2.3 Sound Insulating Materials ‹ 2.2.4 AcousticsView from TOP ‹ 2.2.5 Compartment Floor CutoutsCooling and Ventilating AIR ‹ 2.3.1 Generator Airflow ‹ 2.3.2 Testing the InstallationGasoline Fuel System Rigid Fuel Lines Exhaust System‹ 2.4.1 Fuel Tank ‹ 2.4.2 Generator Fuel Supply LineElectrical Connections ‹ 2.5.2 Exhaust System Safety‹ 2.5.1 Spark Arrestor ‹ 2.6.4 Conduit ‹ 2.6.2 Wiring‹ 2.6.1 Electrical Junction BOX ‹ 2.6.3 Generator AC Connections‹ 2.6.6 Power Supply Cord ‹ 2.6.5 Isolating Different Power Sources‹ 2.7.3 Battery Cable Connections Battery Installation‹ 2.7.1 Recommended Battery ‹ 2.7.2 Battery CablesBefore Initial START-UP Post Installation TestsTesting Under Load Initial StartInstallation Checklist Appendix 1 Notes Problem Cause Correction Troubleshooting GuideAppendix 3 Electrical Data Supplied by Customer To Carb Part NO. QTY Description 21 2 QTY Description 274 Regulator Voltage Appendix 4 Exploded Views and Parts Lists GUARD, FAN Appendix 4 Exploded Views and Parts Lists Long Block Assembly MANUFACTURER’S Emission Control System Warranty Coverage Your Warranty Rights and ObligationsPURCHASER’S/OWNER’S Warranty Responsibilities Emission Related Parts Include the Following Emission Control System WarrantyWarranty Schedule CONSUMER/PERSONAL Applications

004700-00 specifications

Generac Power Systems is a recognized leader in the field of backup power generation, and one of its standout products is the Generac 004700-00. This reliable and high-performance generator has garnered attention for its robust features and advanced technological capabilities, making it an appealing choice for homeowners and businesses alike.

One of the key features of the Generac 004700-00 is its ability to deliver a reliable source of power during outages. With a powerful engine, this generator is designed to handle substantial loads, including sensitive electronics, heating systems, and appliances without compromising performance. The generator achieves this with a recommended horsepower rating that ensures a steady output even under heavy demand.

Incorporating Generac’s advanced Synch Power technology, the 004700-00 enables users to operate multiple devices simultaneously without any disruption. This feature ensures that the power provided is stable and consistent, minimizing the risk of damage to electronic devices during surges or fluctuations. Furthermore, the generator is engineered with a user-friendly control panel, making it easy to monitor performance metrics and adjust settings as necessary.

A standout characteristic of the 004700-00 is its quiet operation. Unlike many traditional generators, this unit utilizes noise-reducing technologies, ensuring that it operates at a lower decibel level. This feature is particularly beneficial for residential areas, where noise restrictions may be a concern.

The Generac 004700-00 also excels in fuel efficiency, allowing it to run longer on less fuel. This is achieved through its advanced engine design and efficient fuel consumption rate, which not only saves on operating costs but also reduces the environmental impact. Additionally, the generator is compatible with various fuel types, enhancing its versatility and convenience for users.

Ease of maintenance is another consideration with the 004700-00, as it is equipped with a maintenance alert system that notifies users when service is required. This proactive approach to care ensures that the generator remains in optimal working condition, prolonging its lifespan and reliability.

In summary, the Generac Power Systems 004700-00 stands out with its powerful performance, advanced technology, quiet operation, fuel efficiency, and user-friendly features. Whether for residential or commercial use, this generator provides a dependable solution for anyone in need of backup power when it matters most.