LP Gas Hook-Up
The heater comes equipped with a regulator/hose assembly for connection to a standard 20 lb. / 5 gallon LP gas tank (not included) and 18” tank strap to secure the tank within the base. A dented or rusty LP tank may be hazardous and should be checked by your LP supplier.
Never use an LP tank with a damaged valve. The LP tank must be arranged to provide for vapor withdrawal from the operating cylinder.
Never connect an unregulated LP tank to the heater. The heater is shipped from the factory for LP use, never substitute gases without first converting the heater with a factory supplied conversion kit. Conversion kits are available through customer service.
LP GAS CONNECTION-REFERENCE
The heater is designed to house a 20 lb. / 5 gallon gas cylinder in the base assembly. Open the door, and place the cylinder into the housing. The regulator can then be screwed into the cylinder. The regulator and the tank have
CHECK THE FOLLOWING CONNECTIONS
1)Regulator to gas cylinder.
2)All connections on the hose/regulator assembly.
3)The reducer fitting and the intake pipe.
4)Intake pipe fitting at base of safety valve. The remaining connections are to be tested after the heater has been lit. (See lighting instructions on page 13).
5)Pilot tubing to safety valve.
6)Orifice fitting and Safety valve.
7)Pilot tubing and the pilot. Once leak tested, close the door and replace the valve panel.
NOTE: Gas connections on the heater head assembly | FIG.07 | |
are leak tested at the factory prior to | ||
3 | ||
shipment. | ||
| ||
| 1 | |
| 2 |
GAS CYLINDER
(NOT INCLUDED)